FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-240e MODEL: HI300 07/18/06 Installer : Please complete the details on the back cover and leave this manual with the homeowner . Homeowner: Please keep these instructions for future reference.
Hampton HI300 Wood Cast Insert 2 Thank-you for purchasing a HAMPTON FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the HAMPTON DEALER in your area.
Hampton HI300 Wood Cast Insert 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label For HI300 ................................................. 4 UNIT DIMENSIONS Unit Dimensions ............................................................ 5 INST ALLA TION Before Installing Y our Insert .
Hampton HI300 Wood Cast Insert 4 SAFETY LABEL This is a copy of the label that accompanies your Hampton Insert . We have printed a copy of the contents here for your review . NOTE: Hampton units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Hampton HI300 Wood Cast Insert 5 UNIT DIMENSIONS 17-1/4” 9” 1 1-1/8” 1 1-3/8” 8-1/2" 21-1/2” 30” 30-7/8" 23-1/4” 23-3/4” 42-1/2” 41” 40” 7-3/4” NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section).
Hampton HI300 Wood Cast Insert 6 INST ALLA TION CHIMNEY SPECIFICA TIONS Before installing, check and clean your chimney system thoroughly . If in doubt about its condi- tion, seek professional advice.
Hampton HI300 Wood Cast Insert 7 Clearance Diagram for Installations Side and T op facing is a maximum of 1.5" thick. Floor protection must be non-combustible, insula- tive material with an R value of 1.1 or greater . * Hearth thickness of 0.5" with k value = 0.
Hampton HI300 Wood Cast Insert 8 FLUE CONNECT OR BRACKET Package contains: 3 brackets and 6 screws. These brackets are to be used to hold the fl ue liner (not supplied) to the Insert and keep the connection. The brackets are screwed into the top of the Insert in the pre-punched holes and then screwed into the fl ue liner .
Hampton HI300 Wood Cast Insert 9 1) Positive Flue Connection with Cleanout 2) Direct Flue Connection with Cleanout 3a) Full Flue Liner (No Cleanout Required) Note: A clean-out door is sometimes required, by your inspector , to be installed when either the Positive fl ue connection or Direct fl ue connection method is used.
Hampton HI300 Wood Cast Insert 10 INST ALLA TION CAST F ACEPLA TE INST ALLA TION 3) Place Mantel T op onto the top of the fi rebox. Mantel T op 2) Secure the Left and Right Side Faceplate to the fi rebox by aligning the Mounting Holes with the Side Mounting Brackets taking care to align vertically while each side rests on the hearth.
Hampton HI300 Wood Cast Insert 11 5) Mount the T op Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate thru the Retainers in the T op Faceplate. NOTE: Slowly lower the T op Faceplate into position; being careful not to damage the Mantel T op.
Hampton HI300 Wood Cast Insert 12 Backside of Fan Facia Shown. Y our fan should only be installed once the unit is in place in order to prevent any damage to the fan.
Hampton HI300 Wood Cast Insert 13 Pull Open Push Closed hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer . A tighter fi t will ensure the tube will not move when the unit is burning.
Hampton HI300 Wood Cast Insert 14 9) During the fi rst few hours it may be more diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if applicable), your draft will increase. 10) For those units installed at higher elevations or into sub-standard masonry fi replaces, drafting problems may occur .
Hampton HI300 Wood Cast Insert 15 ASH DISPOSAL During constant use, ashes should be removed every few days. Please take care to prevent the build-up of ash around the start-up air housing located inside the fi rebox, under the loading door lip. DO NOT ALLOW ASHES TO BUILD UP TO THE LOADING DOORS.
Hampton HI300 Wood Cast Insert 16 DOOR GASKET If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Hampton dealer .
Hampton HI300 Wood Cast Insert 17 LA TCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fi res. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal.
Hampton HI300 Wood Cast Insert 18 HI300 MAIN ASSEMBL Y Part # Description 1) 942-681* Right Side Cast 936-238 Side Cast Gasket 2) 300-021 Flange Adaptor 3) 942-691* Ashlip 4) 300-006 Fan Clip 5) 300-0.
Hampton HI300 Wood Cast Insert 19 HI300 CAST F ACEPLA TE Part # Description 300-921 Cast Faceplate - Metallic Black 300-925 Cast Faceplate - T imberline Brown 300-926 Cast Faceplate - Enamel Black 200.
Hampton HI300 Wood Cast Insert 20 P ARTS LIST HI300 BRICK P ANELS Part # Description 180-960 Brick Set - Complete.
Hampton HI300 Wood Cast Insert 21 NOTES.
Hampton HI300 Wood Cast Insert 22 NOTES.
Hampton HI300 Wood Cast Insert 23 W ARRANTY Hampton Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd.
Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _______________________________________________________.
An important point after buying a device Hampton Direct HI300 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hampton Direct HI300 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hampton Direct HI300 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hampton Direct HI300 you will learn all the available features of the product, as well as information on its operation. The information that you get Hampton Direct HI300 will certainly help you make a decision on the purchase.
If you already are a holder of Hampton Direct HI300, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hampton Direct HI300.
However, one of the most important roles played by the user manual is to help in solving problems with Hampton Direct HI300. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hampton Direct HI300 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center