Instruction/ maintenance manual of the product HHC-998 Henny Penny
Go to page of 28
OPERA T OR’S MANUAL Henny Penny Humidified Holding Cabinet s Model HHC-990 Model HHC-992 Model HHC-993 Model HHC-996 Model HHC-997 Model HHC-998.
Model HHC-990 LIMITED W ARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the original purchaser only for Henny .
Model HHC-990 T ABLE OF CONTENTS Section Page Section 1. INTRODUCTION 1-1. Humidified Holding Cabinet .................................................................................. 1- 1 1-2. Features ...............................................
Model HHC-990 1-1. HUMIDIFIED HOLDING The Henny Penny humidified holding cabinets are designed CABINET to keep hot foods moist, while maintaining proper tempera- ture. The units are electronically controlled for easy use and for consistent operation. 1-2.
Model HHC-990 1-5. SAFETY The Henny Penny Humidified Holding Cabinet has safety features incorporated. However , to ensure a safe operation, read and fully understand the proper installation, operation, and maintenance procedures. The instructions in this manual have been prepared to aid you in learning the proper proce- dures.
Model HHC-990 2-1. INTRODUCTION Installation of this unit should be performed only by a qualified service technician. Do not puncture the skin of the unit with drills or screws, or component damage or electrical shock could result.
Model HHC-990 2-2. UNP ACKING (Continued) 4 . Open doors and remove packing from behind racks and the water pan in the bottom of the unit. 5 . Peel off any protective covering from the exterior of the cabinet. 6 . The cabinet is now ready for location and use.
Model HHC-990 2-4. ELECTRICAL CONNECTION T o avoid electrical shock, the cabinet must be adequately and safely grounded (earthed) according to local electrical codes, and this appliance must be equipped with an exter - nal circuit breaker which will disconnect all ungrounded (unearthed) conductors.
Model HHC-990 2-5. CABINET DIMENSIONS AND WEIGHTS 72-1/4” (1835 mm) 31-3/4” 24-3/4” (806 mm) (628 mm) HHC-990 Unit Height Width Depth Shipping W eight HHC-993 38” (965 mm) 24-3/4” (628 mm) 3.
Model HHC-990 2-6. PROBE CLIP (OPTIONAL) The probe clip is an accessory , that may be ordered as an option, to hold the food probe when not in use. Remove one of the module screws and mount the probe clip with that screw . See photo at left. The food probe is accessed easier if the clip is mounted on the side of the unit that the door opens.
Model HHC-990 3-1. INTRODUCTION This section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Operation Sections before operating the unit. 3-2. OPERA TING CONTROLS Fig.
Model HHC-990 3-2. OPERA TING CONTROLS (Continued) 3 - 1 8 Used to access the Program Modes; once in the Program Mode, it is used to advance to the next parameter; pressing this along with accesses th.
Model HHC-990 1 2 3 4 5 6 7 8 9 10 Figure 3-1 Control Decal 3-3 303 3-2. OPERA TING CONTROLS (Continued).
Model HHC-990 3-3. ST AR T -UP Before using the humidified holding cabinet, thoroughly clean the unit as described in the Cleaning Procedures Section of this manual. 1 . Plug unit into electrical receptacle, or turn on wall circuit breaker . W ith the POWER switch turned to OFF the display shows “POWER OFF .
Model HHC-990 3-3. ST AR T -UP (Continued) 5 . Press the TEMPERA TURE button to set the desired cabinet temperature. While the LED is flashing, press the UP and DOWN buttons until the desired tempera- ture shows in the display . 6 . Press the HUMIDITY button to set the desired cabinet humidity (OFF to 90%).
Model HHC-990 3-5. CLEANING Daily: PROCEDURES 1 . T urn all controls off and disconnect electrical supply . T o avoid burns, allow the unit to cool before cleaning. 2 . Open doors and remove all trays and racks from unit, and take them to a sink to thoroughly clean.
Model HHC-990 3-5. CLEANING W eekly: PROCEDURES (Continued) 1 . Remove pans and racks from cabinet. 2 . Open drain valve and empty water pan into a shallow pan or floor drain. See Figure 3-4. Hot water! Do not place your hand under the drain while draining the unit.
Model HHC-990 This section explains the following programming functions. • Timer programming • Clock-set • Special programming 4-1. TIMER PROGRAMMING T o enter the Program Mode: 1. Press and hold for 2 seconds, and “PROG TMRS” shows in display .
Model HHC-990 4-2. CLOCK SET 6. Press and “CS-2, SET , MINUTE” shows in the (Continued) display , with the minutes flashing. 7. Press to change the minutes. 8. Press and “CS-3, SET , MONTH” shows in the display , along with the date (month flashing).
Model HHC-990 4-3. SPECIAL PROGRAMMING This mode allows you to program the following: SP-1 • Fahrenheit/celsius SP-2 • Lock/unlock SP-3 • Air temperature setpoint SP-4 • Humidity setpoint SP-5.
Model HHC-990 4-3. SPECIAL PROGRAMMING (Continued) SP-4 Humidity Setpoint 10 . Press and “SP-4, HUMIDITY SETPOINT ,” and the preset humidity setpoint shows in display . 1 1 . Press to change the humidity setpoint, 0 to 90%. SP-5 Proof Air T emperature 12 .
Model HHC-990 4-3. SPECIAL PROGRAMMING (Continued) SP-9 System Initialization 20 . Press and “SP-9, DO SYSTEM INIT” shows in display . (Factory Settings) 21 . Press and hold until the display counts down from 3, and the display flashes “-INIT -,” then “INIT*DONE”.
Model HHC-990 SECTION 5. TROUBLESHOOTING 5-1. TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Product not • Doors left open • Keep doors closed except holding temperature t o load and serve product.
Model HHC-990 303 4-7 5-2. ERROR CODES AND The display shows the following error codes and warnings when a W ARNINGS fault is detected, along with an alarm sound.
Model HHC-990 “ E-6B AIR TEMP SENSOR • Faulty air temperature F AILED SHOR TED” probe “E-12A W A TER HEA TER • Faulty water SENSOR F AILED heater probe OPEN” “E-12B W A TER HEA TER • F.
Model HHC-990 5-2. ERROR CODES AND W ARNINGS (Continued) “E-41 SYSTEM DA T A LOST” • Memory scrambled “E-46 DA T A SA VE F AILED” • Memory scrambled “E-80 VENT STUCK OR • V ent on rear.
Model HHC-990 G L O S S A R Y HENNY PENNY HOLDING CABINETS air temperature probe a round device located inside the cabinet that measures the inside air temperature and sends that information to the co.
Model HHC-990 probe clip a metal holder that attaches to the outside of the control panel to hold the food probe when not in use; the clip is an optional accessory product load capacity the highest re.
An important point after buying a device Henny Penny HHC-998 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Henny Penny HHC-998 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Henny Penny HHC-998 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Henny Penny HHC-998 you will learn all the available features of the product, as well as information on its operation. The information that you get Henny Penny HHC-998 will certainly help you make a decision on the purchase.
If you already are a holder of Henny Penny HHC-998, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Henny Penny HHC-998.
However, one of the most important roles played by the user manual is to help in solving problems with Henny Penny HHC-998. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Henny Penny HHC-998 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center