Installation Instructions Installation Instructions (In Toronto Area only: 1-905-3061093) Certified to comply with ASME A112.19.2M © 2008 AS America, Inc. NOTE TO INSTALLER: Please give this manual to the customer after installation. SELECTRONIC™ PROXIMITY TOILET FLUSH V AL VE 1.
Installation Instructions 5. Sweat Solder Adapter 6. Cover Tube 7. Wall Escutcheon 8. Supply Stop 9. Installation Instructions 1. Flush Valve Assembly 2. Down Tube and Vacuum Breaker 3. Spud Coupling Nut and Washers 4. Spud Flange All American Standard Products Are Water Tested At Our Factory.
Installation Instructions RECOMMENDED TOOLS; Fig. 2 Fig. 2 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Teflon Tape Flat Blade Screwdriver Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection; Solder and Torch 2.
Installation Instructions 1 1 2 3 4 5 1 4 2 3 Fig. 4 Fig. 5 1. Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension “X”). Cut COVER TUBE (1) to length (X). Apply Teflon Tape to the threaded end of the Adapter or supply pipe.
Installation Instructions 4 M968699 Rev . 1.3 1 CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP REMOVE COVER Fig. 6 1. Remove COVER (1) from SUPPLY STOP (2) . 2. With a flat blade screwdriver open SUPPLY STOP (2) . 3. Turn on water supply to flush line of any debris or sediment.
Installation Instructions M968699 Rev . 1.3 7 9 6 2 1 5 8 10 121mm,+13mm, -6mm (4-3/4)(+1/2, -1/4) Fig. 8b 5 Fig. 9 2 REMOVE COVER CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP IM.
Fig. 12b Installation Instructions M968699 Rev . 1.3 9 6 1. Remove COVER (1) from SUPPLY STOP (2) if installed. Fig. 10. 2. Turn water supply off. Fig. 10. 3. Loosen SPUD COUPLING NUT (3) . Unthread COUPLING NUT (4) and VACUUM BREAKER COUPLING NUT (5) .
Installation Instructions M968699 Rev . 1.3 7 Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below. 1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of top half of FLUSH VALVE (3) .
Installation Instructions M968699 Rev . 1.3 8 IS STOP VALVE OPEN? LOOK FOR REPEATED DOUBLE FLASH ON SENSOR YES INSTALL NEW BATTERY TRY MANUAL VALVE BUTTON; WILL THE UNIT FLUSH? NO REPLACE PISTON KIT I.
Installation Instructions M968699 Rev . 1.3 9 HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 W eekdays 8:00 a.m. to 6:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) W eekdays 8:00 a.m. to 7:00 p.
An important point after buying a device American Standard 065.525 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Standard 065.525 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Standard 065.525 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Standard 065.525 you will learn all the available features of the product, as well as information on its operation. The information that you get American Standard 065.525 will certainly help you make a decision on the purchase.
If you already are a holder of American Standard 065.525, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Standard 065.525.
However, one of the most important roles played by the user manual is to help in solving problems with American Standard 065.525. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Standard 065.525 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center