Instruction/ maintenance manual of the product R7184B Honeywell
Go to page of 8
® U.S. Re gistered T radem ark Copyright © 2000 Honeywell Inc. • All Rights Reserved INSTALLATION I NSTRUCTIONS 69- 1233- 2 R7184A,B,P,U Interrupted Electronic Oil Pri mar y APPLICATION The R7184A.
R7184A,B ,P ,U INTER RUP TED ELE CTRONI C OI L PRIMAR Y 69-1233—2 2 Electric al Ratin gs: Inputs: V oltage: 102 to 132 V ac, 120 V ac nom i nal . Current: 100 mA plus burner motor, valve and ignitor loads . Frequency: 6 0 Hz. Outp uts: Relay Contacts: Burner: 120 V ac, 10 full load ampe res (FLA), 60 locked rotor amperes ( LR A).
R7184A ,B ,P ,U INTERR UP TED ELE CT RONIC OIL PRIM ARY 3 69-1233 — 2 CHECKOUT Start System WARNIN G Fire Hazard. Can cause ser i ous injury or death . Make su re combustion chamb er is free of oil and/or oil vapo r be fore st ar ting syst em. Fig. 2.
R7184A,B ,P ,U INTER RUP TED ELE CTRONI C OI L PRIMAR Y 69-1233 — 24 Fig. 5. T ypical wiring di agr am f or li ne vol t age Aquast at ® th er m ost at and R 7184 for an oil bu r ner system. Fig. 6. T ypical wiring di agra m for 24 Vac thermostat and R7184 fo r valv e- on del ay/bur ner mo t or off oi l burner sys tem.
R7184A ,B ,P ,U INTERR UP TED ELE CT RONIC OIL PRIM ARY 5 69-1233 — 2 1. Flashing at 1 Hz (1/2 secon d on, 1/2 second off): system is l ocked out or in r estricted mode. 2. Flashing at 1/4 Hz (2 secon ds on, 2 seconds off): control is in recy cle mode.
R7184A,B ,P ,U INTER RUP TED ELE CTRONI C OI L PRIMAR Y 69-1233 — 26 T able 4. R7184 O peration . Ext er nal Ac tion R7184 Ac tion Power appli ed to control . Internal safety che ck conduc ted. If no light or flame is detected and all int er nal conditions are corr ect , cont r ol en ters Id le m ode.
R7184A ,B ,P ,U INTERR UP TED ELE CT RONIC OIL PRIM ARY 7 69-1233 — 2 4. Shield cad cell from ex te rn al light . Indicator light tu rn s off. Eliminat e externa l light s ource or perman ently shi eld cad cell. Indicator light sta ys on. • Replace cad cell wi th new cad cel l and recheck.
69-1233 — 2 G.R. Rev . 5-00 www .hone ywell.com Home and Bu ilding Control Home and Bu ilding Control Honeywell Inc. Honeywell Limited-Honeywell Limitée Honeywell Plaza 155 Gordon Baker Road P.O. Box 524 North York, Ontario Minneapolis, MN 55408-0524 M2H 3N7 R7184A,B ,P ,U INTER RUP TED ELE CTRONI C OI L PRIMAR Y Printed in U.
An important point after buying a device Honeywell R7184B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honeywell R7184B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honeywell R7184B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honeywell R7184B you will learn all the available features of the product, as well as information on its operation. The information that you get Honeywell R7184B will certainly help you make a decision on the purchase.
If you already are a holder of Honeywell R7184B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honeywell R7184B.
However, one of the most important roles played by the user manual is to help in solving problems with Honeywell R7184B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honeywell R7184B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center