Instruction/ maintenance manual of the product DMC24DB-1 Heat Controller
Go to page of 70
Wall Mounted Multi-Split System Air Conditioning/Heat Pump DMC24DB-1 DMH24DB-1 Befor e servicing the unit, r ead the “safety pr ecautions” in this manual.
2 Multi type Air Conditioner Multi type Air Conditioner Ser vice Manual T ABLE OF CONTENTS Combination table ....................................................................................................................................... 3 Safety Precautions .
Ser vice Manual 3 Operation 1 Unit 2 Unit Combination of Indoor Unit(kBtu/h) Cooling Each Capacity Unit-A Unit-B UNIT-A(Btu/h) UNIT-B(Btu/h) Total Btu/h kW UNIT-A(Btu/h) UNIT-B(Btu/h) Btu/h kW Total C.
4 Multi type Air Conditioner Saf ety Precautions Safety Precautions T o pre v ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
Ser vice Manual 5 Saf ety Precautions Do not install, remove, or re- install the unit by y ourself (customer). • There is risk of fire, electric shock, explosion, or injury. Be cautious when unpacking and installing the product. • Sharp edges could cause injury.
6 Multi type Air Conditioner Saf ety Precautions Do not open the inlet grill of the product during operation. (Do not touch the elec- trostatic filter , if the unit is so equipped.) • There is risk of physical injury, electric shock, or product failure.
Ser vice Manual 7 Saf ety Precautions When the product is not to be used f or a long time , disconnect the power b y turning off the breaker . • There is risk of product damage or failure, or unintend- ed operation. T ake care to ensure that nobody could step on or fall onto the outdoor unit.
8 Multi type Air Conditioner Saf ety Precautions Do not expose the skin direct- ly to cool air f or long periods of time. (Don't sit in the draft.) • This could harm to your health. Do not use the product f or special purposes, such as preserving foods, w orks of ar t, etc.
Ser vice Manual 9 Saf ety Precautions Do not rechar ge or disassemble the batteries. Do not dispose of batteries in a fire. • They may burn or explode. If the liquid from the batteries gets onto y our skin or clothes, wash it well with c lean water .
10 Multi type Air Conditioner Dimensions Dimensions Indoor Unit Split T ype Indoor Installation plate D H W W mm(in) 895(35.2) H mm(in) 282(11.1) D mm(in) 165(6.
Ser vice Manual 11 Outdoor Unit W D L1 L2 L4 L3 H L7 L5 L6 W mm(in) 870(34.3) H mm(in) 800(31.5) D mm(in) 320(12.6) L1 mm(in) 370(14.6) L2 mm(in) 25(1.
12 Multi type Air Conditioner Product Specifications Pr oduct Specifications DMC24DB-1 23,600/24,000 11,800/12,000 208/230V -- 2.4(0.085) 1.2(0.042) at 230V 1Ø, 208/230V, 60Hz Indoor – 9.4(331.9) Outdoor 53(1871.8) Indoor – 36/32/29 at 230V Outdoor 54 2,390/2,390 1,420/1,420 -- 10.
Ser vice Manual 13 Product Specifications DMH24DB-1 23,600/24,000 11,800/12,000 208/230V 23,600/24,000 11,800/12,000 2.4(0.085) 1.2(0.042) at 230V 1Ø, 208/230V, 60Hz Indoor – 9.4(331.9) Outdoor 53 Indoor – 36/32/29 at 230V Outdoor 54 2,390/2,390 1,420/1,420 2,440/2,440 1,620/1,620 10.
14 Multi type Air Conditioner Installation Installation Type "A" screw and plastic anchor Type "B" screw Remote Control Holder Installation plate Figure Figure Name Screw driver El.
Ser vice Manual 15 Installation Indoor unit 1. Do not hav e any heat or steam near the unit. 2. Select a place where there are no obstacles in front of the unit. 3. Make sure that condensation dr ainage can be conv e- niently routed aw a y . 4. Do not install near a doorwa y .
16 Multi type Air Conditioner Installation Multi Piping T ype Piping length and elev ation 24k 30m(100ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft) Capacity(Btu/h) Max total length of all pipes (A+B) M.
Ser vice Manual 17 Installation The wall you select should be strong and solid enough to prevent vibration 1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using a level.
18 Multi type Air Conditioner Flaring Work and Connection of Piping Flaring w ork Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure. Cut the pipes and the cable. 1. Use the piping kit accessory or the pipes purchased locally.
Ser vice Manual 19 Flaring Work and Connection of Piping Check 1. Compare the flared work with the figure by. 2. If a flared section is defective, cut it off and do flaring work again. Indoor 1. Prepare the indoor unit's piping and drain hose for installation through the wall.
20 Multi type Air Conditioner Flaring Work and Connection of Piping 4. Indoor unit installation Hook the indoor unit onto the upper portion of the installa- tion plate.(Engage the two hooks of the rear top of the indoor unit with the upper edge of the installation plate.
Ser vice Manual 21 Flaring Work and Connection of Piping 1. Route the indoor tubing and the drain hose to the required piping hole position. 2. Insert the piping, drain hose, and the connecting cable into the piping hole. 3. Insert the connecting cable into the indoor unit.
22 Multi type Air Conditioner Wrap the insulation material around the connecting por- tion. 1. Overlap the connection pipe heat insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there may be no gap.
Ser vice Manual 23 Flaring Work and Connection of Piping Remove the battery cover from the remote con- troller. • Slide the cover according to the arrow direction. Insert the two batteries. • Be sure that the (+) and (-) directions are correct. • Be sure that both batteries are new.
24 Multi type Air Conditioner Outdoor Align the center of the pipings and sufficiently tighten the flare nut by hand. Finally, tighten the flare nut with torque wrench until the wrench clicks. • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.
Ser vice Manual 25 Flaring Work and Connection of Piping Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
26 Multi type Air Conditioner Connect the cable to the Outdoor unit. 1. Remove the cover control from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as the following. 2. Secure the cable onto the control board with the holder (clamper).
Ser vice Manual 27 Connecting the Cable betw een Indoor Unit and Outdoor Unit (1) Remove two-caps on the conduit panel. (2) Make a hole appropriate for the passage of connection cable through on cap by tool. (for low voltage line) (3) Pass the connecting cable through the hole.
28 Multi type Air Conditioner Connect the cable to the indoor unit CA UTION: Pro vide a cir cuit breaker between power sour ce and the unit as shown below . Air Conditioner Circuit Breaker Use a circuit breaker or time delay fuse . Main power source Model 24k 1 Ø , 230/208V P er max.
Ser vice Manual 29 Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Chec king the drainage T o check the draina ge . 1. Pour a glass of water on the evaporator. 2. Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.
30 Multi type Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting Forming the piping Form the piping by wrapping the con- necting portion of the indoor unit with insulation material and secure it with two kinds of vin yl tape .
Ser vice Manual 31 Air Purging and Ev acuation Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. 1. Pressure in the system rises. 2. Operating current rises. 3. Cooling(or heating) efficiency drops. 4. Moisture in the refrigerant circuit may freeze and block capillary tubing.
32 Multi type Air Conditioner Checking the Dr ainage, F or ming the Pipings and Long Pipe Setting 1. Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valve is open.
Ser vice Manual 33 Charging ■ Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set for each indoor line. Any time total line set is used either shorter or longer then the nominal 22.5m(75ft: for tri-zone) line set length the refrigerant charge has to be adjusted.
34 Multi type Air Conditioner 1. Check that all tubing and wiring have been properly con- nected. 2. Check that the gas and liquid side service valves are fully open. 1) Prepare remote controller Remove the battery cover by pulling it according to the arrow direction.
Ser vice Manual 35 Operation 1. MAIN UNIT FUNCTION • DISPLA Y Operation Indicator • On while in appliance operation, off while in appliance pause • Flashing while in disconnection or short in Thermistor (3 sec off / 0.
36 Multi type Air Conditioner Operation 27°C(80.6 °F) , it operates with Super-Low(while in sleep mode, with the medium airflow speed). • While compressor off, the indoor fan is off when the indoor pipe temp is below 33°C(91.4 °F) , when above 35°C(95 °F) , it operates with the low airflow speed.
Ser vice Manual 37 Operation 2) Fuzzy Operation for Dehumidification • According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5 ° C(0.9 ° F) or more below the setting temp, the compressor is turned off. When 0.5 ° C(0.
38 Multi type Air Conditioner Operation • If the appliance is on pause at the time set by the timer, the pause continues. ■ Off-Timer <=> On-Timer Operation • When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is carried out according to the set time.
Ser vice Manual 39 Operation ■ Forced Operation • To operate the appliance by force in case that the remote control is lost, the forced operation selection switch is on the main unit of the appliance to operate the appliance in the standard conditions.
40 Multi type Air Conditioner "Wall Mounted Type is standard" * Functions is dependent on model type. Operation Function of Indoor Unit On/Off : Lights up during the system operation. Sleep Mode : Lights up during Sleep Mode Auto operation. Timer : Lights up during Timer operation.
Ser vice Manual 41 Operation Function of Outdoor Unit Outdoor Unit Operating Step LEV Control Out door Fan Control • Compressor step varies considering condition such as room temp,outdoor temp, operating room number,Temp gap between room temp and set temp and so on.
42 Multi type Air Conditioner Operation Remote Contr ol Operation ON OFF CANCEL AUT O CLEAN ° C/ ° F SET Cooling Operation Auto Operation Healthy Dehumidification Operation Flip-up door (opened) Hea.
Ser vice Manual 43 Disassembly Disassembl y Indoor Unit Split T ype Indoor Unit Disconnect the unit from power supply before mak- ing any checks. Be sure the power switch is set to “OFF”. To remove the Grille from the Chassis. • Set the up-and-down air discharge louver to open position (horizontally) by finger pressure.
44 Multi type Air Conditioner Disassembly 2. T o remove the Contr ol Bo x. • Remove securing screws. • Pull the control box out from the chassis carefully. 3. T o remove the Dischar ge Grille . • Unhook the discharge grille and pull the discharge grille out from the chassis carefully.
Ser vice Manual 45 Disassembly • Unhook the tab on the right inside of the chassis at the same time, slightly pull the evaporator toward you until the tab is clear of the slot. 5. T o remove the Motor Co ver • Remove 2 securing screw. • Pull the motor cover out from the chassis carefully.
46 Multi type Air Conditioner Schematic Diagram Schematic Dia gram Electr onic Contr ol Device 1. Indoor Unit 1) Split T ype.
Ser vice Manual 47 Schematic Diagram 2. Outdoor Unit P07 SW01F OR2H,OR7H,OR10H:91K,OR3H-4H,OR8H-9H,OR11H-12H:15K(ETC:20K) R03T 1 1 DC 5V 56K R04T 1K 1 2 7036P IC01A CN-JIG 3 4 3 4 2 2 JIG_RX JIG_TX DC 5V 10K R01T 1K R02T C01H-C04H : 103 P21 21 JIG_RX 26 OSC01B CST-8.
48 Multi type Air Conditioner Schematic Diagram 23.2K 8.06K 8.06K 23.2K 23.2K 8.06K 1% 1% 51.1K 102 100V C25M 1% 9.1k R27M 100uf C24M + 2 5 4 6 100uF 25V C26M R28M 13K 1% 1 5 + R29M,2K,1% 4 22 51.1K 10K 1 2.94K 6 7 4.7K PWM(C) 35.7K 4.3K R26M 10.2K 3 2 1 21.
Ser vice Manual 49 1. Room T ype Indoor Unit Wiring Diagram Schematic Diagram 2. Outdoor Unit 1) DMH24DB-1 2) DMC24DB-1.
50 Multi type Air Conditioner Schematic Diagram 1. Indoor Unit MAIN P .C.B ASM 1) Split T ype Components Locations • T OP VIEW • BO TT OM VIEW PCB :6870A90409B ASSY :6871A20771 6871A20782.
Ser vice Manual 51 Schematic Diagram 2. Display ASSEMBL Y 1) Split T ype (6871A20680).
52 Multi type Air Conditioner Schematic Diagram 3. Outdoor Unit 1) Component side.
Ser vice Manual 53 Schematic Diagram 2) Solder side.
54 Multi type Air Conditioner High Pres. S witch Cons. Comp (GK094K) C/V1 C/V2 Th1 Th2 Acc. A-Room B-Room LEV-A LEV-B Air Sensor Eva. Sensor Eva. Sensor 9.52 6.35 LEV 15RC R/Valve 5220AR3228E Air Sensor strainer strainer Sensor Cons. Comp (GK141K) Ø Ø 1.
Ser vice Manual 55 T roubleshooting Guide ■ Error Indicator • The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble. • Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.
56 Multi type Air Conditioner T roubleshooting Guide T r ouble anal ysis 1. Check temperature difference between intake and discharge air, and operating current.
Ser vice Manual 57 T roubleshooting Guide Electr onic P ar ts T r oubleshooting Guide ❇ Refer to electronic contorol device drawing & schematic diagram. The Pr oduct doesn’t operate at all. Turn off the main power and wait until LED on outdoor PCB is off.
58 Multi type Air Conditioner T roubleshooting Guide Turn on main power. While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped. When the compressor stopped Indoor Fan is driven by a low speed.
Ser vice Manual 59 T roubleshooting Guide Turn on the main power. When in air circulation mode, compressor/outdoor fan is stopped. Turn off main power. Check the electrical wiring diagram of Outdoor side. Check the open or short of connecting wires between Indoor and Outdoor.
60 Multi type Air Conditioner T roubleshooting Guide When indoor F an does not operate . Check connecting condition of the CN-MOTOR CON- NECTOR Does the voltage of terminal of CN-DC/DC CONNECTOR in In.
Ser vice Manual 61 T roubleshooting Guide When the louver does not operate . T r ouble 5 When V er tical Louver does not operate. • Confirm that the Vertical Louver is normally geared with the shaft of Stepping Motor.
62 Multi type Air Conditioner T roubleshooting Guide Err or Code ■ Trouble Shooting Error Title Cause of error Check point & Normal condition code 01 Indoor air sensor 02 Indoor inlet pipe senso.
Ser vice Manual 63 T roubleshooting Guide Error Title Cause of error Check point & Normal condition code 05 / 53 Communication (Indoor ➔ Outdoor) • Communication poorly • Power input AC 230V.(Outdoor, Indoor) • The connector for transmission is disconnected.
64 Multi type Air Conditioner T roubleshooting Guide Error Title Cause of error Check point & Normal condition code 33 D-Pipe Temp. High • Discharge sensor temp. high • Check the discharge pipe sensor. • Check the install condition for over load.
Ser vice Manual 65 T roubleshooting Guide Error Title Cause of error Check point & Normal condition code 44 Outdoor air sensor 45 Condensor pipe sensor 47 D-Pipe sensor • Open / Short • Solder.
66 Multi type Air Conditioner 2-wa y , 3-wa y V alv e 2-wa y , 3-wa y V alve 2-way Valve (Liguid Side) 3-way Valve (Gas Side) Works Shaft position Shaft position Service port Shipping Closed Closed Cl.
Ser vice Manual 67 2-wa y , 3-wa y V alv e • Be sure to short pressure S/W. otherwise Low pressure S/W detect low pressure skete and stops the compressor. (1) Pumping down • Procedure 1. Confirm that both the gas side and liquid side valves are set to the open position.
68 Multi type Air Conditioner 2-wa y , 3-wa y V alv e (2) Ev acuation (All amount of refrigerant leaked) • Procedure 1. Confirm that both the liguid side valve and gas side valve are set to the opened position. 2. Connect the vaccum pump to the center hose of the manifold gauge.
Ser vice Manual 69 2-wa y , 3-wa y V alv e (3) Gas Charging (After Evacuation) • Procedure 1. Connect the gauge to the charging cylinder. - Connect the charge hose which you disconnect- ed from the vacuum pump to the valve at the bottom of the cylinder.
Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL WOR TH A VENUE • J A CKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONING AIR P/No .
An important point after buying a device Heat Controller DMC24DB-1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Heat Controller DMC24DB-1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Heat Controller DMC24DB-1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Heat Controller DMC24DB-1 you will learn all the available features of the product, as well as information on its operation. The information that you get Heat Controller DMC24DB-1 will certainly help you make a decision on the purchase.
If you already are a holder of Heat Controller DMC24DB-1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Heat Controller DMC24DB-1.
However, one of the most important roles played by the user manual is to help in solving problems with Heat Controller DMC24DB-1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Heat Controller DMC24DB-1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center