® MasterSwitch ™ VM Power Distribution Unit AP9221X166 AP9221EXPX166 Installation and Quick Start Manual.
Thank Y ou! Thank you for selecting the APC MasterSwitch VM (vertical-mount) power distribution unit ( PDU ). It has been designed for many years of reliable, maintenance-free service. APC is dedicated to the development of high- performance electrical power conversion and control products.
i Contents P r e l i m i n a r yI n f o r m a t i o n ..................... 1 Features of MasterSwitch VM 1 Inventory 2 Please recycle 2 I n s t a l l i n gM a s t e r S w i t c hV M .................. 3 Mounting in a NetShelter enclosure 3 Mounting the controller 5 Hardwiring procedure 7 C o n n e c t i n gM a s t e r S w i t c hV M .
.
1 Pr eliminary Information Featur es of MasterSwitch VM American Power Conversion ’ s MasterSwitch VM is a vertically-mounted, stand-alone, network-manageable power distribution unit ( PDU ) designed to accommodate a total of 16 outlets: eight individually-managed outlets and eight always- on outlets.
2 Pr eliminary Information continued Inventory MasterSwitch VM ( AP9221X166 ) comes with the following items: Please r ecycle The shipping materials for MasterSwitch VM are recyclable. Please save them for later reuse or dispose of them appropriately .
3 Installing MasterSwitch VM Mounting in a NetShelter enclosur e MasterSwitch VM comes with rack-mount brackets for mounting in an APC NetShelter enclosure or other standard ( EIA310-D ) 19 -inch rack. T o mount in an enclosure: 1. Align the brackets (provided) with the holes on the rear of the unit.
4 Installing MasterSwitch VM continued Mounting in a NetShelter enclosur e, continued 4. Insert a caged nut above and below a notched hole on a vertical mounting rail at the highest point in your chosen location. 5. Align the mounting holes of the top bracket on the unit with the caged nuts you installed in Step 4.
5 Installing MasterSwitch VM continued Mounting in a NetShelter enclosur e, continued 6. Insert two mounting screws (provided with the enclosure) and secure the top bracket to the enclosure. 7. Insert two caged nuts above and below a notched hole on the vertical mounting rail where the middle and bottom brackets align with the rail.
6 Installing MasterSwitch VM continued Mounting the contr oller , continued 3. Insert caged nuts on the vertical mounting rails at your chosen location. 4. Align the controller ’ s brackets with the caged nuts that y o ui n s e r t e di nS t e p3 . 5.
7 Installing MasterSwitch VM continued Har dwiring procedur e 1. Make sure that the unit is powered off. 2. Unplug any attached equipment to prevent damage if a mistake is made during wiring. 3. Remove the inspection cover on the power inlet end of the unit by removing the top two screws and sliding the inspection cover off of the unit.
8 Connecting MasterSwitch VM Caution MasterSwitch VM does not provide power protection. Therefore, APC does not recommend plugging the unit directly into any unprotected power source, such as a wall outlet. Setting up a single unit 1. Connect the power cord of each device you wish to connect to the outlets on the front of the unit.
9 Connecting MasterSwitch VM continued Setting up multiple units 1. Follow steps 1 – 3 listed “ Setting up a single unit ” on page 8 for the first unit in your configuration. 2. For each succeeding unit to be connected, refer to the figure on page 9 and follow the steps below: a.
10 Quick Configuration Requir ed configuration Y ou must configure the network settings of MasterSwitch VM before it can operate on a network. The required settings are: • IP address of MasterSwitch.
11 Quick Configuration continued Configuring TCP/IP settings, continued Through the Management Card W izard. The MasterSwitch VM controller contains a management card that provides the network interface. The Management Card W izard provides a quick way to configure all management card settings, including TCP/IP settings.
12 Quick Configuration continued Configuring TCP/IP settings, continued 6. Enter the default user name and password: apc , both lowercase. 7. Once the Main menu appears, choose Network. 8. From the Network menu, choose TCP/IP . 9. W ithin the TCP/IP menu: a.
13 Quick Configuration continued Configuring TCP/IP settings, continued Over the Network by ARP . (Address Resolution Protocol) T o configure MasterSwitch VM TCP/IP settings using ARP : 1. Connect the unit to the network. 2. From a command prompt on a computer connected to the local subnet, type arp -s ip_addr_car d mac_car d .
14 Quick Configuration continued Accessing MasterSwitch VM Y ou can access MasterSwitch VM using a W eb browser , Te l n e t , o r SNMP . See the appropriate paragraph below for details. T h r o u g haW e bb r o w s e r . 1. From your W eb browser , enter the System IP address or DNS name, if configured, of the MasterSwitch VM unit.
.
APC W orldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • V isit the APC W eb site to find answers to frequently asked questions (F AQs), to access documents in the APC Knowledge Base, and to submit customer support requests.
An important point after buying a device American Power Conversion AP9221X166 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Power Conversion AP9221X166 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Power Conversion AP9221X166 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Power Conversion AP9221X166 you will learn all the available features of the product, as well as information on its operation. The information that you get American Power Conversion AP9221X166 will certainly help you make a decision on the purchase.
If you already are a holder of American Power Conversion AP9221X166, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Power Conversion AP9221X166.
However, one of the most important roles played by the user manual is to help in solving problems with American Power Conversion AP9221X166. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Power Conversion AP9221X166 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center