Instruction/ maintenance manual of the product BTI-80 A.O. Smith
Go to page of 20
1 PRINTED IN U.S.A. 0803 MODELS BTI-80 AND 100 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE. COMMERCIAL GAS W A TER HEA TER Glass-Lined T ank-type W ater Heater P ART NO.
2 FOREWORD The design of models BTI-80 and 100 comply with the latest version of ANSI Z21.10.3/CSA 4.3 as automatic storage or automatic circulating tank type water heaters. Installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping necessary .
3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDER W A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water .
4 heater meets or exceeds the ASHRAE/IES 90.1b-1999 standards with respect to insulation and standby loss requirement making an insulation blanket unnecessary . WARNING Should you choose to apply an insulation blanket to this heater , you should follow these instructions.
5 (45.7 CM) OR MORE ABOVE THE FLOOR. THIS MA Y REDUCE THE RISK IF LOCA TION IN SUCH AN AREA CANNOT BE A VOIDED. DO NOT INST ALL THIS WA TER HEA TER DIRECTL Y ON A CARPETED FLOOR. A FIRE HAZARD MA Y RESUL T . Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches (7.
6 CAUTION: IF BUILDING COLD WA TER SUPPL Y HAS A BACK-FLOW PREVENTER, CHECK V AL VE OR W A TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF WA TER IN THE HOT WA TER SYSTEM MUST BE PROVIDED. FIGURE 3 CIRCULA TING RETURN LINE CONNECTIONS TEMPERED W A TER LOOP , IF USED, CONNECT TO POINT "A".
7 THERMOMETERS (Not Supplied) Thermometers should be obtained and field installed as shown in Figure 3. Thermometers are installed in the system as a means of detecting the temperature of the outlet water supply . COMBINA TION W A TER (POT ABLE) HEA TING AND SP ACE HEA TING 1 .
8 WIRING DIAGRAM AND SCHEMA TIC - FIGURE 4 HEA TER WIRING All electrical work must be installed in the United S tates in accordance with the latest version of the National Electrical Code ANSI/NFP A No. 70, in Canada, with the latest version of Canadian Electrical Code CSA C22.
9 TABLE 4 - GAS SUPPLY LINE SIZES (IN INCHES)* MAXIMUM CAPACITY OF PIPE IN CUBIC FEET PER HOUR LENGTH NORMAL IRON PIPE SIZES (INCHES) IN INPUT IN THOUSANDS BTU/HR FEET 1/2" 3/4" 1" 1 1/.
10 4 . This appliance is equipped with a device which automatically lights the burner . DO NOT TR Y T O LIGHT THE BURNER BY HAND. 5. W ait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above on this label.
11 SETTING THE W A TER HEA TER TEMPERA TURE A T 120°F (49°C) (APPROX. " " MARK ON F ACE OF THE TEMPERA TURE ADJUSTING DIAL) WILL REDUCE THE RISK OF SCALDS.
12 1. Provide complete combustion of gas. 2 . Cause rapid ignition and carryover of flame across entire burner . 3. Give reasonably quiet operation during ignition, burning and extinction.
13 BLOWER MAINTENANCE For safety and satisfactory operation it is recommended that the blower be checked once a year by a competent service person. 1. MOTOR - The motor is factory oiled and sealed and requires no further maintenance. 2. WHEEL - Wheel must be clean of soot, ash or any other coating which inhibits either rotation or air flow .
14 T ANK CLEANOUT PROCEDURE The following practices will ensure longer life and enable the unit to operate at its designed efficiency: 1. Once a month the heater should be flushed. Open the drain valve and allow two gallons of water to drain from the heater .
15 8. When deliming has been completed, the heater should be flushed for 3 to 5 minutes with fresh water . • Remove the deliming equipment, install the drain valve, open the cold water inlet line and allow water to flow through heater and out drain valve.
16 A hydrogen sulfide (rotten egg) odor may result if water contains high sulfate and/or minerals. Chlorinating the water supply should minimize the problem. (See EXTENDED NON-USE PERIODS). NOTE: Anode must remain installed (except for inspection) to avoid shortening tank life.
17 TROUBLESHOOTING For your safety , water heater service should be performed only by a qualified service technician. Read the GENERAL SAFETY INFORMA TION section first. W ARNING: DO NOT BY -P ASS ANY CONTROLS TO MAKE HEA TER OPERA TE. OPERA TE ONL Y AS WIRED FROM F ACTOR Y .
18 TROUBLESHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualified service technician. Read the GENERAL SAFETY INFORMA TION section first. W ARNING: DO NOT BY -P ASS ANY CONTROLS T O MAKE HEA TER OPERA TE.
19 Model BTI Limited W arranty A. O. Smith Corporation, the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater. 1. THE T ANK If the glass-lined tank in this water hea.
20 5621 W . 1 15TH STREET , ALSIP , IL 60803 PHONE: 1-800-433-2545 F AX: 1-800-433-2515 w w w .hotwater .com E-mail: p art s@hotwater .com REPLACEMENT P ARTS.
An important point after buying a device A.O. Smith BTI-80 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought A.O. Smith BTI-80 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data A.O. Smith BTI-80 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, A.O. Smith BTI-80 you will learn all the available features of the product, as well as information on its operation. The information that you get A.O. Smith BTI-80 will certainly help you make a decision on the purchase.
If you already are a holder of A.O. Smith BTI-80, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime A.O. Smith BTI-80.
However, one of the most important roles played by the user manual is to help in solving problems with A.O. Smith BTI-80. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device A.O. Smith BTI-80 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center