Instruction/ maintenance manual of the product AXC-232++ AMX
Go to page of 20
instruction manual Axcess Control Cards AXC-232++ RS-232/422/485 Interface Card.
.
T able of Contents i AXC-232++ RS-232/422/485 Interface Card T able of Contents Introduction ............. ................ .......................................... ............................ ............ 1 Specifications .........................
ii AXC-232++ RS-232/422/485 Interface Card T able of Contents.
Intr oducti on 1 AXC-232++ RS-232/422/485 Interface Card Intr oduction Many audio visual and computer-based de vices can be remotely controlled using RS-232, RS-422, or RS-485 commands.
Introduction 2 AXC-232++ RS-232/422/485 Interface Card Specifications (Cont.) LEDs: RX/TX: Red LED indicators for data transmission RX: Red LED blinks to indicate that the AXC-232++ is receiving RS-232, RS-422, or RS-485 data. TX: Red LED blinks to indicate that the AXC-232++ is sending RS-232, RS- 422, or RS-485 data.
Installation and Wiring 3 AXC-232++ RS-232/422/485 Interface Card Installation and Wiring Setting the Internal J umper s The AXC-232++ can be used as an independent RS-232/422/485 -controlled in terface by setting the internal ju mpers (JP1 and JP2) .
Installation and Wiring 4 AXC-232++ RS-232/422/485 Interface Card Setting the RS-232/422 DIP Switch Set the stop bits, data bits, parity , and baud rate on the RS-232/422 DI P switch (see FIG.
Installation and Wiring 5 AXC-232++ RS-232/422/485 Interface Card Wiring De vices to the AXC-232++ Card Edge Pinouts The table belo w lists the card edge pinouts and the function of each. Preparing cap tive wires T o secure wires in a capti ve-wire connector: 1.
Installation and Wiring 6 AXC-232++ RS-232/422/485 Interface Card Using RS-422 When communicating via RS -422, connect the wiring as sho wn in FIG. 3. Using RS-485 When communicating via RS -485, connect the wiring as sho wn in FIG.
Installation and Wiring 7 AXC-232++ RS-232/422/485 Interface Card Replacing the Lithium Batterie s The AXC-232++’ s lithium batteri es ha ve a life of app roximately 5 yea rs to protect its memory . When DC power is on, the batteries are not used. When you install the AXC- 232++, record the date the batteries should be replaced.
Installation and Wiring 8 AXC-232++ RS-232/422/485 Interface Card.
Programming 9 A XC-232++ RS-232/422/485 Interface Card Pr ogramming Send_Commands The AXC-232++ supports the same com mand set as the AXC-232. Figure 20 l ists the AXC-232++ Send_Commands. AXC-232++ Send_Commands B9MOFF Sets data bit mode to normal with DIP switch settings (default).
Programming 10 AXC-232++ RS-232/422/485 Interface Card AXC-232++ Send_Commands (Cont.) CHARD Sets delay betw een all trans- mitted characters to incre- ment specified. Syntax: 'CHARD-<time>' Va r i a b l e : time = 100 microsecond increments 0 - 255.
Programming 11 A XC-232++ RS-232/422/485 Interface Card Axcess pr ogram c haracter istics The AXC-232++ is capable of running Axcess prog rams. It handles string processing, relieving AXlink and the AXC-EM of the processing times. AXC-232++ Send_Commands ( Cont.
Programming 12 AXC-232++ RS-232/422/485 Interface Card Send_String Escape Sequences The AXC-232++ does not regard certain three-character combin ations wi thin a Send_St ring program as literal characters, b ut as commands . The following table lists those combination s.
Programming 13 A XC-232++ RS-232/422/485 Interface Card AXC-232++ stat ements The Axcess program of the AXC-2 32++ communicates with the AX C-EM as Device 0. Its de vice communicates with the RS232/422 Input/Outpu t (I/O) of the AXC-232++ as Device 1.
Programming 14 AXC-232++ RS-232/422/485 Interface Card Xmodem Timing Commands The following table lists the AXC-232++ Xmodem timing commands. Xmodem timeouts exist to accommodate potential Ethernet delays and for consistency among and within products.
Programming 15 A XC-232++ RS-232/422/485 Interface Card Reserved Channels The follo wing table lists the channels reserv ed on Device 0. Axcess Master Mode When an Axcess device is placed in "Master Mode", the Central Controller’ s PR OGRAM port is moved to the Axcess de vice’ s RS-232 por t.
AMX reserves the right to alter specif ications without notice at any time. 031-004-173 7 9/05 © 2005 AMX Corporation. All rights reserved. AMX, the AMX logo, th e building ic on, the home icon, and the light bulb i con are all trademarks of AMX Corporation.
An important point after buying a device AMX AXC-232++ (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought AMX AXC-232++ yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data AMX AXC-232++ - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, AMX AXC-232++ you will learn all the available features of the product, as well as information on its operation. The information that you get AMX AXC-232++ will certainly help you make a decision on the purchase.
If you already are a holder of AMX AXC-232++, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime AMX AXC-232++.
However, one of the most important roles played by the user manual is to help in solving problems with AMX AXC-232++. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device AMX AXC-232++ along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center