Instruction/ maintenance manual of the product DSC CONTROLLER DS-100 Icom
Go to page of 36
INSTRUCTION MANUAL DS-100 DSC CONTROLLER.
i FOREWORD Thank you for purchasing this Icom product. The DS-100 DSC CONTROLLER is designed and built with Icom’s superior tech- nology and craftsmanship. With proper care this product should provide you with years of trouble-free operation. IMPOR T ANT READ ALL INSTRUCTIONS carefully and com- pletely before using the controller .
ii CAUTIONS R W ARNING! NEVER connect the controller to an AC outlet. This may pose a fire hazard or result in an electric shock. R W ARNING NEVER transmit a distress call when your vessel does not need immediate help. Distress calls can be used only in times of emergency .
iii FOREWORD ........................................................................ i IMPORT ANT ........................................................................ i EXPLICIT DEFINITIONS ...................................................... i FEA TURES .
1 1 P ANEL DESCRIPTION ■ Front panel q DISTRESS BUTTON Push and hold for 5 sec. to make a distress call. w CLEAR SWITCH [CLR] ➥ Push this key to cancel Call repeat. ➥ Push this key to cancel the menu. e CALL SWITCH [CALL] ➥ Push this key to call subject menu screen.
2 1 P ANEL DESCRIPTION must be set in advance. NOTE: If GPS data is interrupted for 30 sec. the “GPS” indi- cation disappears. The terminal unit retains the most recent data in such cases. ■ Function display q GPS INDICA TOR ➥ “GPS” appears while GPS receiver is connected.
2 CALL PROCEDURE 3 ■ Distress call/ Simple operation A distress call should be transmitted if, in the opnion of the Master , the ship or a person is in distress and requires imme- diate assistance. A distress call should include the ship’ s position and time.
CALL PROCEDURE 2 4 ■ Distress call/ Regular operation T ransmit a distress call after selecting the ‘Distress setting’. NEVER: USE THE DISTRESS CALL WHEN YOUR SHIP IS NOT IN AN EMERGENCY . DIS- TRESS CALL CAN BE USED ONL Y WHEN IM- MEDIA TE HELP IS NEEDED.
2 CALL PROCEDURE 5 NOTE: • ‘nature of distress’ will be recorded for 10 min. until a distress call transmits. • Distress call repeats every 3.5–4.5 min., until receiving an ‘ac- knowledgement’ • Beep (Pi,Pi) sounds with the max. volume every 1 sec.
CALL PROCEDURE 2 6 y Push UTC time with keypad. • Push [ Ω ]/[ ≈ ] to move the cursor then push [ Y ]/[ Z ] to correct the data • Push [CLR] to Exit the menu.
7 2 CALL PROCEDURE ■ Group call q Push [CALL], then push [ √ ] one or more times to select ‘Group call’, then push [ENT]. w Select the desired address, then push [ENT]. • Enter the 8 digit address when ‘Manual entry’ is selected. e Push [CALL] and [ENT] si- multaneously to transmit a ‘Group call’.
CALL PROCEDURE 2 8 D When no acknowledgement is received If no acknowledgement is received, the emergency alarm will sound continuously . In this case, the controller automatically tramsmits the distress call again every 3.5 to 4.5 minutes. • Push [CLR] if you want to stop the alarm.
9 3 WHEN RECEIVING A CALL ■ T o receive a DSC call D When receiving a DSC call Y ou should act in one of the following ways depending on the received DSC format (or category): • W ait for a voice transmission on the traffic frequency . • T ransmit an acknowledgement with DSC or voice.
■ When receive a Distress call D When receiving a Distress call When receiving a distress call, an alarm (Pi-po) sounds with max. AF level continuously . And at the same time, the trans- ceiver ’s (IC-M501EURO) oper- ating channel changes to CH 16 automatically .
WHEN RECEIVE A CALL 11 3 D When receiving an All ships call When receiving a Routine or Safety all ships call, an alarm (Pi-pi) sounds. When you receive a distress or Urgency all ships call, an alarm (Pi-po) sounds with max. AF level continuously . • Push [CLR] to cancel the alarm.
WHEN RECEIVING A CALL 3 12 D When receiving a Distress ACK When receiving a distress ac- knowledgement, an alarm (Pi- po) sounds with max. AF level continuously . And at the same time, the transceiver’s (IC- M501EURO) operating channel changes to CH 16 automati- cally .
13 3 WHEN RECEIVING A CALL ■ Received message (RCV MSG) When receiving a DSC call, the received format specifier and its contents are memorized into the received message (RCV MSG) memory . Distress calls (including other calls with dis- tress category) are stored separately from other calls.
3 14 WHEN RECEIVING A CALL D Other messages • Individual call q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘Individual call’, then push [ENT].
3 15 WHEN RECEIVING A CALL • All ships q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘All ships call’, then push [ENT]. • Push [ Y ] or [ Z ] to scroll the message.
16 3 WHEN RECEIVING A CALL • Distress relay acknowledgement q Push [CALL], then push [ √ ] several times to select ‘Re- ceived calls’, then push [ENT]. w Select ‘Other message’, then push [ENT]. e Select ‘Distress RL Y ACK’, then push [ENT].
17 4 SET -UP ■ Select ‘Set-up’ The following setting/operations available in ‘Set-up’ menu. • Address ID • Of fset time • Brightness • Contrast • MMSI check q Push [CALL], then push [ √ ] several times to select ‘Set- up’, then push [ENT].
4 SET -UP 18 • Delete address ID q Push [ √ ] to select ‘Delete address ID’, then push [ENT]. w Push [ ∫ ]/[ √ ] several times to select a desired address ID that you want to delete, then push [ENT]. • Address ID and name is dis- played on the screen.
4 SET -UP 19 ■ Offset time Local time can be used when the GPS position data is valid and off set time is input. q Push [CALL], then push [ √ ] one or more times to select ‘Set-up’, then push [ENT]. w Select ‘Offset time’, then push [ENT].
CONNECTION AND INST ALLA TIONS 5 20 t y q r e w IC-M501EURO DS-100 13.8V DC GND u ■ Connection diagram NOTE: Binding the GPS cable, GPS connector and clone receptacle with the water resistant tape, increases the water-proo fi ng of the controller .
5 21 CONNECTION AND INST ALLA TIONS ■ Rear panel description q CONNECTION CABLE Connets to the IC-M501EURO rear DSC controller recep- tacle. w RECEIVE ANTENNA CONNECTOR Connects a marine VHF receiving antenna with a PL-259 plug for emergency frequency signal receiving.
5 22 CONNECTION AND INST ALLA TIONS ■ Mounting The universal mounting bracket supplied with your controller allows dashboard or overhead mounting. Please read the fol- lowing instructions carefully . • Mount the controller securely with bolts and nuts or it may come loose as a result of wave shocks or vibration.
6 VHF MARINE CHANNEL LIST 23 Frequency (MHz) CH Frequency (MHz) CH T ransmit Receive T ransmit Receive 156.550 156.550 156.050 160.650 156.600 156.600 156.650 156.650 156.700 156.700 156.100 160.700 156.750 156.750 156.800 156.800 156.850 156.850 156.
24 7 SPECIFICA TIONS AND OPTIONS ■ Options MB-75 FLUSH MOUNTER For mounting the DS-100 to a panel. Available in black or white. CS-DS100 CLONING SOFTW ARE OPC-478 CLONING CABLE Allows quick and simple setting of vessel name, call sign, ID, etc. from a PC.
25 8 DIMENSIONS (Unit: mm) 165.0 84.4 110.0 31.4 53.0 25.0 145.0.
9 MB-75 (OPTION) 26 ■ MB-75 FLUSH MOUNT KIT The MB-75 is used to mount the DS-100 DSC CON- TROLLER fl ush to a fl at surface such as an instrument panel. • Supplied accessories Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 MB-75 27 e Using the 2 supplied bolts (M5 x 8 mm), attach the clamps on either side of the DS-100 as shown below . • Make sure that the clamps align parallel to the DS-100 ’ s body . r T ighten the end bolts on the clamps (rotate clockwise) so that the clamps press firmly against the inside of the in- strument control panel.
.
TEMPLA TE 164 (6 15 / 32 ) 149 (5 7 / 8 ) 16 ( 5 / 8 ) 92 (3 5 / 8 ) 4 – R11( 7 / 16 ) Unit: mm (inch) Cut here.
.
DECLARATION OF CONFORMITY We Icom Inc. Japan 6-9-16, Kamihigashi, Hirano-ku Osaka 547-0002, Japan Kind of equipment: DSC CONTROLLER This compliances is based on conformity with the following harmonised standards, specifications or documents: i) EN 301 025-2 V0.
Count on us! 6-9-16 Kamihigashi, Hirano-ku, Osaka 547-0002 Japan A-5654H-1EU- q Printed in Japan © 2000 Icom Inc. ‘ GER ‘ AUT ‘ GBR ‘ IRL ‘ FRA ‘ NED ‘ BEL .
An important point after buying a device Icom DSC CONTROLLER DS-100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Icom DSC CONTROLLER DS-100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Icom DSC CONTROLLER DS-100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Icom DSC CONTROLLER DS-100 you will learn all the available features of the product, as well as information on its operation. The information that you get Icom DSC CONTROLLER DS-100 will certainly help you make a decision on the purchase.
If you already are a holder of Icom DSC CONTROLLER DS-100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Icom DSC CONTROLLER DS-100.
However, one of the most important roles played by the user manual is to help in solving problems with Icom DSC CONTROLLER DS-100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Icom DSC CONTROLLER DS-100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center