Installation Instructions Installation Instructions (In Toronto Area only: 1-905-3061093) Certified to comply with ASME A112.19.2M © 2008 AS America, Inc. NOTE TO INSTALLER: Please give this manual to the customer after installation. SELECTRONIC™ PROXIMITY URINAL FLUSH V AL VE 0.
Installation Instructions 1 1 2 3 4 5 6 7 8 9 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INST ALLATION IS COMPLETE. 5. Sweat Solder Adapter 6. Cover Tube 7. Wall Escutcheon 8. Supply Stop 9. Installation Instructions 1. Flush Valve Assembly 2.
Installation Instructions RECOMMENDED TOOLS; Fig. 2 Fig. 2 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Teflon Tape Flat Blade Screwdriver (For adjusting Supply Stop) Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch 2.
Installation Instructions 1 1 2 3 4 5 1 4 2 3 Fig. 4 Fig. 5 1. Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension “X”). Cut COVER TUBE (1) to length (X). Apply Teflon Tape to the threaded end of the Adapter or supply pipe.
Installation Instructions 4 M968567 Rev .1.2 1 CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2) . 2. With a flat blade screwdriver open SUPPLY STOP (2) . 3. Turn on water supply to flush line of any debris or sediment.
Installation Instructions M968567 Rev .1.2 5 7 9 6 10 2 5 8 1 121mm,+13mm, -6mm (4-3/4)(+1/2, -1/4) Fig. 8b Fig. 9 2 REMOVE COVER CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP IMP.
Installation Instructions M968567 Rev .1.2 6 Fig. 12b 3 9 1. Remove COVER (1) from SUPPLY STOP (2) if installed. Fig. 10. 2. Turn water supply off. Fig. 10. 3. Loosen SPUD COUPLING NUT (3) . Unthread COUPLING NUT (4) and VACUUM BREAKER COUPLING NUT (5) .
Installation Instructions M968567 Rev .1.2 HOW TO SET DETECTION RANGE (If Required) ; Fig. 13 6 6 3 Fig. 13b Fig. 13 Fig. 14 Fig. 14a Fig. 14b VIEW “A” 11 DETECTION ZONE 38mm TO 787mm (1-1/2 TO 31) 1 Fig.
Installation Instructions M968567 Rev .1.2 8 IS STOP VALVE OPEN? LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES INSTALL NEW BATTERY TRY MANUAL VALVE BUTTON; WILL THE UNIT FLUSH? NO REPLACE PISTON KIT IN.
Installation Instructions M968567 Rev .1.2 9 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 W eekdays 8:00 a.m. to 6:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) W eekdays 8:00 a.m. to 7:00 p.
An important point after buying a device American Standard Selectronic Proximity Urinal Flush Valve 6063.051 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Standard Selectronic Proximity Urinal Flush Valve 6063.051 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Standard Selectronic Proximity Urinal Flush Valve 6063.051 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Standard Selectronic Proximity Urinal Flush Valve 6063.051 you will learn all the available features of the product, as well as information on its operation. The information that you get American Standard Selectronic Proximity Urinal Flush Valve 6063.051 will certainly help you make a decision on the purchase.
If you already are a holder of American Standard Selectronic Proximity Urinal Flush Valve 6063.051, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Standard Selectronic Proximity Urinal Flush Valve 6063.051.
However, one of the most important roles played by the user manual is to help in solving problems with American Standard Selectronic Proximity Urinal Flush Valve 6063.051. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Standard Selectronic Proximity Urinal Flush Valve 6063.051 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center