Instruction/ maintenance manual of the product CH0142SQB (42") Kobe Range Hoods
Go to page of 36
KOBE Brand Range Hood Model No.: CH013 0SQB (30'') CH013 6SQB (36'') CH014 2SQB (42'') CH014 8SQB (48'') CH-101 SERIES – 18'' HEIGHT I N S T A L L A.
.
- READ AND S A VE THES E INSTRUC T IONS - CONT ENTS IMPORTANT SAFETY I NS TRUCTI ONS ... ..... .... ..... ..... ... ERROR! BOOKMA RK NOT DEFIN ED. COM PONENTS OF PA CKAG E ...............................................................................
1 IMPORT ANT SAFETY I NST RUCT IONS - PLEASE READ T HIS SECT I O N CAR EFUL L Y BEF ORE INST ALLA T ION - W ARNING: TO REDUCE T HE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJUR Y , OBSERVE THE F OLLO.
2 W hat to Do In The Event Of a Range T op Grease Fire • SMOTHER FLAMES w i th a cl ose fitting lid , cookie sheet, or m etal tray , a nd then tu rn off the burn er . KEEP F LAMMABLE O R COMBUST IBLE MA TERIAL A W A Y F ROM FLAMES. If the fl ames do not go ou t i mm edi ate l y , EV ACUA TE THE AR EA AND CALL THE F IR E DEP AR T MENT or 91 1.
3 COMPONENTS OF PA CKAGE (Must keep a ll materi al for returns or re funds) O P T I O N A L R E C I R C U L A T I N G K I T A L S O A V A I L A B L E . F O R M O R E I N F O R M A T I O N , P L E A S E V I S I T O U R W E B S I T E W W W . K O B E R A N G E H O O D S .
4 INS T ALLATION PLEASE READ ENTIRE INSTRUCT ION BEFORE PROCEEDING Calculatio n before Installat ion To cal culate installation , p l ea se refer to Table 1.
5 SAFETY WARN ING HOOD MA Y HA VE VER Y SHARP EDGES; P LEASE WEAR PROT ECTIVE GLOVES IF IT I S NECESSAR Y TO REMOVE ANY P A RT S FOR I NST ALLING , CLE ANING OR SERVICING . NOT E: BE C AREFUL WHEN USI NG ELECT RICAL SCREWDRIVER, D AMAGE TO THE HOOD MA Y OCCUR.
6 UNDER T HE CA B INE T INS T A LLAT ION Preparatio n Before Installat ion NOTE: TO AVOID DAM A GE TO YOUR HOOD, PREVE NT DEBRIS FROM ENTERING THE VENT OPENING. • De cide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
7 Ductwork Installat ion 7. Use 8” a luminum o r st eel p ipe ( fo llow bu ildi ng codes in your a rea) to c onnect the duct i ng transi tion on the hood to the ductwork above.
8 15. Inst all heati ng la mps (not pro vid ed), 120 Volt s 1 75 Watt s m ax. e ach. 16. Tu rn power ON in control panel. Ch eck all lights a n d fan operation.
9 ST AND A LO NE INST A LL ATION * * * F ol l o w th e se i ns t a l l a ti o ns o n l y i f i n s t a l l i n g wi t h a n o p t i o n al d u c t c o v e r : Preparatio n Before Installat ion NOTE : TO AVOID DAM AGE TO YOUR HO OD, PRE VENT DEBRI S FROM ENT ERIN G TH E VENT OP E NIN G.
10 2. Alig n hoo d -m ounti ng b rac ket to the two screw s on the wall and hook ho od in to pla ce. Tig hten scr ews to s ec u re hood t o t he wall . 3. For sa fety purp ose, extr a kno ckout hol e s on the back of the ho od are provi ded fo r a m o r e se cure inst all ati o n.
11 Duct Cover Installat ion 5. Use 8” a luminum or steel pipe ( f ollow b uilding codes i n y ou r area) to connect the ducting transition o n t he hood to the ductwork above . Use duct t ape to seal and secure joints as show n in Figu r e 15 . Sl i de t he du ct cover onto t he hoo d.
12 OPER A TING INSTRU CTIONS This KOBE h ood i s equipped with t ouch-sen sor s creen and fea tures 3 minute del ay shutoff, powerful centrifug al squirrel cage with b aff l e fil ters, brig ht 12-volt 20- watt hal ogen l i ghts a nd heatin g lam p cap abili ty (heating lam ps not i ncluded).
13 Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control s i g n o n c e , t h e symbol f l a shes and a f t e r 3 m i n u t e s , the ho o d w i l l t u r n o f f l e a v i n g o n l y t h e sign li t . Sp e e d C o n t rol : • There are f our speeds: QuietMode™, Low, M ed ium, and High.
14 M A INTEN A NCE SAFETY WARN ING NEVER PUT YOUR HA ND INTO AREA HOU SI NG T HE F AN WHILE T HE F A N I S OPERA TING . For opt imal op eration, clea n range hood and all baf fle/spacer/f i lter/oil tunnel /oil conta i ner regul arly . T o Cle an Hood Surface CA UT ION: NEVER USE ABRAS IVE CLEANERS, P A DS, OR CLOT HS.
15 T o Rep lace Light Bulb CA UT ION: HA LOGEN L IGHT UNIT MA Y BE HOT ! W AIT UNT IL UNI T IS COOL. 1. Make sure all controls are off, and range hood is unp lu gged. 2. Place a flat-head scre wdr i ve r between light cover an d housing to rem o ve cover .
16 SPECIFICA TIONS CH0130SQB / 30” CH0136SQB / 36” CH0142SQB / 42” M O DEL / S IZE CH0148SQB / 48” DESIGN 18-Gauge Seamless Commercial S tai n less S teel CONSUMPTI O N / AM PERE 702W / 5 .
17 ME A S UREMENTS & DIA G R A M S *** In c h measurements co nverted from millimete r. In c h meas urem e nts are e stimated. - F O R U N D E R T H E C A B I N E T - MODEL NO: CH013 0SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 / 8 " ( 7 9 .
18 - F O R U N D E R T H E C A B I N E T – ( C o n t . ) 2 - 5 / 8 " ( 6 6 ) 1 - 1 / 4 " ( 3 2 ) 6 - 1 / 2 " ( 1 6 5 ) 5 - 5 / 8 " ( 1 4 3 ) 1 0 - 3 / 4 " ( 2 7 3 ) 8 - 5 / .
19 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – MODEL NO: CH013 0SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " (4 5 7 ) 1 8 - 7 /8 " ( 4 8 0 ) 1 9 - 1 / 3 " (4 9 1 ) 1 - 1 / 4 " ( 3 2 ) 1 2 " ( 3 0 5 ) 6 " ( 1 5 2 .
20 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – (Con t.) 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " ( 4 5 7 ) 3 0 " ( 7 6.
21 Hood- Mounting Bracket 1" ( 2 5 .4) 4 " (1 0 2 ) 1 /2 " (1 3 ) 1 /3 " (8 . 5 ) 3 /1 6 " (5 ) 1/ 4" ( 6 .5 ) 1 1 /1 6 " (1 7 .
22 P A RTS LIST MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB BODY COMPONENT S NO. DESC RIPTION MOD EL/SIZE PART NO. 1 Hood Casi ng CH 101-1 2 Ducting Transiti on CH 101-2 3 Screw s (3/16” x 3/8.
23 1 2 3 4 5 9 3 8 1 0 1 1 6 1 2 1 3 1 4 1 7A 1 6 1 8 1 9 2 0 2 1 7 1 7B 1 7 1 5 2 2 2 3 Optional Duct Cover ( Sold Separately) 2 4 3.
24 Blower Assembly NO. DESCRIPTION MODEL / SIZE PART NO. 4.1 Screws (3/16 ” x 3/8”) CH101-4.1 4.2 Air Flow Grill CH101-4.2 4.3 Left Locknut CH101-4.3 4.4 Left Squirrel Cage CH101-4.4 4.5 Motor CH101-4.5 4.6 Ri ght Squirrel Cage CH101-4.6 4.7 Ri ght Locknut CH101- 4.
25 Electrical Assembly NO. DESCRIPTION M ODEL / SIZE PART NO. 21.1 Bolt CH101-21.1 21.2 Elect rical Box CH101-21.2 21.3 Screws (3/16” x 3/8”) CH101-21.3 21.4 Pow er Boa rd CH101-21.4 21.5 Elect rical Box Cover CH101- 21.5 21.6 Setup Boar d CH1 01-2 1.
26 Switch Assembly NO. DESCRIPTION MODEL / SIZE PART NO. 20.1 Screen Support CH1 01-2 0.1 20.2 Touch Scr een CH1 01-2 0.2 20.3 Sw i tch Box CH1 01-2 0.3 20.4 Sw i tch Boa rd CH101- 20.4 20.5 Sw i tch Box Cover CH1 01-2 0.5 20.6 Screw s (1/ 8” x 1/2”) CH101 -20.
27 CIRCUIT DIAGRAM MODEL NO.: CH0130SQB CH0136SQB.
28 MODEL NO.: CH0142SQB CH0148SQB.
29 DIS CL AIMER 1. CA R EFULL Y INS P ECT ALL ITEMS FOR DAMAGES B EFO RE ACCEPTING DELIVERY. NOT E A NY D A MAGES O N T HE F REI GHT BI L L OR EXPRESS RECEIPT. REQUES T NAME A ND SIGNATURE O F T HE CA RRIER’S AGENT A ND KEEP COPY T O SUPPORT YOUR CLAIM.
30 WA RRANT Y WA RRANT Y CERTIFICA T E KOBE Rang e Hoods, Inc. w arr ants all produc ts manufactur ed or sup plied by i t to b e free fro m defect s in w or km a nshi p and materi als.
31 h) for da m ag e by or resu l tin g from atte m pted repairs conducted by anyone o ther tha n our Aut horized Service Agent. 3) T he purchas er sh all be r espo nsible fo r an y expenses i n volved.
32 PRODUCT REGISTRA TION Regis ter Your Product! Any covere d failure occurrin g within t wo year s of original purch ase arising from defe ctive workmanship or m ate rial in m anu factur e will be r epaired o r at our option t he unit will be repla ced free of ch arge by an a uthorized KOBE Range Hoods Agent or KOBE Ran ge Hoods a s applicable.
KOBE Range Hoo ds 10505 Valley Blvd Suite # 302 El Monte , CA 91731 USA http:// www.KOB ERa ngeH oods.c om This KOBE hoo d i s made f or u se i n the USA and CANADA onl y . W e do not recomm end usi ng thi s hood ove rseas as t he pow er suppl y may not be com p ati bl e and may vi olate the el ectr i cal cod e of that country.
An important point after buying a device Kobe Range Hoods CH0142SQB (42") (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kobe Range Hoods CH0142SQB (42") yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kobe Range Hoods CH0142SQB (42") - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kobe Range Hoods CH0142SQB (42") you will learn all the available features of the product, as well as information on its operation. The information that you get Kobe Range Hoods CH0142SQB (42") will certainly help you make a decision on the purchase.
If you already are a holder of Kobe Range Hoods CH0142SQB (42"), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kobe Range Hoods CH0142SQB (42").
However, one of the most important roles played by the user manual is to help in solving problems with Kobe Range Hoods CH0142SQB (42"). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kobe Range Hoods CH0142SQB (42") along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center