Instruction/ maintenance manual of the product 4 Aarrow Fires
Go to page of 28
Aarrow Fires Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain T el. (44) 01308 427234 Fax. (44) 01308 423441 www .aarrowfires.com Acorn Multifuel S toves Operating & Installation Manual PL.
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Acorn Multifuel to ensure ultimate performance and years of trouble free enjoyment.
INTRODUCTION Page Safety Notices 5 The Principle of the Fire 5 Check List 6 T echnical Data 7 INST ALLA TION Page General Precautions 8 Handling 8 Hearth 8 Combustible Materials 8 Air For Combustion 8.
W ARNING T O ALL MUL TIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE" OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE T O USE THESE FUELS WILL INV ALIDA TE THE APPLIANCE GUARANTEE IF IN DOUBT CONT ACT THE SOLID FUEL ASSOCIA TION TELEPHONE NUMBER 0800 600 000 www .
Acorn Multifuel S toves 5 INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted.
Inside the appliance you should find the following: 6 Acorn Multifuel S toves CHECK LIST Part Description & V isual Aid (not to scale) Acorn 4 Multifuel Quanity Part No. 1. Grate bars 5 2. Integral front brace/ reatainer 1 3. Throat plate 1 4. Flue spigot 1(4”) 5.
Acorn Multifuel S toves 7 TECHNICAL DA T A Room Min/Max Room Heater Only Output (kW) 1- 4.5 TECHNICAL DA T A Acorn 4 Multifuel Room Heater with Domestic Hot W ater with add in boiler type T ype 7 Max Output to Room (kW) Max Output to W ater (kW) 3 1.
8 Acorn Multifuel S toves INST ALLA TION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and W ales 2000 ref Approved Document J 2002 edition (issued by the DTLR).
FIREBOX LINER P ANELS The Acorn Multifuel stoves have reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them. •Remove the front brace retainer .
MUL TIFUEL GRA TE GRA TE The grates in the Acorn Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb".
FITTING THE FLUE OUTLET AND HOT PLA TE The flue outlet spigot is found inside the appliance. It is removed by turning clockwise. Smear a very thin layer of fire cement on the faces of the flue outlet and the blanking plate. Fit the outlet to the appliance in the desired position.
Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3.
Acorn Multifuel S toves 13 INST ALLA TION TYPICAL REAR FLUE OUTLET.
14 Acorn Multifuel S toves INST ALLA TION TYPICAL MET AL INSULA TED CHIMNEY SYSTEM T O BE INST ALLED TO THE CHIMNEY MANUF ACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULA TIONS AND BS7566 P TS 1-4 P LAN V IEW OF REGISTER PLA TE AND CLEARANCES FOR NON INSULA TED FLUES A is minimum clearance for non-insulated flue = 1.
ADD IN BOILERS Acorn 4 & 5 multifuel stoves offer the option of a slab boiler , which occupies the position of the rear firebox liner panels. Fitting: •Remove the fuel retainers, rear firebox liner panels and throat plate. •Knock out the blanking discs in the back plate corresponding to the terminals on the boiler .
16 Acorn Multifuel S toves INST ALLA TION INSTRUCTIONS The expansion tank should have a capacity of at least 7 % of the system's water capacity . The cold water feed pipe should be at least 22mm diameter . There must not be any shut off valves in the circuit.
Fig. 7 Fully Closed Fig. 8 Fully Open Even when all the slots are completely shut a "bleed" of secondary air will be maintained ensuring that inflammable gases are burnt off. DISASSEMBLE AIR W ASH The Aarrow air wash may be disassembled for cleaning or adjustment.
Fig. 1 1b fitting new glass •Replace the two lower retaining clips and nuts. •Replace the upper airwash cover and nuts. Do not over-tighten the nuts as damage may occur to the glass (Fig.
Appr oval does not cover the use of other fuels either alone or mixed with a suitable fuel listed above, nor does it cover instructions for use of other fuels. For latest details please r efer to Hetas website www .hetas.co.uk. Do not use Homefire (six sided) and smaller sizes than S tovesse, e.
In the morning •Open the air control fully until embers begin to glow brightly and place pieces of fuel on the fire until it is well established. W ARNING: When wood is burnt slowly in a closed appliance it produces moisture and tar, which will create condensation and deposits in the chimney .
Acorn Multifuel S toves 21 OPERA TING INSTRUCTIONS CLEANING Important; Under some circumstances soot can quickly build up on the throat plate and adjacent areas. The throat plate should be removed and checked monthly , and any debris stripped off. Similarly , clean the upper surface of the firebox.
22 Acorn Multifuel S toves FINAL CHECK LIST CHECKLIST Hearths, Fir eplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory , and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002.
Acorn Multifuel S toves 23 P AR TS LIST 1. Integral Front Brace/ Retainer AFS1 101 AFS1086 AFS001 AFS064 AFS008 AFS1 141 AFS009A 2. Throat Plate 3. Grate Bar 4. Hot Plate 5. Operating T ool 6. Ashpan 7. Flue Spigot Part Description V isual Aid (not to scale) Acorn 4 Part No.
24 Acorn Multifuel S toves P AR TS LIST 8. Liner Set AFS1090 AFS1092 AFS1094 AFS1095 AFS1096 AFS047 AFS1097 9. Side Liner 10. Back Liner Set 11 . Glass Replacement Kit Complete with Gasket 12. Glass Clips 13. Hinge kit Comprises 2 Hinges & 4 Fixings Per Set.
Acorn Multifuel S toves 25 P AR TS LIST 15. Fire Door Rope Kit Complete with Door Rope Glue. AFS048 AFS1 099 AFS1 100 AFS204 AFS997 16. Main Door Assembly Complete with Handle,Glass, Gaskets,Clips and Seal. 17. Comb with Extension 18. Fire Door Locking Assembly Including Fire Door Handle 20.
Guarantee Once again we would like to thank you for buying an Aarrow fire. When you buy an Aarrow Fir e, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want.
Should you have any questions about your Acorn Multifuel Stove that is not covered in this manual please contact your Aarrow retailer . Please keep all repair receipts safely . Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
FINAL F ACTOR Y CHECK LIST QUALITY FINISH PA R T S FLUE OUTLET HOT PLA TE FRONT INTEGRAL BRACE GRA TE FIREBOX LININGS THROA T PLA TE AIR W ASH DOOR CA TCHES ASH P AN OPERA TING TOOL OPERA TING INSTRUCTIONS Model.................................. Serial No.
An important point after buying a device Aarrow Fires 4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Aarrow Fires 4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Aarrow Fires 4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Aarrow Fires 4 you will learn all the available features of the product, as well as information on its operation. The information that you get Aarrow Fires 4 will certainly help you make a decision on the purchase.
If you already are a holder of Aarrow Fires 4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Aarrow Fires 4.
However, one of the most important roles played by the user manual is to help in solving problems with Aarrow Fires 4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Aarrow Fires 4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center