Instruction/ maintenance manual of the product EC-P2 Honeywell
Go to page of 28
Hone ywell EC-P2 Instruction Manual CHAR GE B A TT ER Y WHEN N OT I N US E Gas Detector EC-P2.
.
Honeyw ell EC-P2 Instruction and Installation Manual 3 Cop yright 2009 by Honeyw ell International Inc. Release J July 2008 While this inf or mation is presented in good f aith and belie ved to be acc.
Honeyw ell EC-P2 Instruction and Installation Manual 4 Introduction This manual has been prepared to help in the use of the Honeywell EC-P2 P ortable Gas Detector . This manual must be carefully followed by all individuals who have or will have the responsibility f or using or servicing this device.
Honeyw ell EC-P2 Instruction and Installation Manual 5 Introduction .................................................................................... 4 1 System Description ...........................................................................
Honeyw ell EC-P2 Instruction and Installation Manual 6 Data Logging with the Honeyw ell EC-P2: ............................... 18 W orking with the “EC-P2” program: ......................................... 19 4.5 Analog Output ...................
Honeyw ell EC-P2 Instruction and Installation Manual 7 1 System Description The Honeywell EC-P2 is a por table , batter y operated instrument for the measurement of gas concentrations in ambient air .
Honeyw ell EC-P2 Instruction and Installation Manual 8 System Specifications Primary Po wer: Alkaline D cell battery , 75 hours operation. Note: An audible alarm singl e beep ev er y 60 seconds indic ates th at eithe r the Alk aline D cell battery is lo w or the internal rechargeable NiCad batter y is low .
Honeyw ell EC-P2 Instruction and Installation Manual 9 The normal operating screen displays the inf ormation as shown in Figure 2 . The Honeyw ell EC-P2 is designed to avoid accidental shut-off of the power . T o turn the unit off, the PWR button must be held down for appro ximately three seconds.
Honeyw ell EC-P2 Instruction and Installation Manual 10 ME NU SM P L P PM N H 3 O FF 0 P A Power BA TTER Y I N USE P = Pr imar y (“D” cell ) S = S ta ndb y (In ter n al N iCad ) Flashi ng in dica .
Honeyw ell EC-P2 Instruction and Installation Manual 11 2.6 Interference Gases The Honeywell EC-P2 is generally quite specific to the target gas, but depending on the target gas, other gases ma y cause a reading. See Appendix B for a listing of potential interf erence gases for the v ar ious SMART -CELLs.
Honeyw ell EC-P2 Instruction and Installation Manual 12 3 Maintenance 3.1 P eriodic Maintenance It is esse ntial that the t est a nd ca librati on sc hedul e be adher ed to. Ho neywell Analytics recommends the f ollowing maintenance schedule: Response test prior to each use.
Honeyw ell EC-P2 Instruction and Installation Manual 13 Note: The unit may be zeroed without spanning it; however , never span the unit without rst zeroing it. The f ollowing procedure will calibrate the SMAR T -CELL. T o Enter ZER O / SP AN Mode Push power button to tur n unit on.
Honeyw ell EC-P2 Instruction and Installation Manual 14 External flowmeter indicates no flow: V er ify that pump is running. Check that the manif old screws are tight and the e xtension w and connection is tight. Unit does not respond when keys are pressed: Press and hold all four buttons f or fiv e seconds.
Honeyw ell EC-P2 Instruction and Installation Manual 15 4 Programming and Ad v anced Features 4.1 Alarm Setpoints, Functions The Honeyw ell EC-P2 has three adjustable alarm setpoints. These setpoints are stored on each SMART -CELL. The Caution setpoint is to w arn of excessiv e negative zero drift.
Honeyw ell EC-P2 Instruction and Installation Manual 16 W arning Function Push W ARN button. 4. Push FUNC (function) button. 5. Push SELECT button while viewing the arrow in the lower left hand cor ner 6.
Honeyw ell EC-P2 Instruction and Installation Manual 17 A V G V ariable Push A V G button. 5. Push INC button (increase) or DEC b utton (decrease) until the display 6. matches the desired value . Push SA VE button to store ne w A V G v ariable. 7. T o Exit A V G / BLANK Mode Push DONE button twice slo wly to get back into normal operation mode.
Honeyw ell EC-P2 Instruction and Installation Manual 18 Push the MORE button. 3. Push the SMPL (sample) button and the unit is no w in the SAMP / MEAS 4. / CLEAR mode. SAMP V ariable Push SAMP (sample) button. 5. Push INC button (increase) or DEC b utton (decrease) until the display 6.
Honeyw ell EC-P2 Instruction and Installation Manual 19 Push INT button (inter val) to cycle through the choices for how often to 5. log a data point. Stop when the desired interval is displayed. Notice how much time can be cov ered with the remaining free memor y .
Honeyw ell EC-P2 Instruction and Installation Manual 20 Each SMAR TCELL has a wide range of choices of full scale v alues. Note: The full scale range as programmed below only affects the analog output and the data logging full-scale output. The displa y will alwa ys cov er the entire operating range of the SMART -CELL.
Honeyw ell EC-P2 Instruction and Installation Manual 21 Appendix A A vailable SMAR T -CELLs Gas Min Range Max Range Resolution P art Number Alcohol 0-50 ppm 0-500 ppm 1 ppm 10167 Ammonia (NH 3 ) 0-50 ppm 0-500 ppm 1 ppm 10168 Ammonia (NH 3 ) 0-500 ppm 0-2000 ppm 1 ppm 10169 Bromine (Br 2 ) 0-1 ppm 0-5 ppm 0.
Honeyw ell EC-P2 Instruction and Installation Manual 22 BR 2 Cl 2 ClO 2 O 3 NH 3 CO H 2 O 2 NO H 2 S NO 2 SO 2 HCHO OH Fl 2 HCl H 2 O 2 Bromine ----- 1.0 1.0 0.7 -0.1 None None None None None 0.5 -0.1 None None 1.0 None None Chlorine 1.0 ----- 1.0 0.7 -0.
Honeyw ell EC-P2 Instruction and Installation Manual 23 Notes: None means there is no interf erence. 1. A number indicates that when exposed to the interf erence gas, the sensor 2.
Honeyw ell EC-P2 Instruction and Installation Manual 24 Limited W arranty 1. Ho ne yw el l An aly tic s Inc.. (“HA” ) w arr ants to the original purchaser and/or ultimate cust ome r (“P urc hase.
Honeyw ell EC-P2 Instruction and Installation Manual 25.
.
.
11385 Rev J July 2009 © 2009 Honeywell Analytics Find out more www .honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics 405 Barclay Boule vard Lincolnshire, IL 60069 USA T el: +1 847 955 8200 T oll free: +1 800 538 0363 F ax: +1 847 955 8208 detectgas@honeywell.
An important point after buying a device Honeywell EC-P2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honeywell EC-P2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honeywell EC-P2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honeywell EC-P2 you will learn all the available features of the product, as well as information on its operation. The information that you get Honeywell EC-P2 will certainly help you make a decision on the purchase.
If you already are a holder of Honeywell EC-P2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honeywell EC-P2.
However, one of the most important roles played by the user manual is to help in solving problems with Honeywell EC-P2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honeywell EC-P2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center