Instruction/ maintenance manual of the product 240V Keating Of Chicago
Go to page of 23
KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Part # 000000 Electric Pasta 0107 09/07 CUST OM P AST A ™ SYSTEM ELECTRIC SER VICE MANU AL.
i This operating, installation, and service manual should be given to the user . T he operator of the Custom Past a ™ System should be familiar with the functions and operation of the cooker . T his manual must be kept in a prominent, easily reachable location near the Pasta System.
SECTION I SPECIFICA TIONS . . . . . . . . . . . . . . 1 SECTION II INST ALLA TION Shipment and T ransit . . . . . . . . . . . . . . . . . . . . . . . .1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 A. Placement . . . .
2 I INTRODUCTION GENERAL Keating Electric Custom Pasta ™ Systems are designed to give maximum production efficiency , delivering high quality food products.
• Keating Custom Pasta ™ Systems are intended for other than household use. • AL WA YS instruct new employees on proper pasta system operation. • A Custom Pasta System ™ should be operated ONL Y by properly trained personnel. • AL WA YS turn pasta system off each night.
4 POSITIONING The past a cooker must be no closer than 6" from any combustible material. When placed under an exhaust hood with a fire retardant system it must comply with ANSI/UL 507-(Latest Edition) and ANSI/NFP A 96- (Latest Edition).
5 In most cases the health department will not allow a direct connection between the cooker drain and the floor receptical. Contact your local health dep artment for specific information in your area.
6 procedures below for your model. NOTE : Use of sodium chloride during the cooking process will have a detrimental ef fect on the cooker tank and will void the warranty . OPERA TION OF THIS P AST A SYSTEM SHOULD BE LIMITED TO PERSONNEL WHO HA VE BEEN THOROUGHL Y TRAINED IN OPERA TING PROCEDURES.
7 3. Drain water from Pasta System. 4. Fill Pasta System vessel with water . See page 7 – Filling. UNDER NO CIRCUMST ANCES SHOULD THE P AST A SYSTEM BE LEFT UNA TTENDED DURING BOIL-OUT . TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR T O TURN OFF THE POWER IF W A TER DROPS BELOW HEA T TRANSFER TUBES.
8 contact s will open, the display will flash, and the audible alarm will sound. T o cancel the audible alarm, press any button. C. P AUSE FEA TURE T o pause a cycle in progress, press any button. The relay output contact s will open, the display will flash, and the countdown will p ause.
9 B. The W ater Auto-Fill and Low Water Safety Shut- Off Systems The water supply connection, located at the bottom rear of the Pasta System and marked water , is a standard 3 / 8 ” female pipe connection. The water pressure should be between 20-60 psi.
10 V SER VICE AND P ARTS INFORMA TION THE COOKER MUST BE DISCONNECTED FROM ITS POWER SOURCE OR SHUT DOWN A T THE BREAKER PRIOR TO SER VICE. AUTO-FILL SYSTEM The auto-fill system allows the automatic addition of water to the past a cooker during cooking or idle function.
11 COMMON PROBLEMS SOLUTIONS (FOLLOW IN SEQUENCE) W ater always filling 1. Clean sensors thoroughly with brush and vinegar . 2. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. 3. If filling persists, ground out the top sensor (if filling stops, replace sensor – Part #010212).
PROBLEM PROBABLE CAUSE SOLUTION Pasta Cooker has poor recovery or runs cold. a. Over-filling basket s. b.Thermostat out of calibration. c. Element is faulty . d. Thermost at is faulty . e. Cont actor is faulty . a. Don’t overfill basket s. b. Calibrate thermost at.
VII P ARTS LIST CUSTOM P AST A SYSTEM ELECTRIC CONTROL P ANEL ASSEMBL Y 13 ITEM # DESCRIPTION QTY P ART # 1 INDICA TING LIGHT , AMBER, POWER ON 1 031624 2 TOGGLE SWITCH– MAIN ON-OFF 2 004499 3 INDIC.
14 P ARTS LIST FOR CUSTOM P AST A SYSTEM ™ ITEM DESCRIPTION MODELS P ART # 14 18 20 24 1 HEA TING ELEMENT 220V 6500W 14" ONL Y 018668 3 1 HEA TING ELEMENT 18" & 20" ONL Y 004353 2.
15 P ARTS LIST FOR 14" DROP-IN CUSTOM P AST A SYSTEM DESCRIPTION QTY P ART# THERMOST A T DIAL PLA TE 2 034975 AMBER INDICA TING LIGHT 1 031624 GREEN INDICA TING LIGHT 2 010682 BLUE INDICA TING LI.
16 VIII WIRING DIAGRAMS 14" ELECTRIC P AST A 2-THERMOST A T WIRING DIAGRAM (WITHOUT TIMERS).
17 14" ELECTRIC P AST A WITH 138 TIMERS WIRING DIAGRAM.
18 18" & 20" ELECTRIC P AST A WITH 138 TIMERS WIRING DIAGRAM.
19 18" ELECTRIC P AST A 2-THERMOST A T WIRING DIAGRAM (WITHOUT TIMERS).
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pas.
KEA TI NG LI M ITE D W AR RANTY C AR D PLEASE C OM P LETE AN D MAI L A T O NC E–W AR RANTY IS N O T I N E F FE CT UNTI L CAR D IS R ETU R N E D W AR RANTY R EG I STRA TIO N IS ALSO AV AI LAB LE ON L.
An important point after buying a device Keating Of Chicago 240V (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Keating Of Chicago 240V yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Keating Of Chicago 240V - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Keating Of Chicago 240V you will learn all the available features of the product, as well as information on its operation. The information that you get Keating Of Chicago 240V will certainly help you make a decision on the purchase.
If you already are a holder of Keating Of Chicago 240V, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Keating Of Chicago 240V.
However, one of the most important roles played by the user manual is to help in solving problems with Keating Of Chicago 240V. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Keating Of Chicago 240V along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center