ProLiant BL30p Server Blades Installed in Server Blade Enclosure 1. ProLiant BL30p Server Blades (16) 2. ProLiant BL p-Class interconnects (2) (patch panel 2 shown) What's New ProLiant BL30p -- A.
At A Glance Maximum density ProLiant BL30p server blade Up to two Intel Xeon 3.2-GHz/533-MHz with 2MB L3 cache processors with Hyper-Threading Technology ServerWorks GC-LE chipset 1024-MB PC2100-MHz R.
ProLiant BL30p Server Blade + ProLiant BL30p Blade Sleeve (holds 2 BL30p blades) + QuickSpecs HP ProLiant BL30p Server Blade Overview DA - 11958 North America — Version 6 — September 24, 2004 Page.
BL p-Class Server Blade Enclosure with enhanced backplane components + OR Patch Panel (shown) or Patch Panel 2 GbE Interconnect Switch (shown) or GbE2 Interconnect Switch (fiber- or copper-based) BL p.
OR OR Mini bus bars Scalable bus bars Bus boxes BL p-Class power distribution Configuration Steps For a complete ProLiant BL30p blade solution, do the following: Select desired model, configuration and quantity of ProLiant BL30p server blades PLUS 1. Determine how many BL30p blade sleeves are required.
RJ-45 Patch Panel (230766-B21) or BL p-Class C-GbE2 Interconnect Kit (with 12 RJ-45 10/100/1000 T/TX/T external ports) (283192-B21) with or without optional ProLiant BL p- Class GbE2 Storage Connectiv.
ProLiant BL p-Class Server Blade Enclosures with Enhanced Backplanes Installed in 42U Rack Redundant Power Configuration (left) and Non-Redundant Power Configurations (right) 1.
Processor Intel Xeon Processor 3.2-GHz/533-MHz with 2MB L3 cache Intel Xeon Processor 3.2-GHz/533-MHz with 1MB L3 cache Intel Xeon Processor 3.06-GHz/533-MHz with 512KB L2 cache Upgradeability BL30p S.
Fiber Channel on the ProLiant BL30p The following items are needed to connect the ProLiant BL30p to a SAN via Fibre Channel: 1. ProLiant BL30p blade with Dual-Port Fibre Channel Adapter (option) insta.
ProLiant BL p-Class Server Blade Enclosure and Interconnects ProLiant BL p-Class Server Blade Enclosure 6U (10.5-inch), 19-inch wide Holds up to: Eight (8) ProLiant BL20p series server blades Sixteen .
ProLiant BL p-Class Interconnect Switch Option (A pair of switches per kit) (Each server blade enclosure requires a pair of interconnects - patch panels or interconnect switches) Interconnect Switch i.
ProLiant BL p-Class GbE2 Storage Connectivity Kit Option (supports a pair of GbE2 switches) The GbE2 Storage Connectivity Kit (option) is required for Fibre Channel signal pass-through when using a GbE2 Interconnect Switch Kit. Both Ethernet cable consolidation and Fibre Channel connectivity is possible using a single interconnect option.
Required Network Cabling 10Base-T Categories 3, 4 or 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) 100Base-TX Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) 1000Base-T Cate.
ProLiant BL p-Class Power System and Rack Information NOTE: To determine power configuration, please refer to the ProLiant BL p-Class Overview and Planning Whitepaper and sizing utility at http://www.hp.com/products/servers/proliant-bl/p-class/info/ .
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server ProLiant Essentials Rapid Deployment Pack Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers.
SmartStart SmartStart is a tool that simplifies single server setup, providing a rapid way to deploy reliable and consistent server configurations. SmartStart 7.00 and later can now deploy the ProLiant BL20P G3 and ProLiant BL40P servers, using the I/O port with an attached USB CD-ROM device.
ProLiant BL p-Class Availability Features Power redundancy: hot-plug power supplies redundant AC feeds (requires two power enclosures when using blade enclosures with enhanced backplane components) in.
Rack Airflow Requirements HP 10000 series racks provide enhanced airflow for maximum cooling, allowing racks to be fully loaded with servers and server blades using the latest server technologies.
ProLiant BL30p X3.2-2MB, 1GB (2P) 360329-B21 Processor(s) Two (2) Intel Xeon 3.2-GHz standard (up to 2 supported) Cache Memory 2-MB Level 3 writeback per processor Memory 1024-MB (standard) to 4-GB (m.
ProLiant BL30p X3.06/533MHz-512KB, 1GB (1P) 354050-B21 Processor(s) One (1) Intel Xeon 3.06-GHz standard (up to 2 supported) Cache Memory 512-KB Level 2 writeback per processor Memory 1024-MB (standar.
NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. Step 1: Base Server Blade Configuration Model HP Pro.
NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. Unique Options ATA Hard Drive Kit for ProLiant BL30p, 2.
Processor Intel Xeon 3.06-GHz / 512-KB cache Processor Kit (option) 354053-B21 NOTE: There is no option kit offered for the ProLiant BL30p with Intel Xeon 3.
BL p-Class Interconnects ProLiant BL p-Class Patch Panel 2 Kit with Fibre Channel pass-through (pair) 306465-B21 NOTE: Only one interconnect kit required per server blade enclosure. ProLiant BL p-Class Patch Panel (pair) 230766-B21 NOTE: Only one interconnect kit required per server blade enclosure.
ProLiant BL p-Class Power Distribution Scalable Bus Bar 240560-B21 Mini Bus Bar 240559-B21 Dual Power Input Kit for Mini Bus Bar 364565-B21 Power Bus Box 240562-B21 ProLiant BL p-Class Other Options D.
solution; reference current compatibility information at http:/www.hp.com/go/ebs HP StorageWorks MSL5030 Tape Library MSL5030, 1 drive, 30 slots, Ultrium 230, RM 301897-B22 MSL5030, 2 drive, 30 slots,.
Magneto-Optical Jukeboxes HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes 300mx, 2 drive, 32 slot jukebox C1150M 600mx, 4 drive, 64 slot jukebox C1160M 700mx, 2 drive, 76 slot jukebox C1170M NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.
Cluster Options ProLiant Cluster HA/F200 for Modular Smart Array 1000 252409-B24 NOTE: For additional information regarding the ProLiant Cluster for HA/F100, HA/F200 for Modular Smart Array 1000 please see the following QuickSpecs at: http://h18000.www1.
Rack 10000 Series (Graphite Metallic) HP S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 HP Rack 10647 (47U) Cabinet - Pallet 245160-B21 HP Rack 10647 (47U) Cabinet - Crated 245160-B23 HP Rack 106.
Service and Support Offerings (HP Care Pack Services) NOTE: The HP Care Pack services for ProLiant BL p-Class server blades, cover the server blade and the p-Class blade enclosure that the server blade is installed in as well as interconnects, power enclosure with power supplies and power distribution.
ProLiant BL30p Server Blade (all models) Standard Memory 1024-MB PC2100 MHz Registered DDR SDRAM DIMM installed (1 x 1-GB SDRAM DIMM) Standard Memory Replaced with Optional Memory Up to 4096-MB of DDR SDRAM DIMM memory is available with the removal of standard memory and the installation of optional SDRAM DDR DIMM memory expansion kits.
ProLiant BL p-Class Server Blade Enclosure with enhanced backplane components Dimensions Height 10.5 in (26.67 cm) Width 17.60 in (44.70 cm) Depth 28.86 in (73.
Operating and Performance Specifications for ProLiant BL p-Class RJ-45 Patch Panel Dimensions Height 10.405 in (26.43 cm) Width 1.535 in (3.899 cm) Depth 27.
Network Transfer Rate 10 Base-T (half-duplex) 10 Mbps 10 Base-T (full-duplex) 20 Mbps 100 Base-TX (half-duplex) 100 Mbps 100 Base-TX (full-duplex) 200 Mbps 1000 Base-TX (half-duplex) 1000 Mbps 1000 Ba.
Operating and Performance Specifications for ProLiant BL p-Class GbE2 Interconnect Switch Dimensions Height 10.405 in (26.43 cm) Width 1.535 in (3.899 cm) Depth 27.697 in (70.35 cm) Weight 12.0 lb/5.4 kg per interconnect switch Performance 24 Gbps External port bandwidth per server blade enclosure (full duplex) Forwarding rate 1.
Operating and Performance Specifications for ProLiant BL p-Class Power Enclosures Single-Phase Model 3-Phase Model Dimensions Height 5.25 in (13.34 cm) 5.25 in (13.34 cm) Width 27.15 in (68.96 cm) 27.15 in (68.96 cm) Depth 17.60 in (44.7 cm) 17.60 in (44.
Operating and Performance Specifications for ProLiant BL p-Class Power Distribution Devices Power Bus Box Mini Bus Bar Scalable Bus Bar Power Enclosures or facility DC feeds Supported (3U each) 1 1 or 2 1 or 2 Server blade enclosures supported (6U each) 1 up to 3 up to 5 Total rack height of supported enclosures 9U 24U 36U Dimensions Height 5.
Operating and Performance Specifications for Facility DC Voltage Nominal input voltage -48 VDC Operating voltage range -48VDC ± 10% or -43.2 VDC to -52.
An important point after buying a device HP (Hewlett-Packard) BL30p (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) BL30p yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) BL30p - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) BL30p you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) BL30p will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) BL30p, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) BL30p.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) BL30p. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) BL30p along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center