Instruction/ maintenance manual of the product DO3637R Impulse
Go to page of 27
Rev F Date: 11.2.2006 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com READ AND SAVE THESE INSTRUCTIONS OPEN REFRIGERATED SELF-SE RVICE MERCHANDISE .
2 TABLE OF CONTENTS OVERVIEW AND WARNINGS ...………………………..…… ……………..…….………….....….. CUSTOMER CABINET PROVISIONS…… ……………..…………………..…….……… ….....….. CLEARANCE AND AIR FLOW .
3 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com OVERVIEW AND WARNINGS OVERVIEW • The Structural Concepts® Oasis® refrigerated self-service cases are designed to merchandise packaged products at 5° Celsius / 41° Fahrenheit or less product temperatures.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com CUSTOMER CABINET PROVI SIONS Customer Cabinet Provisions • Customer provided cabinet must adhere to the minimum requirements in ANSI/UL Std. 471 and ANSI/NSF Std.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com CLEARANCE AND AIR FLOW 5 Service Top Cutout Dimensions Note : See Manual Cover for DO3637R, DO4837R, DO3623R & 4823R Service Top Cutout Dimensions.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3637 R 6 BACK VIEW OF CABINET AFTER POSITIONED ON.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837 R 7 BACK VIEW OF CABINET AFTER POSITIONED ON.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO3623 R & DO482 3R 8 BACK VIEW OF CABINET AFTE.
2. Display Case Setup • SCC® Service Drop-In Refrigerated Merchan- diser Case consists of two sections: The Upper Display Case and Drop-In Refrigerated Section. • As both sections make up one conjoined unit, it is both large and heavy. A team effort is re- quired for lowering Case into the Customer Sup- plied Base.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com START-UP AND OPERATION Case Start-Up • Plug cord into a certified electrical outlet with ground. • Turn on the Main Power Switch. Switch is in the Drop-In Refrigerated Section on the rear right hand side of base.
Shelf Assembly Shelf Bracket 11 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com MAINTENANCE FUNDAME NTALS Adjustable Shelf • Adjustment of the angle of the shelves can be made by pivoting the lower portion of the shelf bracket in the upright.
12 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com MAINTENANCE FUNDAME NTALS, CONTINUED Warning, disconnect power before provid- ing maintenance and service to unit. As- sembly or disassembly and servicing to be accomplished by licensed electrical con- tractor.
13 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com MAINTENANCE FUNDAME NTALS, CONTINUED Removing the Rear Doors • Remove Thumbscrews (4 each side). Thumbscrew removal will allow Rear Doors to be removed.
14 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com REFRIGERATION FUNDAMENT ALS Refrigeration Access, Connections & Servicing Assembly or disassembly and servicing to be accomplished by licensed refrigeration contractor.
15 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com REFRIGERATION SLIDE-OUT EXPLODED PICTORI AL The following images show the various parts pertaining to the Refrigeration Unit (that is slid directly out from lower section) to be serviced.
16 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com TECHNICAL INFORMATION SHEET - MODEL DO3637R.
17 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com TECHNICAL INFORMATION SHEET - MODEL DO4837R.
18 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com TECHNICAL INFORMATION SHEET - MODEL DO3623R.
19 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com TECHNICAL INFORMATION SHEET - MODEL DO4823R.
20 TROUBLESHOOTING R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com Product is Drying Out Check the relative humidity in the store. Water on the Floor Check that all of the hoses are connected. Check that the drain trap is free of debris.
21 TROUBLESHOOTING, CONTINUED R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com Alarm Going Off, CPC ESC3 E0 flashing, Air probe has failed. E1 flashing, Defrost termination or product probe has failed.
22 CLEANING SCHEDULE R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com Cleaning Daily Weekly Monthly Task Clean Case Exterior X Clean outside surface of front curved glass with a household or commercial glass cleaner.
23 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com CPC® CONTROLLER - OVERVIE W Controller Overview The CPC ® ESC3 series is an electronic refrigeration controller that provides control of compressor, fan and defrost management.
R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com 24 CPC® - ESC3 CONTROLLER OPERATI ON Code Meaning E0 Air probe has failed. E1 Defrost termination or product probe has failed. L0 Low temperature alarm.
25 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com CPC ® ESC3 SET POINT CHAN GING INSTRUCTIONS Viewing and Changing the Temperature Set Point The temperature set point is the comparison point for the control temperature input.
26 WARRANTY R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com All sales by Structural Concept s Corporation (SCC) are subject to the following limited warranty. “Goods” refers to the product or products being sold b y SCC.
27 TECHNICAL SERVICE TECHNICAL SERVICE DEP ARTMENT 1.800.433.9489 R 888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.
An important point after buying a device Impulse DO3637R (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Impulse DO3637R yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Impulse DO3637R - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Impulse DO3637R you will learn all the available features of the product, as well as information on its operation. The information that you get Impulse DO3637R will certainly help you make a decision on the purchase.
If you already are a holder of Impulse DO3637R, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Impulse DO3637R.
However, one of the most important roles played by the user manual is to help in solving problems with Impulse DO3637R. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Impulse DO3637R along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center