© HOBART 2008 F25230 (Rev. A, May 2008) Page 1 of 8 LX/LXi, LXG/LXiG, AND SR24H DISHWASHERS DWT2 DRAIN WATER TEMPERING KIT ML-130137 All kits must be installed by a Hobart Service Technician.
F25230 (Rev. A, May 2008) © HOBART 2008 Page 2 of 8 Installation (LX/LXi and LXG/LXiG) WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove unit from wall to provide access to components. 2. Remove Base Cover from front of unit per Fig 1.
© HOBART 2008 F25230 (Rev. A, May 2008) Page 3 of 8 Plumbing Connection WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. The plumber who connects this machine is responsible for making certain the water lines are thoroughly flushed out before connecting to any manual valve or solenoid valve.
F25230 (Rev. A, May 2008) © HOBART 2008 Page 4 of 8 2. Route wiring harness per Fig 9, Fig 10, and Fig 11. Route wiring harness in a manner to ensure it is not lying on the bottom of the dishwasher per Fig 9. Make sure ground wire from harness is connected to grounding point on dishwasher per Fig 11.
© HOBART 2008 F25230 (Rev. A, May 2008) Page 5 of 8 4. Replace existing service cover with one supplied in kit (919277). The power cord will have to be disconnected from the contactor in the control drawer to replace the existing service cover. Assemble the electrical conduit connector to the service cover per Fig 14.
F25230 (Rev. A, May 2008) © HOBART 2008 Page 6 of 8 Operation 1. Make sure cold water supply line valve is open and pressure gage is set to 15 psi flowing, for a drain pump machine or 20 psi flowing for a drain solenoid machine. 2. Check for and correct any plumbing leaks.
© HOBART 2008 F25230 (Rev. A, May 2008) Page 7 of 8 5. Connect the other two wires marked as Drain1 and Drain2 in harness 814267 to drain solenoid valve as shown in Fig. 6. 6. Route the wire harness to the rear of the machine along the left side wall.
F25230 (Rev. A, May 2008) © HOBART 2008 Page 8 of 8 12. Slide strain relief bracket into the panel per Fig. 11. 13. Attach the strain relief bracket to dishwasher with a #10 screw per Fig. 12. 14. Make DWT2 cold water valve harness (919862) connections with wiring harness (814267) per Fig.
An important point after buying a device Hobart LX/LXI (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hobart LX/LXI yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hobart LX/LXI - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hobart LX/LXI you will learn all the available features of the product, as well as information on its operation. The information that you get Hobart LX/LXI will certainly help you make a decision on the purchase.
If you already are a holder of Hobart LX/LXI, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hobart LX/LXI.
However, one of the most important roles played by the user manual is to help in solving problems with Hobart LX/LXI. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hobart LX/LXI along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center