Instruction/ maintenance manual of the product DL180 HP (Hewlett-Packard)
Go to page of 53
Front View: Rear View: 1. Access panel 1. Redundant Power Supply Bay (Optional) 2. Front LED Indicators 2. Power Supply Cable Socket 3. Power on/off 3. Low Profile Card Slot 4. Optional DVD-RW or DVD-ROM drive 4. PCI Expansion Card Slot 5. Front USB Ports (2) 5.
Up to 48GB, using PC3-10600E DDR3 Unbuffered (UDIMM) memory, operating at 1066MHz when fully populated at 2 DIMMs per Channel in 12 slots NOTE: Half DIMM slots are available when one processor is installed. Internal Drive Support : Support for up to twenty-five (25) SFF with a Smart Array controller.
support web site Expansion Slots : Up to Four (4) available PCI-Express Slots via the three (3) PCI-E Slot Riser One available Low Profile x16 PCI-Express slot using a Low profile Riser One 3PCI-E x8 .
Tool-less access to all system components for easy in rack serviceability Customer Self Repair (CSR): HP products are designed with many CSR parts to minimize repair time and allow for greater flexibi.
NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - Factory Integrated Models" section. Processor One of the following depending on Model Six-Core Processors Intel® Xeon® Processor X5670 (2.
performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
Expansion Slots Slot Number Bus Speed Bus Number * Device Number ** Hot Plug (Y/N) Notes 1 x16 PCI- Express 6 0 N Low Profile 2 x8 PCI-Express 5 0 N Full Length Full Height 3 x8 PCI-Express 4 0 N Full.
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade (P/N: 516471-B21) is required to enable RAID 6, 6+0 NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays (backplanes) and HP Smart Array controller up to date.
business. Advanced Licenses are required for Virtual KVM and Virtual Media feature activation. Key features of LO100 are: IPMI 2.0 & SMASH CLP support ROM Setup Utility Improvements to virtual media with the addition of USB 2.
While ProLiant 100 series G6 servers do not support the Insight Foundation Suite for ProLiant, they support a key subset of this important suite software tools and utilities which are very suitable fo.
HP Insight Diagnostics AutoRun Array Configuration Utility (ACU) has been combined with Array Diagnostics Utility (ADU) to offer both configuration of array controllers and storage devices and testing.
Security Power-on password Setup password Diskette boot control Secure Sockets Layer (SSL) Secure Shell (SSH) Security - Trusted Platform Module The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform.
Common Slot ProLiant It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers Power Supply Options: 460Watts, Common Slo.
Rack Kit HP ProLiant DL180 rack models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 26" - 36".
Service and Support HP services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded .
Four Drive Serial ATA (SATA) Models NOTE: Upgrading from 4 Non-Hot Plug SATA hard drives to 4 Hot Plug SATA/SAS hard drives requires the addition of a storage controller and one Internal mini-SAS cable (P/N 496013-B21).
Eight Drive Serial ATA (SATA) Models NOTE: Supports up to 8 Hot Plug SATA or SAS Hard Drives. HP DL180G6 E5620 2x4GB 8LFF 590638-xx1 Processor Intel® Xeon® Processor E5620 (2.
Form Factor Rack (2U) Twelve Drive Serial ATA (SATA) Models NOTE: Internal Storage expandable to 14 SAS/SATA drives with 2 Rear Drive Option Kit (P/N 488234-B21) HP DL180G6 E5620 2x4GB 12LFF US 590639-xx1 Processor Intel® Xeon® Processor E5620 (2.
Internal Storage 24.0TB (12 x 2TB Hot Plug 3.5" SATA hard drives), Maximum 24.0TB (12 x 2TB Hot Plug 3.5" SAS hard drives), Maximum NOTE: Internal Storage expandable to 14 SAS/SATA drives wi.
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) HP Processors NOTE: If 2 processors are desired, select one xxxxxx-L21 and one xxxxxxB21.
HP Memory Registered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500656-B21 HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 50065.
HP Power Supplies NOTE: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration.
NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additional information. HP Unique Options HP DL180G6 Redundant Fan Kit 516009-B21 HP DL180G6 Rear DVD Cage Kit NOTE: The x16 low profile slot is not available when this option is configured.
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 508343-B21 Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) 508342-B21 Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) 573909-B21 Intel® Xeon® Processor E5504 (2.
HP Optical Drives HP Slim SATA DVD-ROM Optical Drive 481041-B21 HP Slim SATA DVDRW Optical Drive 481043-B21 NOTE: Optical drives can be installed in front, on 4 & 8 bay hard drive models. NOTE: Optical drives can be installed in 12 and 25 drive model with the addition of rear option kit (P/N 515826-B21).
HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive 507632-B21 HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive 454146-B21 HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive 458928-B21 SATA Hot Plug LFF (3.
HP Entry-Level Server Management HP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: For additional License Kits please see the Lights-Out 100i QuickSpecs at: www.
HP I/O Accelerator Options HP 160GB SLC PCIe ioDrive NOTE: A low-profile PCI bracket is included for use in low-profile slots. NOTE: A minimum of 4 GB of system memory is required per card 600278-B21 HP 320GB MLC PCIe ioDrive NOTE: A low-profile PCI bracket is included for use in low-profile slots.
512MB BBWC NOTE: Supported on HP Smart Array P410 Controller and HP Smart Array P411 Controller only. 462967-B21 Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only.
HP InfiniBand Options QLogic IB 4X QDR PCI-e G2 Dual-port HC 583211-B21 HP IB 4X QDR CX-2 PCI-e G2 Dual Port HCA 592520-B21 HP IB 4X DDR CX-2 PCI-e G2 Dual Port HCA 592521-B21 NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.
HP Disk Backup NOTE: For the complete range of StorageWorks D2D Backup Systems see: http://www.hp.com/go/d2d . For the complete range of StorageWorks RDX drives and media see: http://www.hp.com/go/rdx . For hardware and software compatibility of HP StorageWorks disk backup products see: http://www.
HP U320e SCSI Host Bus Adapter NOTE: Recommended for MSL SCSI Tape Library connect. AH627A StorageWorks Converged Network Adapter HP CN1000E 2P Converged Network Adapter AW520A HP Disk Storage Systems.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.
HP Care Pack Services Hardware Services 4-Hour On-site Service 13-Hour x 5-Day Coverage, 3 Years, Electronic UH271E 24-Hour x 7-Day Coverage, 3 Years, Electronic UH272E Hardware Services Next Business.
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". HP ProLiant DL180 G6 Standard Memory (depending on model) 4GB (1 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed. 8GB (2 x 4GB) PC3-10600R-9 Registered memory, with Advanced ECC Capabilities Memory installed.
DIMM Type -> Registered DIMMS (RDIMMs) Unbuffered with ECC DIMMs (UDIMMs) DIMM Rank -> Single Rank (1R) Dual Rank (2R) Quad Rank (4R) Single Rank (1R) Dual Rank (2R) DIMM Capacity -> 4GB 2GB .
Standard memory configuration (1 CPU model) 6GB, consisting of three (3) 2GB dual-rank PC3-10600 RDIMMs CPU1 CPU2 slot # population order slot # population order Chnl 1 1 D: empty 1 D: empty Chnl 1 2 .
CPU1 CPU2 slot # population order slot # population order Chnl 1 1 D: 4GB DIMM 1 D: empty Chnl 1 2 A: 4GB DIMM 2 A: empty Chnl 2 3 E: 4GB DIMM 3 E: empty Chnl 2 4 B: 4GB DIMM 4 B: empty Chnl 3 5 F: 4G.
HP Memory Registered RDIMMs HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 500656-B21 HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit 50065.
8 Drive Cage with DVD-Drive bay 1-8 Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays 9 DVD-ROM, DVD RW 12 Drive Cage 1-12 Twelve 3.5" Hot Plug SAS/SATA Hard Drive Bays 13-14 Not Shown Two Rear 3.
SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives Quantity Supported Position Supported Controller 2TB 3G SATA 7.2K 1TB 3G SATA 7.2K 500GB 3G SATA 7.2K Up to 8 with 8 drive cage 1-8 HP Smart Array P21.
HP Smart Array P410/512 MB FBWC Controller HP Smart Array P410/1G FBWC Controller HP Smart Array P812/1G FBWC Controller HP Smart Array Hot Plug Advance Pack for B110i SATA Hot Plug 3.5" Midline (MDL) Solid State Drives Quantity Supported Position Supported Controller 60GB 3.
Quantity Supported Position Supported Controller 300GB 6G 10K SAS 146GB 6G 15K SAS 146GB 6G 10K SAS 72GB 6G 15K SAS Up to 8 with 8 drive cage 1-8 HP Smart Array P212/Zero Memory Controller HP Smart Ar.
External Storage Quantity Supported Position Supported Controller 60 Modular Smart Array Up to 4 External HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Arra.
LTO-2 Ultrium 448 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 LTO-5 Ultrium 3000 LTO-5 Ultrium 3280 1U Rack-Mount Kit 3U Rack-Mount Kit HP StorageWorks SCSI Tape Autoloaders, External DAT 72x10 Autoloader 1/8 G2 Autoloader External HP SC11Xe Host Bus Adapter Please check the full compatibility information at: http://www.
HP StorageWorks D2D Backup Systems, Fibre Channel D2D4000fc Rack Mount Direct server attach is not supported, requires connection via SAN fabric. See: http://www.
HP 460W Power Supply Part Number - AC 460W PSU 503296-B21 Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240 Maximum Rated Output Wattage 460 460 460 460 460 460 460 Nominal Input Current (A rms) 5.
HP 460W Platinum Power Supply Part Number - AC 460W PSU 593188-B21 Input Voltage Range (Vrms) 100 to 240 Frequency Range (Nominal) (Hz) 50/60 Nominal Input Voltage (Vrms) 100 120 208 200 220 230 240 Maximum Rated Output Wattage 460 460 460 460 460 460 460 Nominal Input Current (A rms) 5.
System Unit Dimensions (H x W x D) (with bezel) 3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm) Weight (approximate) Maximum (all hard drives, power supplies, and processors installed) 45.0 lb (16.80 kg) Minimum (one hard drive, power supply, and processor installed) 32.
(non-condensing) (82.4°F) maximum wet bulb temperature, non- condensing. Non-operating 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. Altitude Operating 3050 m (10,000 ft). This value may be limited by the type and number of options installed.
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive 458945-B21 160GB 7,200 rpm Capacity 160,041MB Height 1.04 in (26.4 mm) Width 4.36 in (110.7 mm) Depth 7.25 in (184.2 mm) Interface Serial ATA Transfer Rate (Maximum) 3Gb/s Native Command Queuing Supported Seek Time (typical reads, including settling) Single Track 2.
Smart Array P410/410i Controller Disk Drive and Enclosure Interface 6Gb/s SAS (Serial Attached SCSI) 3Gb/s SATA (Serial ATA) SAS Connectors 2 internal (Mini-SAS) x8 wide port connectors Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.
An important point after buying a device HP (Hewlett-Packard) DL180 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) DL180 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) DL180 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) DL180 you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) DL180 will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) DL180, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) DL180.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) DL180. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) DL180 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center