Instruction/ maintenance manual of the product AD1200EXP American Dynamics
Go to page of 28
AD1200EXP MCS Hard-wire Controller Expander Installation Instructions The manual describes the installation procedures for the American Dynamics AD1200EXP MCS Hard-wire Controller Expander. Before installation, become familiar with all of the special features and warnings associated with this equipment.
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
T able of Contents DESCRIPTION............................................................................................................................ 1 FEATURES .....................................................................................
1 AD1200EXP DESCRIPTION DESCRIPTION The AD1200EXP Hardwired Controller Expander increases the number of pan/tilt sites controlled from a single AD1200A Hard-wired Controller from one to four. Cascading multiple AD1200EXP units increases the number of pan/tilt sites available from four to a maximum of sixteen.
2 INSTALLATION Front Panel Description Site Selection Pushbuttons: Four spring-loaded pushbuttons select the individual pan/tilt unit the operator wishes to control (see Figure 2).
3 AD1200EXP INSTALLATION Figure 3 - AD1200EXP Rear Panel Layout 14- P in C onne c ter s ( 4) 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 1 2 3 Gr ound C onne c ti on 4 .
4 Mounting The AD1200EXP is suitable for desktop operation or mounting in a standard EIA rack. The American Dynamic's AD2117/21 Rack Mount Hardware Kit is recommended for mounting one or two AD1200EXPs in a standard EIA rack. Power The AD1200EXP is configured for use with 24VAC power.
AD1200EXP INSTALLATION 5 A D1200EX P 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 AUT O SC AN 120V 60Hz LEN S ADJ UST AUX P/ T A/ P LEN S U D R L 1 2 H.
Cascading Multiple AD1200EXP Units Multiple AD1200EXP units are used to increase the number of pan/tilt sites available to a single AD1200A Hard-wired Controller from four to a maximum of sixteen. Each AD1200EXP unit is provided with one 5-pin strap harness for cascading purposes.
7 AD1200EXP INSTALLATION 1 2 3 4 0 1 2 3 G A D1200EX P 1 2 3 4 0 1 2 3 G 0 1 2 3 G 1 2 3 4 C ha ssis G r ound C onne c ti on ( 1 8 AWG S o l i d Wi re) to AD1200A H a rd- w i r e Cont r oll e r C ha s.
8 Powering Multiple AD1200EXP Units Connecting multiple (maximum of 4) AD1200EXP units to one AD1200A Controller requires the use of an external 120VAC to 24VAC step-down transformer. NOTE: Connecting multiple AD1200EXPs for European operation requires the use of a 230VAC to 24VAC step-down transformer.
9 AD1200EXP INSTALLATION AUT O SC A N 120V 60Hz LEN S ADJ US T AUX P/T A/P LEN S U D R L 1 2 H R C I F Z CP 1 2 3 4 OF F A D1200A Ha r d- w ir e C ontr olle r A D1200EX P Un it #1 24VAC CO MMO N 24VAC.
10 Connecting Multiple AD1200EXP Units A maximum of four AD1200EXP units may be connected to one AD1200A Hard-wired Controller. All AD1200EXP units connect to the AD1200A Hard-wired Controller via a single 14-pin connector (provided with the AD1200 Hard-wire Controller).
11 Figure 8 - Multiple AD1200EXP Unit -to- AD1200A Hard-wired Controller Connection AD1200EXP INSTALLATION U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 U D R L.
12 AD1200EXP to Pan/Tilt Site Connection The AD1200EXP provides connection ports to four pan/tilt units via 14-pin connectors. NOTE: The AD1200EXP does not provide power to either the pan/tilt or the camera. 1. Using Table 4 as reference, connect each lead from the pan/tilt unit to the appropriate terminal of the 14-pin connector (see Figure 9).
13 AD1200EXP INSTALLATION 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 12 3 4 A D1200EX P U D R L 1 2 R C I F Z N C N C N C A D1240 P a n/ T ilt U D R L 1 2 R C I F Z N C N C N C 1 ZOOM FOCUS I.
14 CCTV Switcher System Connection AD1200EXP units provide a 5-pin connector for use with CCTV switcher systems. Each AD1200EXP unit is provided with one 5-pin strap harness and two 5-pin mating connectors.
15 AD1200EXP INSTALLATION 120V 60H z 120V 60H z J1 J2 J2 J1 AD 1416L w / Loopi ng Re a r P a ne l M ONIT OR A B CA MERA J3 M ONIT OR AB CA MERA 12 34 56 7 89 1 0 1 1 1 2 1 4 1 5 1 6 13 J3 AD 1416 w / .
16 SETUP 4-Position DIP Switch A 4-position DIP switch configures the AD1200EXP for the number of operational cameras and for use within a CCTV switching system. The 4-position DIP switch is mounted on the AD1200EXP rear panel (see Figure 12). Using Table 8 as reference, read the following descriptions of each of the four DIP switches.
17 AD1200EXP OPERATION OPERATION Single AD1200EXP Unit Operation A single AD1200EXP unit provides operational control to a maximum of four pan/tilt sites. 1. Press the appropriate pushbutton (1-4) to select the desired pan/tilt site (see Figure 13). 2.
.
APPENDIX.
.
A1 AD1200EXP INDEX Cable Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Auxiliary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cascading Multiple AD1200EXP Units . . . . . . . . . . . . . . 6 Connector, 14-Pin .
A2 AD1200EXP DIMENSIONS 1. 74" 44. 5m m 10. 3" 261. 6m m 8. 5" 216m m 12 34 MCS PTZ CONTROLLER EXPANDER.
.
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 800-442-2225 FAX: (914) 6.
An important point after buying a device American Dynamics AD1200EXP (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Dynamics AD1200EXP yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Dynamics AD1200EXP - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Dynamics AD1200EXP you will learn all the available features of the product, as well as information on its operation. The information that you get American Dynamics AD1200EXP will certainly help you make a decision on the purchase.
If you already are a holder of American Dynamics AD1200EXP, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Dynamics AD1200EXP.
However, one of the most important roles played by the user manual is to help in solving problems with American Dynamics AD1200EXP. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Dynamics AD1200EXP along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center