Instruction/ maintenance manual of the product DPG10002-01 Anaheim Automation
Go to page of 12
December 2004 DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack User’s Guide #L010167 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.
User’s Guide # L010167 DPG10002-01, DPG10003-01, DPG10004-01 Microstep Driver Pack Features • Integrated MBC10641, Power Supply, and Cooling Fan • 90-265 VAC Input • Output Current 10.
December 2004 # n i P n o i t p i r c s e D 1: ) + ( e d o n A t u p n I k c o l C p e t S e n o r o t o m e h t s e c n a v d a t u p n i d e t a l o s i s i h t n o e g d e g n i o g e v i t i s o p A . 1 h c t i w S f o s t u p n I t c e l e S p e t s o r c i M e h t n o t n e d n e p e d s i t n e m e r c n i e h t f o e z i s e h T .
User’s Guide # L010167 Absolute Maximum Ratings Input Voltage: 90-265 VAC Output Current: 10.0 AMPS PEAK Max Plate Temperature: 70° C Storage Temperature: 0° to +50° C Input Voltage (For isolated inputs): +5V to +24V at 2.5mA Optional: Non-Isolated +5VDC Output can power the MBC10641 Inputs (but isolation is eliminated).
December 2004 Optically Isolated Inputs The following inputs to the MBC10641 are Optically Isolated. To enable an input, apply a DC voltage source of +5VDC to +24VDC across the inputs. The Anodes (+) are pins 1,3,and 5 and the Cathodes (-) are pins 2, 4, and 6.
User’s Guide # L010167 Microstep Selection (SW1 Settings) Switches 2, 3 and 4, of the DIP switch select the number of microsteps per step. Table 7 shows the standard resolution values along with the associated positions for the select switches. The standard wave- forms are sinusoidal.
December 2004 Step Motor Selection Guide Anaheim Automation offers motor cable, making hook-ups quick and easy! Contact the factory or visit our website for more motor and cable offerings. TABLE 5 - Table Selection for Anaheim Automation Motor Current Settings.
User’s Guide # L010167 4 Lead Motors Multiply the specified series motor current by 1.4 to determine the current adjustment potentiometer value. Four Lead Motors are usually rated with their appropriate series current, as opposed to the Phase Current , which is the rating for 6 and 8 lead motors.
December 2004 8 Lead Motors Series Connection: When configuring the motor windings in series, use the per Phase (or unipolar) current rating to determine the current setting potentiometer value. Parallel Connection: When configuring the motor windings in parallel, multiply the per Phase (or unipo- lar) current rating by 2.
User’s Guide # L010167 Dimension Drawings DPG10002-01, DPG10003-01 and DPG10004-01 Micostep Driver Pack.
December 2004 COPYRIGHT Copyright 2001 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated .
User’s Guide # L010167 ANAHEIM AUTOMATION Torque Speed Curves.
An important point after buying a device Anaheim Automation DPG10002-01 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Anaheim Automation DPG10002-01 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Anaheim Automation DPG10002-01 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Anaheim Automation DPG10002-01 you will learn all the available features of the product, as well as information on its operation. The information that you get Anaheim Automation DPG10002-01 will certainly help you make a decision on the purchase.
If you already are a holder of Anaheim Automation DPG10002-01, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Anaheim Automation DPG10002-01.
However, one of the most important roles played by the user manual is to help in solving problems with Anaheim Automation DPG10002-01. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Anaheim Automation DPG10002-01 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center