Instruction/ maintenance manual of the product WS-80 Hobart
Go to page of 10
WS-40/80 Hobart Compact Water Softener Installation Instructions WS-40 WS-80 - NOTICE - This Manual is prepared for the use of trained Hobart Service Technicians and should not be used by those not properly qualified. This manual is not intended to be all encompassing.
TABLE OF CONTENTS INSTALLATION ............................................................................................ 3 INSTALLATION WS-40/80 .............................................................................. 3 DISC REPLACEMENT .....
INSTALLATION INSTALLATION WS-40/80 SAVE THESE INSTRUCTIONS Disconnect the electrical power to the machine and follow lockout / tagout procedures. 1. Locate water supply line and appropriate drains for softener installation. 2. Install by-pass valving.
Fig. 5 9. Install one O-Ring into each groove of the brass adapter. Fig. 6 10. Apply a small amount of seal lube evenly onto each O-ring. Fig. 7 11. Remove the pin and bracket from the softener in/ out port area. Fig. 8 12. Install the brass adapters into the in/out ports and secure by reinstalling the bracket and pin.
15. Insert tubing provided into the overflow port on the back of the softener and run drain lower than the cabinet connection to provide a gravity drain in the event of a internal cabinet leak. Fig. 10 16. Review the meter disc selection chart and the water analysis provided.
Brine Valve Settings Unit Brine Setting Float Cup Height WS-40 1.0 lb. 6.25" WS-80 1.4 lb. 6.5" E. Reinstall brine valve into the cabinet. NOTE: Do not drop brine valve into drum. Dropping may lower float cup, resulting in an improper setting.
Fig. 17 27. Check for proper operation by pressing the recessed red button on bottom of salt alarm controller. If controller is operating properly - the indicator light will flash and an audible tone will be heard. Fig. 18 28. 29. Add a clean grade of salt at this time.
DISC REPLACEMENT DISC REPLACEMENT WS-40/80 1. Remove screws and cap cover from level one. Fig. 19 2. Remove balance piston. Fig. 20 3. Remove balance piston o-ring and balance piston spring. Fig. 21 4. Remove meter drive pawl. Fig. 22 5. Remove meter disc.
6. Install correct meter disc and reassemble in reverse order. NOTE: Be certain to start cap screws by hand rotating backwards until screw drops into thread then tighten. An alternating, crossing pattern should be used while tightening cap screws to ensure correct cap fit.
DISC SELECTION DISC SELECTION WS-40/80 The amount of hardness removed (in compensated gpg) will be based on the amount of brine and the meter disc selected. 1. Determine the compensated hardness. This requires a hardness test and an iron test on raw water at the application site.
An important point after buying a device Hobart WS-80 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hobart WS-80 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hobart WS-80 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hobart WS-80 you will learn all the available features of the product, as well as information on its operation. The information that you get Hobart WS-80 will certainly help you make a decision on the purchase.
If you already are a holder of Hobart WS-80, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hobart WS-80.
However, one of the most important roles played by the user manual is to help in solving problems with Hobart WS-80. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hobart WS-80 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center