Instruction/ maintenance manual of the product MN12CES Honeywell
Go to page of 20
8 OWNER’S MANUAL Read these instructions before use Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Portable Air Conditioner Model: MN12CES / MN10CESWW Customer Support : 1-800-474-2147 For product inquiries or support : www.
THANK YOU..................................................................................................... INDEX .............................................................................................................. 1 2 3 4 6 7 13 15 16 USER TIPS.
Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner. Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside.
3 USER TIPS To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.
4 SAFETY WARNING READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance. DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent.
DO NOT run the power cord under carpeting and rugs. Use caution to prevent tripping on cord. DO NOT use in areas where gasoline, paint or other flammable goods are stored. Basic safety precautions should always be followed when using electrical appliances.
6 PARTS DESCRIPTION 1. Control Panel (Incl. Signal Receptor) 2. Air Outlet 3. Handle 4. Casters 5. Upper Drain Plug 6. Air Filter 7. Back Grill 8. Lower Drain Plug 9. Power Supply Cord 10. Exhaust Hose Connector 11. Remote Control 1 2 5 3 x 1 x 1 x 2 x 1 Installation Kit : 1.
7 INSTALLATION Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends. Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position.
Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly. 8 INSTALLATION 8 8 4 5 Connect the window bracket to the window.
The supplied exhaust hose can be extended from 12 inches (1 foot) to 47 inches (3.9 feet). Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off. The length of the exhaust hose is determined by the product specifications.
10 USE & OPERATION Touch Screen Control Panel Power Control Warning Light (when flashing) Mode Control Timer Control Timer / Temperature Set Controls Fan Speed Control After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
Note : Do not place the remote control in direct sunlight. Timer Control Temperature / Timer Set Mode Control Cool Dehumidify Fan In running mode: Auto switch off In stand-by mode: Auto switch on Press “ ▼ “ or “ ▲ “ button to adjust the time setting for 1 hour intervals.
Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with ‘‘+’’ and ‘‘-’’ pointing in the proper direction. • Use only two AAA or IEC R03 1.5V batteries. • Remove the batteries if the remote control is not in use for a month or longer.
13 CLEANING & MAINTENANCE Appliance Maintenance: 1. Turn off the appliance before disconnecting the power supply. 2. Always clean the appliance with a soft dry cloth. Air Filter Maintenance: The air filter should be cleaned every two weeks. Clean it as follows: 1.
When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (refer to page 10). This warning light indicates that the water condensation needs .
The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. 15 TROUBLESHOOTING GUIDE Will not run and water full indicator light is ON • No electricity.
TECHNICAL SPECIFICATIONS 16 Electrical products should be properly disposed. Please recycle where facilities exist. Check with your local authority or retailer for recycling.
17 SERVICE AND WARRANTY 5-YEAR LIMITED WARRANTY 1st year parts and labor. 5 years on all parts of the sealed system, consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. This warranty does not apply to any damage resulting from abusive, unreasonable use or damage.
SERVICE AND WARRANTY 18 Please read the Instruction Manual carefully before setting up or using this product. If you believe this product to be suffering from a manufacturing fault, or if you have inq.
MN12CES&MN10CESWW_IM_Eng_USA_10 January 2013 © 2013 AirTek Int’l Corp. Ltd. (JMATEK Int’l Group of Companies) The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product.
An important point after buying a device Honeywell MN12CES (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honeywell MN12CES yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honeywell MN12CES - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honeywell MN12CES you will learn all the available features of the product, as well as information on its operation. The information that you get Honeywell MN12CES will certainly help you make a decision on the purchase.
If you already are a holder of Honeywell MN12CES, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honeywell MN12CES.
However, one of the most important roles played by the user manual is to help in solving problems with Honeywell MN12CES. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honeywell MN12CES along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center