Instruction/ maintenance manual of the product CT3500/CT3595 Honeywell
Go to page of 24
69- 1199- 2 OWNER’S GUIDE ® U.S. Re g istered T rademark Cop y ri g ht © 2001 Hone y well • •All Ri g hts Reserved Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT Weekda y , Satu rda y and Sun.
69-1 199 — 22 Total comfort temperature m anagement with Smart Response ™ T ec hno l ogy . Con g ratulations! Y ou made a smart choice b y purchasin g y our new Hone y well thermostat the smart th.
3 69-1 199 — 2 Time Set Program Run Program Hold Temp Set Current Day/Time Day Heat/Cool Settings System Fan Wake Leave Return Sleep Heat Off Cool On Auto M18589 RAISES TEMPERATURE SETTING LOWERS TE.
69-1 199 — 24 M18590 Aux Ht System Off Auto WakeLeaveReturnSleep Mon Wait In Room Humid Outdoor Filter AM Hold for Repl Batt Recovery Cool Tue WedThuFriSatSun Days Set Program Set Day/Time Temporary.
5 69-1 199 — 2 STEP 1. PREPARE FOR INSTALL ATI ON ❑ Check T able 1, the compatibilit y cha rt, to mak e sur e the the rmos tat is comp atib le wi th y our s y stem. If y our s y stem is not compatible, call Hone y well Customer Relations Center , to ll-free, 1-800-468-1502.
69-1 199 — 26 STEP 2. REMOVE OLD THERMOSTAT ❑ T e st y our heatin g and coolin g s y stem s to mak e sure the y work properl y . If either s y stem does not work, contact y our local heatin g /air-conditionin g dealer . T o avoid compressor dama g e, do not operat e the coolin g s y stem when outdoor temperature is below 50 ° F (10 ° C).
7 69-1 199 — 2 Replacing a The rmostat th at has Thre e Wires If y ou have three wires for a heatin g onl y s y stem and c an operate the fan us in g the fan O N switch this thermostat works with y our s y stem. However , some hot water (zoned) heat in g s y stems also have three wires.
69-1 199 — 28 STEP 4. WIRE WALLPLATE TERMINALS IMPORT ANT All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air-conditioning contractor . Refer to the labels y ou placed on the wires when y ou removed th e old thermostat ( see illustration).
9 69-1 199 — 2 T able 2. T erminal Designations on Old and New Thermostats a If both RH and R t erminals are present on existin g thermostat, remove jumper and connect Rh to R and R to Rc. b Do not connect both O and B when wirin g to a sin g le sta g e heat pump.
69-1 199 — 21 0 ❑ If the thermostat is alread y mounted on the wall, remove the thermostat b y placin g y our thumb between the thermostat and wallplate and pullin g the thermostat up and awa y as shown. When the batteries are runnin g low , a REPL BA T messa g e flashes for one to two months before the batteries run out completel y .
1 1 69-1 199 — 2 STEP 7. MOUNT THE THERMOSTAT STEP 8. CUSTOMIZE YOUR THERMOSTAT Y our Hone y well thermostat comes preset to the most commonl y used settin g s. The set tin g s are: — Gas or oil fo rced air furna ce. — Smart Response techno lo gy on.
69-1 199 — 21 2 System Type (Feat ure Number 4) S y stem t y pe options are: — 1 = Gravit y or steam s y stem. — 3 = Hot water , hi g h effi cienc y furnace (90% or better), or sin g le sta g e heat pump. — 6 = Gas o r oil forced air furnace (preset).
13 69-1 199 — 2 Time Format ( Feature Number 16) T ime format options are: — 0 = 12-hour clock (preset). — 1 = 24-hour clock. T o chan g e time form at: ❑ Press once. ❑ Press to return to main displa y . Factory Set F unction (Feature Num ber 37) Do not chan g e this sett in g .
69-1 199 — 21 4 STEP 10. PROGRAMMING The ke y board is located behind the thermostat cover . The three most frequentl y used ke y s are near the displa y . Pressin g displa y s the current temperature settin g s. Pressin g the and ke y s chan g e the temperature.
15 69-1 199 — 2 T able 3. Persona l Pr ogrammin g T able. a Y our heatin g setpoints cannot be hi g her than 90 ° F (32 ° C) or lower than 40 ° F (4. 5 ° C). b Y our coolin g setpoints cannot be hi g her than 99 ° F (3 7 ° C) or lower than 45 ° F (7 ° C).
69-1 199 — 21 6 The setpoint temperature r an g e is 40 ° F to 90 ° F (4.5 ° C to 32 ° C) for heati n g and 45 ° F to 99 ° F (7 ° C to 37 ° C) for c oolin g . ❑ Press to switch between he atin g and coolin g setpoints. NOTE: Pro g ram tim es are the same for heatin g and coolin g .
17 69-1 199 — 2 STEP 11. OPERATING Y OUR THERMOSTAT Change Temperatu re Setting Un til the Next Program Per iod (Temporary Chan ge) ❑ Press or until the screen show s the desired temperat ure settin g . NOT E: The te mp or ar y temperature settin g is displa y ed for about 3 seconds a nd then the room tem perature is dis- pla y ed.
69-1 199 — 21 8 STEP 12. SET THE FAN AND SY STEM SWI TCHES First set the fan switch. Fan On: The fan runs continuousl y . Use for improved air circulation or for more efficient central air cleanin g . (In a heat-onl y s y stem, fan run s continuousl y onl y if fan rela y is connected to the G thermostat t erminal).
19 69-1 199 — 2 IF YOU HAVE A PROBLEM T able 4. S olution Guide. If... T hen… Dis pl a y does not a ppear . • Make sure the batteries are installed correctl y . • Make sure the thermostat is mounted and latched on the wallplate. Mount and latch the thermostat on the wallplate if it is not.
69-1 199 — 22 0 Toll-Fr ee Customer As sistan ce Please read and f ollow the provided instructions f or this thermostat. For additional information, g o to www . hone y wel l. co m/ y ourhome or call the Hone y well Customer Relations Center at 1-800-468-1502.
21 69-1 199 — 2 SMART RESPONSE ™ TECHNOLOGY Y our thermostat is actuall y a small computer . The Smart Response te chnolo gy calculates the correct time of da y to turn on y our heatin g or coolin g s y stem. Smar t Response technolo gy considers the followin g information.
69-1 199 — 22 2 WIRING DIAGRAMS THERMOSTAT 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 1 HEATING RELAY OR VALVE COIL B R RC OW Y G 2-WIRE HEAT-ONLY (JUMPER INTACT) M10616 M10617 THERMOSTAT 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
23 69-1 199 — 2 Notice: This thermo stat is a Class B di g ital apparatus that complies with Canadian Radio Interference Re g ulations, CRC c. 1374. M10619 THERMOSTAT 1 POWER SUPPLY.
Home and Building Control Home and Building Control Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1 199 — 2 J.H. Rev . 04-01 www .hone y well.com/ y ourhome Printed in U.
An important point after buying a device Honeywell CT3500/CT3595 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honeywell CT3500/CT3595 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honeywell CT3500/CT3595 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honeywell CT3500/CT3595 you will learn all the available features of the product, as well as information on its operation. The information that you get Honeywell CT3500/CT3595 will certainly help you make a decision on the purchase.
If you already are a holder of Honeywell CT3500/CT3595, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honeywell CT3500/CT3595.
However, one of the most important roles played by the user manual is to help in solving problems with Honeywell CT3500/CT3595. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honeywell CT3500/CT3595 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center