Instruction/ maintenance manual of the product KP-FD30 Hitachi
Go to page of 20
15-Jul y -200 4 1 KP-FD30 remote control protocol (Rev .1) 1) Comms* s pecificati ons Sync system S tart-stop sync Bit rate 9600 bps Data length 8 bits S tart bit 1 S top bits 1 Parity None Bit transf er LSB first *Comms : Communications 2) Comms control The remote control software controls all communications.
15-Jul y - 2004 2 a) T ransmission f rom master (norm al proc ess) Master Slave ENQ code (05H) 1) ACK code (06H) Transmit code (ASCII code) 2) 3) 4) ACK code (06H) 1) Session starts w hen ENQ is sent from master to slave. 2) Slave acknowledges by returning ACK to master .
15-Jul y - 2004 3 b) Master reads data ( normal pr ocess) Master Slave ENQ code (05H) 1) ACK code (06H) Read command (ASCII code) ACK code (06H) 2) 3) 4) Read data (ASCII code) ACK code (06H) 5) 6) 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 4 c) Data transmitted by master (control abort pro cess) Master Slave ENQ code (05H) 1) NAK code (15H) 2) 3) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) ENQ code (05H) NAK code (15H) 1) Master sends ENQ code to slave. 2) Since ACK code cannot be sent, slave sent NAK code to maste r .
15-Jul y - 2004 5 d) Data transmitted by master (data error proc ess) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (error occurs) ACK code (06H) Send data (error occurs) Send data (data normal) 4) 3 seconds elaps e 3 seconds elapse 5) 6) 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 6 e) Data f ram e error ( Master trans mission) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Send data (ASCII code) 4) 3 seconds elaps e 3 seconds elaps e 5) 6) Send data (ASCII code) Send data (ASCII code) Send data (ASCII code) 3 seconds elaps e 1) Session starts w hen ENQ is sent from master to slave.
15-Jul y - 2004 7 f) T ransmission f r ame er ror (M aster receiv e) Master Slave ENQ code (05H) 1) ACK code (06H) 2) 3) Read command (ASCII code) 4) 3 seconds elapse 5) 6) ACK code (06H) Read command.
15-Jul y - 2004 8 (4) Comm s command T ext d ata format a) Send data and r ea d command dat a (master to slave) 1) Command data are converted into ASCII code and t ransmitted. 2) Com ms byte quanti ty is 18. 3) Comms data format (transmission seq uence).
15-Jul y - 2004 9 b) Read (receive) dat a ( slave to master) 1) Command data are converted into ASCII code and t ransmitted. 2) Com ms byte quanti ty is 10. 3) Comms data format (transmission seq uence) STX Text data ETX SUM 10 bytes ■ Comm s data descript ion ・ STX : Code indicating start of text.
15-Jul y - 2004 1 KP-FD30 remote control command table (Rev.1) 1) Standard command a) Write comm and (Set da ta) TEXT data Item STX Status ID Area R.No Data ETX SUM AVE (*) 02 01 FF 01 3A 00 00 00 03 18 AREA 02 01 FF 01 3A 01 00 00 03 17 Auto Light C ontrol M ode (ALC) PEAK/AVE 02 01 FF 01 3A 00 00 00 03 16 NO.
15-Jul y -200 4 2 TEXT data Item STX Status ID Area R.No Data ETX SUM OFF (*) 02 01 FF 01 17 00 00 00 03 24 PRESET 02 01 FF 01 17 01 00 00 03 23 VARIABL 02 01 FF 01 17 02 00 00 03 22 AES 02 01 FF 01 17 03 00 00 03 21 Shutter Mode (SHU TTE R) EXT T IG 02 01 FF 01 17 04 00 00 03 20 8.
15-Jul y - 2004 3 TEXT data Item STX Status ID Area R.No Data ETX SUM 1/20000 s 02 01 FF 01 08 22 00 00 03 20 1/30000 s 02 01 FF 01 08 23 00 00 03 1F 1/50000 s 02 01 FF 01 08 24 00 00 03 1E 1/60 s(Min.
15-Jul y -200 4 4 TEXT data Item STX Status ID Area R.No Data ETX SUM A W C(PRESET) restart 02 00 FF 01 07 00 00 00 03 26 Min 02 01 FF 01 36 00 00 00 03 23 | 02 01 FF 01 36 ** 00 00 03 ** Mid (*) 02 0.
15-Jul y -200 4 5 TEXT data Item STX Status ID Area R.No Data ETX SUM OFF ( γ =1.0 ) 02 01 FF 01 14 00 00 00 03 27 GAMMA ON ( γ =0.45) (*) 02 01 FF 01 14 01 00 00 03 26 POSITIVE (*) 02 01 FF 01 01 0.
15-Jul y -200 4 6 Charcter C ode 0 ( 3 0 ) A ( 4 1 ) K ( 4 B ) U ( 5 5 ) ! ( 2 1 ) ~ ( 7 D ) 1 ( 3 1 ) B ( 4 2 ) L ( 4 C ) V ( 5 6 ) ? ( 3 F ) * ( 2 A ) 2 (32) C (43) M (4D) W (57) # (A2) % (25) 3 ( 3.
15-Jul y -200 4 7 b) Read Command (Read data) TEXT data Item STX Status ID Area R.No Data ETX SUM Auto Light C ontrol M ode (ALC) 02 01 FF 81 3A 00 00 00 03 10 Area of Light m easurement (ALC : AREA) .
15-Jul y -200 4 8 TEXT data Item STX Status ID Area R.No Data ETX SUM 1 st & 2 nd charac ters 02 01 FF 81 1E 00 00 00 03 0E 3 rd & 4 th chara cters 02 01 FF 81 1F 00 00 00 03 0D 5 th & 6 t.
15-Jul y -200 4 9 2) Special command (Fo r adjustmen t of a facto ry) Caution ! ! ▪ The item indicate d by the special c omm and is adjusted to the optim al value at the tim e of fac tory shipm ents. Please p erform after reading t he data se t up now b y the lead com mand an d mem orizing a set ting val ue, when c hanging th is item .
15-Jul y -200 4 10 TEXT data Item STX Status ID Area R.No Data ETX SUM Min 02 00 FF 02 9D 00 00 00 03 0F | 02 00 FF 02 9D ** ** 00 03 ** C-Y M atri x (Gb- y,r-g[+]) [0000-01FF] Max 02 00 FF 02 9D FF 0.
15-Jul y -200 4 11 b) Read Command (Read data) TEXT data Item STX Status ID Area R.No Data ETX SUM Standard sens itivity adjustm ent (Standard Gain) 02 01 FF 81 2E 00 00 00 03 0D ALC Level Ref . 02 01 FF 81 19 00 00 00 03 1A Peak data Ref. 02 01 FF 81 3F 00 00 00 03 0B Auto Iris Ref.
An important point after buying a device Hitachi KP-FD30 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hitachi KP-FD30 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hitachi KP-FD30 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hitachi KP-FD30 you will learn all the available features of the product, as well as information on its operation. The information that you get Hitachi KP-FD30 will certainly help you make a decision on the purchase.
If you already are a holder of Hitachi KP-FD30, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hitachi KP-FD30.
However, one of the most important roles played by the user manual is to help in solving problems with Hitachi KP-FD30. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hitachi KP-FD30 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center