Manual P/N 21008088 Rev. A 8/10 2531-7201-00 ATTENTION: Please take a few minutes to thoroughly read this user’s guide which should be saved for future reference and passed on to any subsequent owner.
Carbon Monoxide Alarm Procedure 1) Operate the Test/Reset button; 2) Call your emergency services (Fire Department or 911); 3) Immediately move to fresh air - outdoors or by an open door/ window. Do a head count to check that all persons are accounted for.
Welcome Note: Many times throughout this User’s Guide, we will refer to Carbon Monoxide as “CO”. This Kidde carbon monoxide (CO) alarm is an important part of your family’s home safety plan. This alarm has been designed and tested to detect CO buildup in a residential environment.
Important Warning Statements WARNING: This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure compliance with Occupational Safety and Health Administration (OSHA), commercial or industrial standards.
1. Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is a colorless, odorless and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxygen. Periodically review this alarm manual and discuss your CO alarm emer- gency procedure with all the members of your family.
1. Information About Carbon Monoxide Carbon Monoxide PPM Levels (model KN-COPP-B-LP with digital display only) Model KN-COPP-B-LP is equipped with a digital display that shows levels of CO (displayed in PPM – parts per million). Learn the difference between dangerous, high, mid and low levels.
1. Information About Carbon Monoxide roded or disconnected vent pipes, loose or cracked furnace exchangers. • Vehicles and other combustion engines running in an open or closed garage, attached or near a home. • Burning charcoal or fuel in grills and hibachis in an enclosed area.
1. Information About Carbon Monoxide Because carbon monoxide is a cumulative poison, long-term exposures to low levels may cause symptoms, as well as short-term exposures to high levels. This Kidde unit has a time-weighted alarm – the higher the level of CO present, the sooner the alarm will be triggered.
2. Product Features and Specifications Green, Power LED Red, Alarm LED T est / Reset Button Peak Level Button Di g ital Displa y Green, Power LED Red, Alarm LED T est / Reset Button WARNING: After seven (7) years from initial power up, this alarm will “beep” two times every 30 seconds to indicate that it is time to replace the alarm.
Recommended Installation Locations CO alarms should be mounted in or near bedrooms and living areas. It is recommended that you install a Kidde CO alarm on each level of your home. When choosing your installation locations, make sure you can hear the alarm from all sleeping areas.
Locations To Avoid IMPORTANT: Improper location can affect the sensitive electronic com- ponents in this alarm. To avoid causing damage to the unit, to provide optimum performance, and to prevent unne.
Battery Installation and Replacement To install or replace the batteries in this Kidde CO alarm, please perform the following steps. 1. Slide open the bottom cover to expose the battery compartment. 2. If replacing batteries, remove the old batteries and properly dispose of them as recommended by the battery manufacturer.
Mounting This CO alarm can be either wall mounted or placed on a tabletop. For wall mounting, follow these steps: 1. Remove back mounting plate from the alarm, place it in the desired location, and mark the location of the two holes needed on the wall 2.
Whenever the alarm is operating, the green Power LED flashes every 30 seconds to indicate the unit is monitoring for CO. If the alarm senses dangerous levels of CO, the red Alarm LED will flash and the alarm will emit an audible alarm pattern.
6. Model KN-COPP-B-LP (with digital display) Operating Characteristics The following table illustrates the possible digital displays, describes the audible alarm patterns, and the recommended actions to take.
– – 6. Model KN-COPP-B-LP (with digital display) Operating Characteristics Peak Level Memory (model KN-COPP-B-LP only) When the Peak Level button is pressed and held, the display shows the highest CO reading taken by the CO alarm since its last reset or power up.
8. Maintenance NOTE: This unit is sealed. The cover is not removable. Due to the loudness of the alarm, we suggest that you place your fingers over the sounder opening while testing your alarm. Caution: Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss.
8. Maintenance Move the CO Alarm to a remote location, to prevent possible damage or contamination of the sensor, prior to performing any of the following: • Staining or stripping floors or furniture, painting or wall-papering, • Using aerosols or adhesives WARNING: Reinstall the CO Alarm as soon as possible to assure continuous protection.
SEVEN YEAR LIMITED WARRANTY Warranty Coverage: The manufacturer warrants to the original consumer purchaser, that this product (except battery) will be free of defects in material and workmanship for a period of seven (7) years from date of purchase.
An important point after buying a device Kidde KN-COPP-B-LP (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kidde KN-COPP-B-LP yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kidde KN-COPP-B-LP - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kidde KN-COPP-B-LP you will learn all the available features of the product, as well as information on its operation. The information that you get Kidde KN-COPP-B-LP will certainly help you make a decision on the purchase.
If you already are a holder of Kidde KN-COPP-B-LP, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kidde KN-COPP-B-LP.
However, one of the most important roles played by the user manual is to help in solving problems with Kidde KN-COPP-B-LP. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kidde KN-COPP-B-LP along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center