Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 1 • DO NOT store or use gasoli ne or other am- mab le vap or s an d l iqu id s in th e v ici nit y o f t his or any other appliance. • Whattodoifyousmellgas - DO NOT try to light any appliance.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 2 ListingLabelInformation/Location Model Name: ___________________________________________ Date purchased/inst.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 3 Safety AlertKey: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 4 = Contains updated information. F . Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 55 G. W all Switch Installation for Fan (Optional) .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 5 B. LimitedLifetimeW arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 6 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 7 B. T emperedGlassSpecications Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as dened by the Con- sumer Product Safety Commission (CPSC).
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 8 E. N on-C omb us tib leMa teri als Spec icat ion Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 9 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 10 Figure2.1GeneralOperatingParts B. Y ourFireplace W ARNING! DO NOT operate replace before read - ing and understanding operating instructions.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 1 1 D. ClearSpace W ARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 12 J. BeforeLightingFireplace Before operating this replace for the rst time, have a qualiedservicetechnician : • V erify all shipping materials have been removed from inside and/or underneath the rebox.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 13 K. LightingInstructions(IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 14 L. LightingInstructions(StandingPilot) 1. T urn of f all electric power to the appliance if ser- vice is to be performed. 2. Open control access panel. 3.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 15 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the replace off and allow it to completely cool. • Remove xed glass assembly .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 16 GlassCleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 17 V enting Frequency: Seasonally By: Homeowner T oolsneeded: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruc tion such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 18 Figure3.1IPIPilotFlamePatterns Figure3.2StandingPilotFlamePatterns C. Refractory ,GrateandV alve Assembly Removal It may become necessary to remove the refractory , grate and valve assemblies.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 19 Figure3.5V alveAssemblyRemoval NOTCH LOCA TION NG LP 6000C 6000CL 6000CLX 6000CBV 8000C 8000CL 8000CLX 8000CBV Figure3.6BurnerIdentication D.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 20 A. T ypical ApplianceSystem NOTICE: Illustrations and photos reect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 21 B. DesignandInstallationConsiderations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 22 5 F ramingandC learances A. Selecting ApplianceLocation Whe n sele cting a locat ion for the appli anc e it is impor tan t to con sid er the requ ire d c lea ran ces to w all s ( see Fi gure 5.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 23 B. Constructingthe ApplianceChase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 24 D. MantelandW allProjections W ARN IN G! Ri sk of Fir e! Co mp ly wi th al l mi nim um c le ar - an ces as spe ci ed.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 25 A. V entT erminationMinimumClearances RoofPitch H(Min.)Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 26 Figure6.3 MinimumClearancesforT ermination O N P R Q X = AIRSUPPL YINLET A = 12 inches.................clear ance s ab ove gra de, veranda, por ch, dec k o r b alc ony B = 12 inches.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 27 A. ApprovedPipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 28 H 1 V 1 Figure7.3 T opV ent-HorizontalT ermination T opV ent-HorizontalT ermination On.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 29 H 2 H 1 V 2 V 1 Figure7.5 T opV ent-HorizontalT ermination-(continued) ThreeElbows V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 30 EXHAUST SHIELD FLUE RESTRICTOR T opV ent-V erticalT ermination NoElbow Figure7.6 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the ue restrictor should be used.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 31 H 1 V 1 V 2 T opV ent-V erticalT ermination(continued) Figure7.1 1 T woElbows Figure7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 32 Figure7.12 T opV ent-V erticalT ermination-(continued) ThreeElbows IN STALLE D HO R IZO NTALL Y H 1 H 2 V 1 V 2 V 1 H 1 +H 2 V 2 V 1 + V 2 Minimum H 1 +H 2 Maximum Elbow only 1 ft.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 33 H 1 RearV ent-HorizontalT ermination Figure7.14 NoElbow One45ºElbow H 1 H 1 =16in.(406mm)Maximum Do not use a 45º elbow in corner installations.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 34 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 RearV ent-HorizontalT ermination-(continued) T woElbows Figure7.15 Figure7.16 ThreeElbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 +H 2 Maximum 1 ft.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 35 RearV ent-V erticalT ermination OneElbow Figure7.17 T woElbows Figure7.18 H 1 V 1 IN STALLE D HO RI ZO NTALL Y H 1 H 2 V 1 V 1 Minimum H 1 Maximum 6 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 36 RearV ent-V erticalT ermination-(continued) ThreeElbows Figure7.19 ThreeElbows Figure7.20 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 +H 2 +H 3 Maximum * * * 8 ft.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 37 EXHAUST VENT PIPE INLET AIR VENT PIPE Figure7.21.Coaxial/Colinear ApplianceConnector OUTSIDE F ACE OF FIREPLACE TOP OF FIREPLACE OPENING SHADED AREA DEFINED AS “INSIDE EXISTING MASONR Y FIREPLACE” 3 IN.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 38 Figure7.23 EXISTING CHIMNEY HEARTH FLOOR EXISTING CHIMNEY EXHAUST AIR VENT PIPE INLET AIR VENT PIPE T o minimize cold air drafts, seal with non-combustible insulation.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 39 A* B* 10 in. 12 in. C D 10 in. 12 in. A. PipeClearancestoCombustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 40 C. InstalltheCeilingFirestop A ceilin g restop MUST be used between oors and attics.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 41 D. Install AtticInsulationShield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 42 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 43 B. RearV ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 44 Figure9.14ProperPositioningandSecuringofan Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure9.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 45 1 0 Inst allingV entPi pe(D VPandSLPP ipe ) A.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 46 B. AssembleV entSections(SLP PipeOnly) T o attach the rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 47 120º Figure10.8SecuringV erticalPipeSections 120º Figure10.9SecuringHorizontalPipeSections E. Di sa ss em bl e V en t S ec ti on s • Rotate either section (see Figure 10.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 48 F . Install Decorative Ceiling Components (SLPonly) A decorative ceiling thimble can be installed on a at ceil- ing through which the vent passes.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 49 G. InstallMetalRoofFlashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 50 SCREWS CAULK STORM COLLAR (1of3) Figure10.18 TERMINA TIONCAP I.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 51 Figure10.20V entingthroughthewall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 52 A. FuelConversion • Mak e sure the applian ce is comp atib le with availab le gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies specied and approved parts.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 53 Figure12.1IgnitorButton C. StandingPilotIgnitionSystemWiring • The standin g pilot ignition system wiring does not requir e a 1 10 V AC supply to operate.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 54 Figure12.2IPIWiringDiagram TO JUNCTION BOX (1 10V) MODULE FLAME SENSE IGNITER RC100 RC200 (OPTIONAL W.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 55 G. W allSwitchInstallationforFan(Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 56 1 3 F inishing A. MantelandW allProjections W ARN IN G! Ri sk of Fi re ! Com pl y wi th a ll mi ni mu m cl ear - an ces as sp ec ie d.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 57 Figure13.4FinishingMaterial1InchThickorLess DOOR FIT FINISHMA TERIAL THICKNESS SEE FIGURE Folio Inside Any 13.6 Arcadia Overlap 1 inch or less 13.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 58 DOOR FINISHING MA TERIAL FINISHING MA TERIAL C (Includes 1/8 in. opening each side of door) A (Outside door width) Finishing material thickness, 1-4 inches maximum B = T op of door to bottom of replace.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 59 FINISHING STRIPS REMOVED Figure13.7RemovingFinishingStrips. 31-7/8 IN. (6000) 33-1 1/16 IN. (8000) 3-3/4 IN. (6000, 8000) 35-5/16 IN. (6000) 43 IN. (8000) Figure13.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 60 D. ElevatedHearthSystems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 61 A. RemoveFixedGlass Assembly See Section 14.H. B. RemovetheShippingMaterials Remove shipping materials from inside or underneath the rebox.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 62 G. InstalltheLog Assembly LogAssembly:LOGS-6C CAUTION: Logs are fragile, handle with care. Log #1(SR V2164-701) : Locate log placement tabs on the pilot cover .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 63 Figure7 2 3 1 Log #3 (SRV2164-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on top of Log #1.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 64 Models:8000C,8000C-LP ,8000C-IPI, 8000C-IPILP ,8000CBV -IPI Figure3 Figure4 GROOVES SLOTS Figure5 Figure6 1 2 1 LEFTGRA TETINE CAUTION: Logs are fragile, handle with care.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 65 Figure7 2 3 1 1 2 3 4 Figure8 Figure9 Figure10 1 1 2 2 3 3 4 5 5 6 4 Log #3 (SRV2168-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on top of Log #1.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 66 Figure14.5 AirShutter Figure14.4FixedGlass Assembly H. FixedGlass Assembly W ARNING! Risk of Asphyxiation! Handle xed glass assembly with care.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 67 A. StandingPilotIgnitionSystem 1 5 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 68 T roubleshooting(continued) Symptom PossibleCause Corrective Action 3. (Continued) C. V alve. T urn the valve knob to the ON position. Place the ON/ OFF switch in the ON position.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 69 B. IntelliFirePlus™IgnitionSystem Symptom PossibleCause Corrective Action 1. Pilot won’t light. The ignitor/module makes noise, but no spark. A.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 70 1 6 ReferenceMater ials A. ApplianceDimensionDiagram Di me ns ion s ar e a ct ua l ap pli an ce di me ns ion s. U se f or re fe ren ce o nl y . Fo r fra mi ng di me ns io ns an d cl ear an ce s re fer t o Sec ti on 5 .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 71 Figure16.2 ApplianceDimensions-8000Models Location Inches Millimeters J 21 5.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 72 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 73 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 74 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 75 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 76 OptionalWireHarness DESCRIPTION P ARTNUMBER 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 77 B. V entComponentsDiagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT ALTERMINA TIONCAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 78 B. V entComponentsDiagrams (continued) Figure16.8SLPSeriesV entComponents.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 79 B. V entComponentsDiagrams (continued) Figure16.9SLPSeriesV entComponents SLP-WT -BK W all Thimble-Black 26 in. 660 mm DVP-HSM-B Extended Heat Shield SLP-TRAP Horizontal T ermination Cap 15-1/8 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 80 13 in. 330 mm 13 in. 330 mm 1-5/16 in. 34 mm 10-9/16 in. 269 mm 14 in.
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 81 ServiceParts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 82 ServiceParts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 83 ServiceParts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 84 ServiceParts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 85 ServiceParts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI • 2164-900 Rev . T • 9/12 86 D. ContactInformation Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .
An important point after buying a device Heat & Glo LifeStyle 6000C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Heat & Glo LifeStyle 6000C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Heat & Glo LifeStyle 6000C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Heat & Glo LifeStyle 6000C you will learn all the available features of the product, as well as information on its operation. The information that you get Heat & Glo LifeStyle 6000C will certainly help you make a decision on the purchase.
If you already are a holder of Heat & Glo LifeStyle 6000C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Heat & Glo LifeStyle 6000C.
However, one of the most important roles played by the user manual is to help in solving problems with Heat & Glo LifeStyle 6000C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Heat & Glo LifeStyle 6000C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center