Instruction/ maintenance manual of the product 650110-X Ingersoll-Rand
Go to page of 8
CCN 81561318 OPERA T OR’S MANUAL 6501 10 - X INCLUDE MANUAL: S-632 GENERAL INFORMA TION MANUAL (PN 97999-624) SEE CHART BELOW 2” DIFFERENTIAL TRANSFER PUMP (CARBON STEEL) 6501 15 - X INCLUDING: OPERA TION, INST ALLA TION & MAINTENANCE READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR SERVICING THIS EQUIPMENT .
P a g e2o f8 6501 10-X GENERAL DESCRIPTION The ARO 2” differential, 2:1 ratio transfer pumps have been designed for the application and transfer of a wide range of corrosive and non-corro- sive materials. Refer to the lower pump parts list on page 4 for manufac- tured materials and packings available.
P a g e3o f8 6501 10-X 2” AIR MOTOR SER VICE PROCEDURES 2” AIR MOTOR DISASSEMBL Y R e f e rt oF i g u r e4 . NOTE: All threads are right hand. 1. Place the air motor in the vise with a needle valve or a 1/4” pipe nip- ple resting against the jaws of the vise, as shown.
P a g e4o f8 6501 10-X 60702 2’ ’ AIR MOTOR P ARTS LIST 1 2 3 4 5 6 8 9 10 11 12 13 14 15 17 18 19 20 21 22 16 7 93005 Ground Screw Figure 5 Item Description (size) Qty Part No. n Service Kit Parts 66098 1 Cap 1 76073-2 n 2 “O” Ring (3/32” x 2-5/16” o.
P a g e5o f8 6501 10-X LOWER PUMP SER VICE PROCEDURES LOWER PUMP DISASSEMBL Y R e f e rt oF i g u r e6 . NOTE: All threads are right hand. 1. Clamp the lower pump assembly in the vise on solid part of (28) pump body . CAUTION: Clamp the pump so that the three small tubes con - nected to the lower end of (28) pump body are not being twisted.
P a g e6o f8 6501 10-X LOWER PUMP END P ARTS LIST 24 25 26 27 28 29 30 31 32 33 s 34 50 38 39 40 41 42 43 44 45 46 47 48 49 (66198-X) 47 49 (66200-X) s Apply Loctite R 271 to threads. K Apply Loctite Nickel Anti-Seize to threads J Apply PTFE tape to threads.
P a g e7o f8 6501 10-X TROUBLE SHOOTING Pump continually cycles. • Check for empty material supply . Disconnect the air (from the pump) replenish material supply . • Check to see if the connecting rod has disassembled from the mat- ing rod. See assembly of lower pump end (figure 3).
P a g e8o f8 6501 10-X PN 97999-24.
An important point after buying a device Ingersoll-Rand 650110-X (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand 650110-X yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand 650110-X - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand 650110-X you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand 650110-X will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand 650110-X, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand 650110-X.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand 650110-X. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand 650110-X along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center