Instruction/ maintenance manual of the product DL360e G8 HP
Go to page of 55
Essential features packed in a 1U footprint to deliver the key elements for file and print and single application workloads. Value, performance, flexible storage, enhanced management and superior serviceability makes the DL360e the 2P system right-sized for both SMB and enterprise customers.
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. Processor One of the following depending on Model Quad-Core Processors NOTE: All support up to 1066MHz DDR3 memory speeds.
Chipset Intel® C600 Series Chipset Intel® E5-2400 Processor Family NOTE: For more information regarding Intel® chipsets, please see the following URL: http://www.
http://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html NOTE: If only one processor is installed, only 6 DIMM slots are available. When populating with two processors 12 DIMM slots are available NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1600MHz, 1333MHz, or 1066MHz.
Storage Controller One of the following depending on Model Entry Model - SAS HP Dynamic Smart Array B320i Controller NOTE: Provides support for up to 8 SAS or SATA drives and includes SAS license key. Entry Model - SATA HP Dynamic Smart Array B120i Controller NOTE: Provides data transmission speeds up to 3Gb/s.
Interfaces Serial 1 Video 1 Front Mini-Video connector/ 1 Rear standard video (not active simultaneously) NOTE: Mini-video connector requires Front Video Adapter Kit (PN 655915- B21). HP iLO Remote Management Network Port 1Gb Dedicated SD slot 1 Internal secure NOTE: The SD slot is not a hot-pluggable device.
Common Slot Power Supply NOTE: Mixing of power supplies in the same server is not supported. All power supplies inside a server must be exactly the same model.
Operating Systems and Virtualization Software Support for ProLiant Servers Microsoft Windows Server Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Solaris VMware NOTE: For .
www.hp.com/go/intelligentprovisioning for additional information and to view usage videos. Use the Service Pack for ProLiant (SPP) at www.hp.com/go/spp to get firmware and software updates. HP iLO Mobile App: Enables the ability to access, deploy, and manage your server anytime from anywhere from select smartphones and mobile devices.
Security Power-on password Serial interface control Administrator's password Warranty This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase.
HP Insight Management HP Insight Control HP Insight Control, a product option, delivers essential infrastructure management that can help save time and money by making it easy to deploy, migrate, monitor, remote control, and optimize your IT infrastructure through a single, simple management console.
individual servers and dramatically faster updates of entire BladeSystem enclosures. Further improving system uptime and stability is the fact that HP provides 12 months of support on each Service Pack for ProLiant. The user experience around HP SUM and the SPP has been improved in several ways, starting with the web download.
HP HPC Linux Value Pack HP HPC Linux Value Pack (Value Pack) is an HP-licensed and HP-supported option to HP Insight CMU, bundle for the development and deployment of applications on HPC Cluster Platforms. Value Pack includes the Platform LSF workload scheduler and Platform Application Center, as well as the HP-MPI parallelization library.
Service and Support HP Technology Services for Industry Standard Servers and BladeSystem Capitalizing on HP ProLiant server and HP BladeSystem capabilities requires a service partner who understands your increasingly complex business technology environment.
Standard Care Standard Care: Service recommendation that maintains high level of server availability HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded.
HP Support Center Personalized online support portal with access to information, tools and experts to support HP business products. Submit support cases online, chat with HP experts, access support resources or collaborate with peers. Learn more http://www.
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. NOTE: Pre-configured models ship with the configurations below. Options can be selected from the Core or Additional options section of this QuickSpecs.
Entry Models - SATA Quad-Core SATA Model HP ProLiant DL360e Gen8 E5-2403 1P 4GB-R Hot Plug 4 LFF 460W PS Entry Svr 668812-001 Processor(s) (1) Intel® Xeon® E5-2403 (1.
Power Supply (1) HP 460W CS Gold Plus Hot Plug Power Supply (92% Efficient) Fans 4 Hot-Plug Non-redundant Fans Management HP iLO Management Engine (standard) Optional: HP Insight Control Form Factor Rack (1U) NOTE: Includes Rack Mounting Gen8 telescoping SFF Ball Bearing Rail Kit which does allow for in rack serviceability.
Warranty Server Warranty includes 3-Year Parts, 1-Year Labor, 1-Year Onsite support with next business day response QuickSpecs HP ProLiant DL360e Generation 8 (Gen8) Pre-configured Models DA - 14327 N.
HP ProLiant DL360e Gen8 E5-2403 1P 8GB-R Hot Plug 8 SFF 2x460W PS Server/S-Buy 686210-S01 Processor(s) Intel® Xeon® E5-2403 (1.8GHz/4-core/10MB/6.4GT-s QPI/80W, DDR3-1066, HT) Cache Memory 10MB (1x1.
HP ProLiant DL360e Gen8 E5-2420 1P 16GB-R Hot Plug 8 SFF 2x460W PS Server/S-Buy 686211-S01 Processor(s) Intel® Xeon® E5-2420 (1.9GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333, HT, Turbo2- 3/3/4/4/5/5) .
Management HP iLO Management Engine (standard) Optional: HP Insight Control Form Factor Rack (1U) NOTE: Includes Rack Mounting Gen8 telescoping SFF Ball Bearing Rail Kit which does allow for in rack serviceability. Due to the size and weight of the server two people are required to insall the server into the rack.
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on configurable product offerings and requirements.
Slot 1 - Full-Height/Half-Length (250mm) x 16 PCIe 3.0 Slot 2 - Low Profile x 8 PCIe 2.0 System Fans - 4 (4 additional fans included with second processor) USB - 4 Rear, 2 Front, 1 Internal 1 Internal.
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html (Worldwide) NOTE: HP memory from previous generation servers are not fully compatible with new Active Health features on the Gen8 Server.
HP Power Supplies NOTE: Mixing of power supplies in the same server is not supported. All power supplies inside a server must be exactly the same model.
Step 3: Choose Additional Factory Integratable Options HP Rack Kits NOTE: Gen8 rail kits have changed significantly from prior generation rail kits. Please take a moment to review the installation documentation that comes with the server to help you with the installation of your Gen8 server.
NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information. HP Processors NOTE: If two processors are desired, select the second from the xxxxxx-B21 below.
HP Memory NOTE: To realize the performance memory capabilities listed in this document, HP SmartMemory is required. For additional information, please see the HP SmartMemory QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.
HP Optical Drives HP 9.5mm SATA DVD-ROM JackBlack Optical Drive 652238-B21 HP 9.5mm SATA DVD-RW JackBlack Optical Drive 652241-B21 HP Hard Drives NOTE: The HP ProLiant Gen8 Smart Storage solutions are equipped with entirely re- designed Small Form Factor (SFF 2.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html (Worldwide) 6G SAS ME Hot Plug SFF (2.5-inch) Enterprise Mainstream Solid State Drives HP 800GB 6G SAS Mainstream Endurance SFF 2.
HP Networking Gigabit Ethernet Adapters HP NC112T PCI Express Gigabit Server Adapter 503746-B21 HP NC365T 4-port Ethernet Server Adapter 593722-B21 HP Ethernet 1Gb 2-port 361T Adapter 652497-B21 HP Et.
HP 750W Common Slot -48VDC Hot Plug Power Supply Kit NOTE: NOTE: The HP 750W Common Slot -48VDC power supply does not ship with a power cable. It has been designed with a terminal block connection allowing for custom design of power cords by the user.
NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator.
High Performance Clusters HP Cluster Management Utility HP Insight Cluster Management Utility 1yr 24x7 Flexible License QL803B HP Insight Cluster Management Utility 3yr 24x7 Flexible License NOTE: These part numbers can be used to purchase one certificate for multiple licenses and support with a single activation key.
HP Security HP Trusted Platform Module Option 488069-B21 NOTE: The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14227_na/14227_na.html (Smart Array P222 Controller) http://h18000.www1.hp.com/products/quickspecs/14228_na/14228_na.
HP Cable Options HP LC to LC Multi-mode OM3 2-Fiber 15.0m 1-Pack Fiber Optic Cable AJ837A HP B-series SFP+ to SFP+ Active Copper 1.0m Direct Attach Cable AP818A HP LC to LC Multi-mode OM3 2-Fiber 1.0m 1-Pack Fiber Optic Cable AJ834A HP LC to LC Multi-mode OM3 2-Fiber 30.
HP Modular Cooling System G2 HP Modular Cooling System G2 10642 G2 Expansion Rack AF026A HP Storage Options Fibre Channel HBA NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.
NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/14110_na/14110_na.html NOTE: For additional information on HP Uninterruptible Power Systems please go to: www.hp.com/servers/rackups . NOTE: For additional information on sizing your server, please reference: http://www.
HP Intelligent Power Distribution Units (iPDU) iPDU Core Units HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit AF520A HP 8.
HP Server Console Switches HP Server Console 0x2x8 Port Analog Switch AF616A HP Server Console 0x2x16 Port Analog Switch AF617A HP TAA 0x2x16xKVM Server Console G2 Switch AF626A NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.
allow for in rack serviceability. Due to the size and weight of the server two people are required to install the server into the rack. The HP 1U Gen8 Cable Management Arm is optional. To assist in the installation of the server into the rack an optional installation tool is available by contacting your local services representative.
HP 3 year 6 hour Call to Repair 24x7 w/ Defective Media Retention ProLiant DL360e Collaborative Sup U6D69E HP 3 year 6 hour Call to Repair 24x7 ProLiant DL360e Proactive Care Service U6D70E HP 3 year .
HP SmartMemory New HP SmartMemory now provides additional protection for your servers. With HP Authentication it can verify that you have true HP Qualified Memory in your HP ProLiant Gen8 server.
To realize the performance memory capabilities listed in this document, HP SmartMemory is required. For additional information, please see the HP SmartMemory QuickSpecs at: http://h18000.
Pre Configured Models Standard Memory Maximum Memory Plus Optional Memory Standard Memory Replaced with Optional Memory Intel Xeon E5-2430 24GB (6x 4GB) 120GB (6x 16GB, 6x 4GB) 384GB (12x 32GB) Intel .
Following are memory options available from HP: HP Memory NOTE: To realize the performance memory capabilities listed in this document, HP SmartMemory is required. For additional information, please see the HP SmartMemory QuickSpecs at: http://h18000.
A Optional DVD-ROM/DVD-RW 1-8 8 x SFF SATA/SAS/SSD Hot Pluggable Hard Drive Bays A Optional DVD-ROM/DVD-RW 1-4 4 x LFF SATA/SAS/SSD Hot Pluggable Hard Drives Bays External Storage Quantity Supported P.
System Unit Dimensions (H x W x D) 8 SFF 1.7 x 17.1 x 27.5 inches (4.32 x 43.46 x 69.9 cm) 4 LFF 1.7 x 17.1 x 29.5 inches (4.32 x 43.46 x 75.0 cm) Weight (approximate) Maximum (all hard drives, power supply, and processor installed) 8 SFF (17.14 kg) 4 LFF (17.
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment.
HP Dynamic Smart Array B120i Controller Dimensions Embedded Disk Drive Interface - Transfer rate Up to 6Gb/s SATA (Serial ATA) SATA Connectors 6 internal connectors w/hot plug support Server Interface.
HP Smart Array P420Controller Dimensions Low Profile PCIe Form Factor Disk Drive and Enclosure Interface - transfer rate 6Gb/s SAS (Serial Attached SCSI) 3Gb/s SATA (Serial ATA) SAS Connectors 2 internal 4X connectors Cache Memory Speed DDR2-800MHz with 40 or 72-bit wide bus Server Interface x4 PCIe 2.
Cable Support 10Base-T Categories 3, 4 or 5 UTP; up to 328 ft (100 m) 10/100/1000Base-TX Category 5 UTP; up to 328 ft (100 m) Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas.
An important point after buying a device HP DL360e G8 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP DL360e G8 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP DL360e G8 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP DL360e G8 you will learn all the available features of the product, as well as information on its operation. The information that you get HP DL360e G8 will certainly help you make a decision on the purchase.
If you already are a holder of HP DL360e G8, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP DL360e G8.
However, one of the most important roles played by the user manual is to help in solving problems with HP DL360e G8. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP DL360e G8 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center