Instruction/ maintenance manual of the product PD30R-XXX-XXX-C Ingersoll-Rand
Go to page of 8
INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET – BRY AN, OHIO 43506 (800) 495-0276 y F AX (800) 892-6276 © 2010 CCN 15227655 www.ingersollrandproducts.com OPERA T OR’S MANU AL PD30R- XX X- XX X - C PE30R- XX X- XXX -C INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 2-4-05 REVISED: 11-17-10 (REV .
Page 2 of 8 PD30R-XX X-X XX-C (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause personal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pressure as sta ted on the pump model plate. Be sure material hoses and other componen ts are able to withstand uid pressures de veloped by this pump .
PD30R-XX X-X XX-C (en) Page 3 of 8 MAINTENANCE Refer to the part views and descriptions as provided on pages 4 through 7 for parts identi cation and service k it information. Certain ARO “Smar t Parts” are indicated which should be avail- able for fast repair and r eduction of down time.
Page 4 of 8 PD30R-XX X-X XX-C (en) P ARTS LIST / P X30R- XXX -X XX -C FLUID SECTION n 637303-X X Fluid section service k it includes: Balls (see Ball Option, refer to - XX in chart below), Diaphragms .
PD30R-XX X-X XX-C (en) Page 5 of 8 60 32 26 27 15 22 22 21 19 19 21 181 68 175 76 70 5 1 6 7 9 180 131 144 69 61 26 29 126 144 70 175 14 3 196 ) ASSEMBL Y T ORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS.
Page 6 of 8 PD30R-XX X-X XX-C (en) MA TERIAL CODE [B] = Nitrile [I] = Iron [Br] = Brass [P] = Polypropylene [C] = Carbon Steel [Sp] = Santoprene [Ck] = Ceramic [SS] = Stainless Steel [D] = Acetal [U] = P olyurethane AIR MO T OR SEC TION SERVICE Service is divided into two parts - 1.
PD30R-XX X-X XX-C (en) Page 7 of 8 P ARTS LIST / P X30R- XXX -X XX -C AIR MOT OR SEC TION Figur e 3 A replacement major valve service assembly is available separately , which includes the following: 6.
Page 8 of 8 PD30R-XX X-X XX-C (en) PN 97999-1111 C B D K A F E L H J M G N Outlet Inlet Exhaust Port 1-1/2 - 11-1/2 N.P .T . Air Inlet Ports 3/4 - 14 N.P .T .F . - 1 3 - 8 N.P .T .F . - 1 (PX30R-AXX -XX X-C) Rp 3 (3 - 11 BSP parallel) (PX30R-BXX -X XX-C) TROUBLE SHOO TING Product discharged from e xhaust outlet.
An important point after buying a device Ingersoll-Rand PD30R-XXX-XXX-C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PD30R-XXX-XXX-C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PD30R-XXX-XXX-C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PD30R-XXX-XXX-C you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PD30R-XXX-XXX-C will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PD30R-XXX-XXX-C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PD30R-XXX-XXX-C.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PD30R-XXX-XXX-C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PD30R-XXX-XXX-C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center