Instruction/ maintenance manual of the product 13 SEER - GCGD Johnson Controls
Go to page of 16
Johnson Controls Unitary Produ cts 1031452-UIM-B-0513 R-22 OUTDOOR SPLIT -SYSTEM AIR CONDITIONING SHIPPED WITH NITROGEN CHARGE ONL Y MODELS: 13 SEER - GC GD 1.5 TO 5 T ONS INSTALLATION MANUAL ® LIST OF SECTIONS GENERAL . . . . . . . . . . . . . . . .
1031452-UIM-B-0513 2 Johnson Controls Unitary Products LIMIT A TIONS The unit should be installed in accordance with all National, S tate and Local Safety Codes and the limitations listed below: 1. Limitations for the indoor unit, coil, and appropriate accessories must also be observed.
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 3 LIQUID LINE FIL TER-DRIER The air conditioning unit’s copper spun filter/dryer is located on the liq - uid line.
1031452-UIM-B-0513 4 Johnson Controls Unitary Products Connect the refrigerant lines u sing the following proced ure: 1. Remove the cap and Schrader core from both the liquid and vapor service valve service ports at the outdoor unit. Connect low pres- sure nitrogen to the liquid line service port.
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 5 SECTION V : TXV INST ALLA TIONS The following are the basic steps fo r inst allation. For detailed instruc- tions, refer to the Installation Instructions accompanying the TXV kit. Install TXV kit as follows: 1.
1031452-UIM-B-0513 6 Johnson Controls Unitary Products SUPERHEA T CHARGING METHOD - PIST ON INDOOR 1. Operate system until temperatures and pressures stabilize (mini- mum of 10 minutes). 2. Measure and record indoor wet bulb (WB) temperature using a sling psychrometer and the outdoor dry bulb (DB) temperature using a thermometer .
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 7 FIELD CONNECTIONS CONTR OL WIRING 1. Route low voltage wiring into bottom of control box as shown in Figure 6. Make low voltage wiring conne ctions inside the low volt- age box per Figures 7 - 1 1.
1031452-UIM-B-0513 8 Johnson Controls Unitary Products For additional connection diagrams for a ll UPG equipment refer to “Low V oltage System Wiring” document available online at www .
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 9 FIGURE 9: Thermostat Chart - Single S tage AC with PSC Air Handler AC 1B Single Stage Air Conditioner – PSC Air Handler C 24 – Volt Comm on .
1031452-UIM-B-0513 10 Johnson Controls Unitary Products FIGURE 10: Thermostat Chart - Single S tage AC with PSC Furnace AC 5A Single Stage Air Conditioner – Single Stage PSC Furnace G*9F G*(8/9)S F*.
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 11 FIGURE 1 1: Thermostat Chart - Single S tage AC with PSC Furnace AC 5B Single Stage Air Conditioner – Single Stage PSC Furnace C 24 – Volt .
1031452-UIM-B-0513 12 Johnson Controls Unitary Products SECTION IX: INSTRUCTING THE O WNER Assist owner with processing warr anty cards and/or online registration. Review Owners Guide and provide a copy to the owner and guidance on proper operation and maintenance.
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 13 SECTION X: WIRING DIAGRAM FIGURE 12: Wiring Diagram.
1031452-UIM-B-0513 14 Johnson Controls Unitary Products NOTES.
1031452-UIM-B-0513 Johnson Controls Unitary Produ cts 15 SECTION XI: ST ART UP SHEET Air Conditioning and Heating Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity.
Subject to change without not ice. Published in U.S.A. 1031452-UIM-B-0513 Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 1031452-UIM-A-0413 Y ork Internat ional Corp. 5005 Y ork Driv e Norman, OK 73069 Supply static after indoor coil (in w.
An important point after buying a device Johnson Controls 13 SEER - GCGD (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Johnson Controls 13 SEER - GCGD yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Johnson Controls 13 SEER - GCGD - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Johnson Controls 13 SEER - GCGD you will learn all the available features of the product, as well as information on its operation. The information that you get Johnson Controls 13 SEER - GCGD will certainly help you make a decision on the purchase.
If you already are a holder of Johnson Controls 13 SEER - GCGD, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Johnson Controls 13 SEER - GCGD.
However, one of the most important roles played by the user manual is to help in solving problems with Johnson Controls 13 SEER - GCGD. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Johnson Controls 13 SEER - GCGD along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center