Instruction/ maintenance manual of the product RAH-183G Heat Controller
Go to page of 20
Heat Controller , Inc. • 1900 Wellworth A ve. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com O WNER’S MANU AL Room Air Heat Pump with R-410A: RAH-183G.
.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 1 C om f o r t Z on e TM Ro om Ai r Con di ti one r & Hea t Pu mp Us e an d Ca re M anu al I nt ro d u ct io n Room air conditioners cool, dehumidify, and filter air inside your home.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 2 2 To avoid death, personal injury or property damage due to electrical shock: • Observ e all loca l codes and ordi nances. • Di sconnect electr i ca l pow er to unit b efore servi cing .
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 3 3 NEMA No. 5-15P NEMA No. 5-15R 125V-1 5AMP 115V NEM A No. 6-1 5P NEMA No. 6-15 R 250V-15 AMP 2 30/2 08V rated at 12 amperes or less NEM A No. 6-2 0P NEMA No. 6-20 R 250V-20 AMP 2 30/2 08V rated over 12 amperes, but not more than 16 amperes NEMA No.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 4 4 Front Grille and Filter Removal The front contains a removable grille that provides easy access to the air filter. To clean the filter use one of the following methods for filter removal: MET HOD ONE Grasp filter handle and slide filter out of unit.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 5 5 from outer case. Use both hands to grasp basepan and pull remaining chassis from outer case. PLAS TIC FRO NT CH ASS IS BA SEP AN CLIP NOTE: Basepan clip is shipped in plastic bag with mounting screw and condensate drain cup.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 6 6 BEFORE YOU BEGIN Re a d t h e s e i n s t r u c t i o n s c o m p l e t e l y and carefully.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 7 Type A (6) V-support (2) Wi n d o w l o c k i n g b r a c k e t ( 2 ) Top mounting rail Ri g h t accordion panel Foam top wind.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 8 Installation Instructions WINDOW REQUIREMENTS ● T h es e i n s tr u cti on s a r e f o r a s ta n da r d do u b le -h u ng w i nd o w. You w i ll n e ed to m o di fy the m f or o th er ty p e s o f w in do w s .
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 9 PREPARE THE CASE In s ta ll the to p m o u n t i ng r a i l w ith 4 ty pe B s cr e w s fr o m the in s id e of the c a s e . Insert the frames for the accordion panels into the top mounting rail and the bottom frame guides.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 1 0 I n s t a l l a t i o n I n s t r u c t i o n s INSTALL THE CASE IN THE WINDOW (cont.) A dju s t the le v e lin g bo lts a nd n u t s a g a in s t t he o uts i de w a ll s o tha t the ca s e h a s a s li gh t tilt t o the outs ide.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 11 11 INS TALL THE AIR CONDITIONER IN THE CASE Slide the a i r co n di t i o ne r in to the ca s e . D o n o t pu s h on th e co n tro ls o r the fin n ed c o ils . Make s u r e t he a ir c o nd itio ne r is fi r m l y s ea ted .
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 12 C on t r ol s Mo de Pad Use to set the air conditioner to Cool , Energy Saver , Fan Only Heat (on some models) mo de . or co nt rol pa nel in dic at e t he se lec te d se tt ing s.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 13 T o e ns ur e p rop er op era ti on , a im th e r emo te co nt ro l a t t he si gna l r ec eiv er on th e a ir co nd it io ne r . T he re mo te c on tr ol si gn al has a r an ge of up to 20 fe et .
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 1 4 Fan Control OFF – Completely shuts off the unit. To prevent blowing fuses, wait two minutes after turning the unit off before turning it on again. LOW COOL – Filters and circulates room air with the fan running continuously on low speed.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 15 1 7 Be fo re Ca lli ng S erv ic e To redu c e the ris k of electric sh ock, perso n al i njury , o r d eath, turn the f an control to t he off posit io n and r emove th e unit p lug f rom the w all outlet b efore doing any in spection or mainten an ce work.
Owner ’s Manual Room Air Heat Pump with R-410A Heat Controller , Inc. 1 6 THIS P AGE W AS LEFT INTENTIONALL Y BLANK.
Heat Controller , Inc. Room Air Heat Pump with R-410A Owner ’s Manual 1 7 THIS P AGE W AS LEFT INTENTIONALL Y BLANK.
04/2009 0 7 /2010 66129905195.
An important point after buying a device Heat Controller RAH-183G (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Heat Controller RAH-183G yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Heat Controller RAH-183G - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Heat Controller RAH-183G you will learn all the available features of the product, as well as information on its operation. The information that you get Heat Controller RAH-183G will certainly help you make a decision on the purchase.
If you already are a holder of Heat Controller RAH-183G, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Heat Controller RAH-183G.
However, one of the most important roles played by the user manual is to help in solving problems with Heat Controller RAH-183G. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Heat Controller RAH-183G along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center