Instruction/ maintenance manual of the product DCM-750BAH(-OS) Hoshizaki
Go to page of 32
Hoshizaki “A Superior Degr ee of Reliability” www .hoshizaki.com Models DCM-750BAH(-OS) DCM-750BWH(-OS) Cubelet Icemaker / Dispenser Hoshizaki America, Inc.
2 IMPOR T ANT Only quali ed ser vice technicians should inst all, ser vice , and maintain the icemaker . No installation, service, or maintenance should be under tak en until the technician has thor oughly r ead this Instruction Manual.
3 CONTENTS Impor tant Saf et y Inf or mation ................................................................................................. 4 I. Specications .......................................................................................
4 Impor tant Safety Inf ormation Throughout this man ual, notices appear t o bring your at tention t o situations which could result in death, serious injur y , or damage to the unit. W ARNING Indicates a hazar dous situation which could r esult in death or serious injury .
5 MODEL NUMBER DCM-750BAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
6 MODEL NUMBER DCM-750BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4 HP FAN MOTOR 120V 1.0FLA 50W AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.
7 MODEL NUMBER DCM-750BWH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
8 MODEL NUMBER DCM-750BWH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1 COMPRESSOR 120V 10RLA 70LRA GEAR MOTOR 120V 3FLA 1/4HP FAN MOTOR ---- ---- ---- AGITATING MOTOR 12 0V 1 . 8F LA( TOT A L ) 110 W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.6A MAXIMUM FUSE SIZE 20 AMPS MAX.
9 B. Dimensions/Connections 1 . DCM-750B AH Unit: in. [mm].
1 0 2. DCM-750BAH-OS Unit: in. [mm].
1 1 3. DCM-750BWH Unit: in. [mm].
1 2 4. DCM-750BWH-OS Unit: in. [mm].
1 3 Unit: in. (mm) 5. DCM-750BAH(-OS) or DCM-750B WH(-OS) on optional SD-70 0 or SD-750 Stand SD-70 0 34" (864) SD-750 34" (864) 6-1/8" (1 56) SD-70 0 26-1/2" (673) SD-750 26-3/4&q.
1 4 II. Installation and Operating Instr uctions W ARNING 1 . This icemaker must be inst alled in accor dance with applicab le national, stat e, and local regulations . 2. CHOKING HAZARD: Ensure all components, f astener s, and thumbscre ws are secur ely in place af ter inst allation.
1 5 T op P anel Side P anel Side P anel F ront P anel Apron P anel Connect or s B. How t o Remo v e Panels See F ig. 1 or Fig. 2 • F ront P anel: Remo ve the scr e w . Lif t up and tow ards you. Disconnect the connect ors on push-but ton models. • T op P anel: Lif t up at front slightl y , push rearw ard and lif t of f .
1 6 C. Location C A UTION 1 . This icemaker is not int ended f or outdoor use. Nor mal operating ambient temper atur e should be within 45°F t o 1 00°F (7°C to 38°C); Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 7 E. Electrical Connection W ARNING 1 . Electr ical connection must be har d-wired and must meet national, st at e, and local electrical code requir ements. F ailure t o meet these code requir ements could result in death, electric shoc k, serious injur y , re, or e xtensiv e damage to equipment.
1 8 F . W ater Suppl y and Dr ain Connections See F ig. 4, 5, or 6 W ARNING 1 . W ater suppl y and drain connections must be installed in accor dance with applicable national, st at e , and local r egulations. 2. Nor mal operating wat er temperatur e should be within 45°F to 90°F (7°C to 32°C).
1 9 1 . Icemak er • Icemaker w ater suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the icemaker w ater supply line . • An icemaker w ater supply line shut-of f val v e and drain val ve should be installed.
20 Condenser W at er Supply Inlet 1/2" FPT Condenser Drain Outlet 3/8" FPT Icemaker W at er Supply Inlet 1/2" FPT Drip T ra y Drain Outlet 3/4" FPT 2. W at er -Cooled Condenser a) Connection to an Open Dr ain Sy stem • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT).
21 b) Connection to a Closed Loop S yst em • Condenser w at er suppl y inlet is 1/2" f emale pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended f or the condenser wat er supply line. • Condenser r etur n outlet is 3/8" FPT .
22 G. F inal Chec klist W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er installation. Make sur e that none hav e f allen into the stor age bin.
23 H. Star t up W ARNING 1 . All par ts are f act or y -adjusted. Improper adjustments ma y adv er sely af fect saf ety , performance, component lif e, and warranty cov erage. 2. If the icemaker is tur ned of f , w ait f or at least 3 minut es befor e restar ting the icemaker t o pre vent damage t o the compr essor .
24 F ig. 8 9) Disengage the saf et y s witch. Mov e the control s witch to the "OFF" position, then mov e the pow er s witch to the "OFF" position. T ur n of f the power suppl y . 1 0) Clean the st orage bin liner and the st orage bin cov er using a neutral cleaner .
25 III. Cleaning and Maintenance W ARNING CHOKING HAZARD: Ensure all components , fast eners, and thumbscr ews ar e securel y in place af t er any cleaning or maint enance is done to the unit. Make sure that none ha ve f allen into the st orage bin. A.
26 1 . W ater S yst em a) Cleaning Solution Dilute 9.6 . oz. (0.29 l) of Hoshizaki "Scale A wa y" with 1 .6 g al. (6.0 l) of war m w at er .
27 1 3) Af t er the gear mot or star ts, mo ve the contr ol s witch to the "DRAIN" position and allow the wat er sy st em to dr ain f or 5 minutes . Note: If you do not sanitiz e the unit, mo v e the contr ol s witch to the "ICE" position af ter the wat er sy st em drains .
28 c) Cleaning and Sanitizing Pr ocedure 1) Mov e the control s witch to the "OFF" position, then turn off the po wer supply . 2) Remo ve the fr ont and t op panels, then mo ve the po wer s witch to the "OFF" position. 3) Remo ve the st orage bin co ver .
29 B. Maintenance This icemaker m ust be maintained individuall y , ref erring to the instruction manual and labels pro vided with the icemaker . The schedule below is a guideline. More fr equent maintenance , howe ver , may be r equired depending on wat er qualit y , the icemaker's envir onment, and local sanitation regulations .
30 C. Pr eparing the Icemak er f or Long Stor age C A UTION When st or ing the icemak er f or an ext ended time or in sub-freezing temper atur es , f ollow the instructions below to pr ev ent damage.
31 4) At tach a compressed air or carbon dio xide supply t o the condenser water suppl y line drain v alv e . 5) Open the wat er regulating v al v e b y using a scr e w driver t o pr y up on the spr ing r etainer under neath the spring.
32 HOSHIZAKI AMERICA, INC. 618 Hwy . 74 S., Peachtree City , GA 30269 USA TEL (770) 487-2331 F AX (770) 487-3360 www .hoshizaki.com 91A2GE10B.
An important point after buying a device Hoshizaki DCM-750BAH(-OS) (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hoshizaki DCM-750BAH(-OS) yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hoshizaki DCM-750BAH(-OS) - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hoshizaki DCM-750BAH(-OS) you will learn all the available features of the product, as well as information on its operation. The information that you get Hoshizaki DCM-750BAH(-OS) will certainly help you make a decision on the purchase.
If you already are a holder of Hoshizaki DCM-750BAH(-OS), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hoshizaki DCM-750BAH(-OS).
However, one of the most important roles played by the user manual is to help in solving problems with Hoshizaki DCM-750BAH(-OS). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hoshizaki DCM-750BAH(-OS) along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center