Instruction/ maintenance manual of the product SUDP8000I American Power Conversion
Go to page of 24
990-1007A , Rev ision 2 9/99 Smart-UPS DP Uninterruptible Pow er Supply Models SUDP4000I, SUDP6000I, SUDP8000I, SUDP10000I User’s Manual.
Entire con tents copyrig ht ©1999 by A meri can Pow er Conv ersion. A ll rig hts res erved. Reprodu ction i n w hole or in part with out permission is prohibited. Smart- UPS is a registered trademark of A PC. All other trademark s are the property of their respective ow ners .
990-1007A , Rev ision 2 9/99 Smart-UPS DP Quick Reference Guide English About Your New UPS This Uninterruptible Power Supply (UPS) prevents blackouts, brow nouts, s ags an d surges from reaching you r.
.
990-1007A , Rev ision 2 9/99 i Table of Contents Safety ...................................................................................................................................................................................................
990-1007A , Rev ision 2 9/99.
990-1007A , Rev ision 2 9/99 1 Safety This Sa fety G uide contains importa nt instructions tha t should be f ollowe d during insta llation and m aintenanc e of the APC equipm ent and ba tteries . It is intended f or APC customer s who setup, install, re locate, or m aintain A PC equipment.
990-1007A , Rev ision 2 9/99 2 Initial Insp ection Inspection Inspect the UPS upon receipt. Notif y th e carrier and dealer if th ere is damag e. The packaging is recyclable; sav e it for reuse or dis pose of i t properly . Unpacking Move the UPS, in its s hipping pack age, as close to th e desired location as poss ible.
990-1007A , Rev ision 2 9/99 3 Placement Sm a r t - U P S D P Sm a r t - U P S D P Sm a r t - U P S D P Install the UPS in a protected area th at is free of ex cessive dust an d has adequate air f low .
990-1007A , Rev ision 2 9/99 4 Externa l Connections Notes: As a standar d, the S mart-UPS DP is made for sing le-phase connecti on. Due to the leakage current of 3 .5 t o 10 mA, the Smart-UPS DP mu st alw ay s be grounded according to local reg ulations.
990-1007A , Rev ision 2 9/99 5 Rear Views F 0 0 1 M a i n s F 0 0 1 M a i n s 16) 15) 14) 13) 12) 11) 10) 9) 8) 7) 6) 5) 4) 3) 2) 1) A DC AH MIN. : STO RED E NERG Y TIME OU TPUT : INPUT : AH V DC / V / 2. REPLACEMENT 1. REPLACEMENT INSTA LLE D YEAR MONTH REPLACEMENT OF B AT TE RI E S KG.
990-1007A , Rev ision 2 9/99 6 Common Fault The function of the com mon fault relay is factory preset. For ch anging the factory setting, please contact y o ur local dealer. Principa l Diagram (common fault) 1 NC 2 NO 3 Com 4 Com Data: Relay contacts - ohmi c load DC m in.
990-1007A , Rev ision 2 9/99 7 14 NC1 15 NC1 NO1 2 COM1 NO1 COM1 CHGND X005 EPO RELAY CONNECTOR 16 NC2 17 NC2 NO2 4 COM2 NO2 COM2 CHGND 18 NC3 19 NC3 NO3 6 COM3 NO3 COM3 CHGND 20 NC4 21 NC4 NO4 8 COM4.
990-1007A , Rev ision 2 9/99 8 Optional Equipment I nst allation Galvanic Isolation T ransformer The galvanic is olation transf ormer can be delivered for one- or two- phase conn ection. When con necting a Sm art-UPS DP and galvanic isolation transf ormer, the A C bus and the w ires for the thermo sw itch m ust be mounted.
990-1007A , Rev ision 2 9/99 9 Standard S ystem With Is olating Trans form er (400 V) System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.
990-1007A , Rev ision 2 9/99 10 External Service Bypass Panel ( SBP) Note: The Sm art-UPS DP must only be conn ected by service bypass panels (SBPs) man ufactured by APC. If SBP s other than th ose manufactured by A PC are us ed, the UPS s yst em m ay be damaged and the w ar ranty give n by AP C is re pealed.
990-1007A , Rev ision 2 9/99 11 UPS N L N L INPUT CABLE SBP MAINS L N PE LOAD L N OUTPUT CABLE SBP SBP L N L N Input cable UPS Output cable UPS Fm Fo 1 2 3 4 MBS CONTROL SBP CABLE X010 1 2 3 4 Externa.
990-1007A , Rev ision 2 9/99 12 Standard S ystem With Is olating Trans form er (400 V) And SBP System Ma ins Fuse* (Fm ) Input Cable Trans form er Input Cable UPS Output Cable UPS 4kV 16A 3x2.
990-1007A , Rev ision 2 9/99 13 Operating Instructions Switching On F 0 0 1 M a i n s Switch on the m ains fuse on th e rear of the UPS. The Smart-UPS DP will perform a self-check ending w ith the LED display sh owing red/yellow /green, m eaning that th e unit is fu nctioning properly.
990-1007A , Rev ision 2 9/99 14 LEDs The LED bar on the f ront of th e unit gi ves inf ormation by m eans of color and size of the bar. [ MUTE ] Bat tery Oper . Che ck Ba tt er y Green Y ellow No rma l Ope r . Recharging Bat t . [ 100 % ] [ 50 % ] [ 25 % ] [ 75 % ] Overload Red Bypass / Failure The gener al meaning is : Green = Okay .
990-1007A , Rev ision 2 9/99 15 Batteries A utomatic Battery Check The battery test is autom atically carried out every third month, if the au tomatic battery test function is set. The battery tes t starts w hen the batteries are fu lly ch arged. There is no alarm given for the battery operation and the dis play sh ow s norm al operation.
990-1007A , Rev ision 2 9/99 16 Sp ecifications SUDP4000I SUDP 6000I SUDP8000I SUDP10000I Acceptable input v oltage 220/230/240V +10%/-15% no rmal o peration ± 10% by pass operatio n Inpu t v oltage .
990-1007A , Rev ision 2 9/99 17 Regulatory A gency A pprovals N 3 94 B ME 61 geprüfte Sicherheit.
990-1007A , Rev ision 2 9/99 18 A PC Contact Information Internet ht tp : / / www. a p cc . c o m Latin A merica, South A merica Arge ntina................ 0800.9.APCC (0800.9.2722) Mexico ............................... 95.800.804.4283 Brazil........
An important point after buying a device American Power Conversion SUDP8000I (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Power Conversion SUDP8000I yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Power Conversion SUDP8000I - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Power Conversion SUDP8000I you will learn all the available features of the product, as well as information on its operation. The information that you get American Power Conversion SUDP8000I will certainly help you make a decision on the purchase.
If you already are a holder of American Power Conversion SUDP8000I, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Power Conversion SUDP8000I.
However, one of the most important roles played by the user manual is to help in solving problems with American Power Conversion SUDP8000I. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Power Conversion SUDP8000I along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center