1 Electronic/Mechanical Thermostat Model 40135 installation and operation manual 44017-01 04-01-2008.
2 Our T echnical Support Group is available from 8 am to 5 pm CST . They may be reached toll-free at 1-888-830-1326..
3 T able of Contents Important Information ....................................... 5 T ools ................................................................. 6 Uninstalling the Existing Unit ............................ 9 Installing the Thermostat ...
4 Congratulations! Thank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions.
5 This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boi.
6 This thermostat includes two #8 slotted screws and two wall anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ..........................................................................
7 NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection.
8 Y RC G W Y RC G W.
9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV AC system OFF at the main power panel or at the furnace. 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.
10 If your existing thermostat is marked... label the wire with this sticker: RH / R / VR / 4 RH RH 24 V olt RC / VC RC RC 24 V olt Cool Y / C* / M Y Y air conditioning compressor W / H W W heating G / F G G fan * See pg 27 for complete wiring diagram.
11 4. Using the provided stickers, label each wire according to the chart. (If the terminals are not labeled, contact a qualied HV AC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identication.
12 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the new thermostat from the back plate by pulling the two halves apart. Thermostat W all Plate.
13 W R C Y G.
14 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, level the wall plate and mark the wall for two holes.
15 RC RH Y G W.
16 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper .
17 HE/HG Switch.
18 A TT ACHING THE THERMOST A T 4. Locate the HE/HG s w i t c H on the back of the thermostat. Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.
19.
20 Fan Switch System Switch Set T emperature Slider Thermometer Battery Indicator SY STEM COOL OFF HE A T AU TO ON 3 0 2 0 1 0 9 0 8 0 7 0 6 0 5 0 F C 9 0 8 0 7 0 6 0 5 0 F.
21 OPERA TION 1. Set the s E t t E m p E r a t u r E s l i d E r to the desired temperature. 2. The s y s t E m s w i t c H determines the operating mode of the thermostat. Select c o o l , o f f , or H E a t . 3. The f a n s w i t c H should normally be located in the a u t o position.
22 INDICA T ORS AND ADUSTMENT 1. The t H E r m o m E t E r indicates the room temperature. 2. The B a t t E r y i n d i c a t o r displays two stages of battery conditions. The rst warning is the w E a k B a t t E r y w a r n i n G , indicated by the B a t t E r y i n d i c a t o r ashing once approximately every second.
23 Span Adjust SP AN.
24 INDICA T ORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o make your system run LONGER, turn the s p a n a d j u s t clockwise. 3. T o make your system run SHORTER, turn the s p a n a d j u s t counter clockwise. 4. Reattach the top cover to the thermostat.
25 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. W ait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit breakers and switches to ensure there is enough power to the system.
26 Is there help on the web? Y es. Visit http://www .hunterfan.com for more information. .................................................................................... ......... Can’t I just call someone? Sure. Our T echnical Support Group is available from 8 am to 5 pm CST .
27 G R h W Y F a n R e l a y H e a t / Co ol 2 4 V S u ppl y Co o l Co n t a c t o r H e a t R e l a y o r V a l v e 4 - w i r e H e a t / Co o l S y s t e m G Rc Rh F a n Re l ay He a t 24V Supply W .
28 WIRING DIAGRAMS R h W H e a t 2 4 V or M i l l i v o l t S u p pl y H e a t Re l a y o r V a l v e 2 - w i r e H e a t O n l y S y s t e m G R h W H e a t 2 4 V S u ppl y H e a t R e l a y o r V a .
29 G R c Y Co o l Co n t a c t e r Co ol 2 4 V S u ppl y 3 - w i r e Co o l O n l y S y s t e m F a n R e l a y WIRING DIAGRAMS, CONT ..
30 © 2007 Hunter Fan Company.
An important point after buying a device Hunter 40135 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hunter 40135 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hunter 40135 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hunter 40135 you will learn all the available features of the product, as well as information on its operation. The information that you get Hunter 40135 will certainly help you make a decision on the purchase.
If you already are a holder of Hunter 40135, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hunter 40135.
However, one of the most important roles played by the user manual is to help in solving problems with Hunter 40135. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hunter 40135 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center