Instruction/ maintenance manual of the product AD142AMBIA Haier
Go to page of 24
Operation & Installation Manual No. 0010572912 A DUCT TYPE AIR CONDITIONER AD142AMBIA AU142AFBIA Please read this operation manual before using the air conditioner .
1 T ABLE OF CONTENTS MALFUNCTION 7-8 CARE AND MAINTENANCE 9-10 INST ALLA TION MANUAL FOR OUTDOOR UNIT 1 1-14 INST ALLA TION MANUAL FOR INDOOR UNIT 15-20 SAFETY PRECAUTIONS 3-5 P AR TS AND FUNCTIONS 6 .
CAUTIONS 2 All electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner .
SAFETY PRECAUTIONS Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " W ARNING" and " CAUTION".
SAFETY PRECAUTIONS 4 CAUTION Do not wash the air conditioner with water . Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed.
SAFETY PRECAUTIONS 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on PC board is broken please change it with the type of T3.15A /250V AC. 4. The wiring method should be in line with the local wiring standard.
P AR TS AND FUNCTIONS Indoor Unit Outdoor Unit 6 Air inlet Air outlet Drain hose Connecting piping and electrical wiring 14 Motor(inside) Fan(inside) Air outlet gille Evaporator.
please check the following things about your air conditioner before making a servie call. MALFUNCTION Flickering F1 Note: This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required.
8 MALFUNCTION The followings are not malfunction Shuru Shuru When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo".
9 CARE AND MAINTENANCE Points to observe T urn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. ON OFF Thinner Do not use! Benzine T ooth powder Cleaning 1. Clean the air filter by lightly tapping it or with the cleaner .
10 "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. W ait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.
For inspection and maintenance When you change your address or the installation place Electric work Confirm the following items for safe and comfortable use of air conditioner . The installation work is to be burden on the sales dealer , and do not conduct it by yourself.
12 INST ALLA TION MANUAL FOR OUTDOOR UNIT Edging (2) Installation where the ar ea with strong winds. Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction. (1) Open space requir ement around the unit 2. Selection of the place of installation 1.
13 INST ALLA TION MANUAL FOR OUTDOOR UNIT (1) Outline piping 4. Refrigerant piping (2) Piping size (3) Limitations for one way piping length and vertical height differ ence. One way piping length: less than 15m. V ertical height difference: Less than 5m.
14 INST ALLA TION MANUAL FOR OUTDOOR UNIT 7 90 for 6 sec. 4 (5) Purging method ( the refrigerant is R407C) If it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder .
15 INST ALLA TION MANUAL FOR INDOOR UNIT 1. Safety precautions W ARNING Please read these "Safety Precautions" first then accurately execute the installation work.
16 INST ALLA TION MANUAL FOR INDOOR UNIT NOTICE All W iring of this installation must comply with NA TIONAL, ST A TE AND LOCAL REGULA TIONS . These instructions do not cover all variations for every kind of installation circumstance.
17 INST ALLA TION MANUAL FOR INDOOR UNIT (4) Preparation for suspending the unit 22 990 100 55 225 123 1024 452 225 Standard pressure 0 Pa , Middle pressure 50Pa 1.0m (use white motor plug) 5.0m(use red motor plug) The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 1.
18 INST ALLA TION MANUAL FOR INDOOR UNIT 28 B C Air outlet grille T op panel of unit C amplified Use screw to fix top panel (Figure 6) B Air supply passage Rivet Unit M8 screw nut M8 wide expansion sc.
19 INST ALLA TION MANUAL FOR INDOOR UNIT W all Outside Slant Drain hose (user self-provided) VP30 As large as possible (about 10cm) Downward slant over 1/100 S-shaped bend 1m~1.5m Downward slant over 1/100 Supporting frame Thermal insulation material (user self-provided) Requirements: The indoor side drain hose should be thermal insulated.
INST ALLA TION MANUAL FOR INDOOR UNIT 20 W arning ! During installation, if refrigerant leakage occurs, please immediately take ventilation measure. If the refrigerant gas meet the fire, it may generate poisonous gas. After finishing installation work, please make sure there is no refrigerant leakage.
21 INST ALLA TION MANUAL FOR ELECTRIC WIRING 1 2 3 5. Electric wiring 1(L) Cautions: Use copper wire only .Parameters of connecting line : H05RN-F 4G0.75mm 2 ; Parameters of power supply line : H07RN-F 3G2.5mm 2 . Power supply :1PH,220-230V~,50Hz, connect from outside.
22 INST ALLA TION MANUAL FOR WIRE CONTROLLER 1.Remove the upper cover of wire contr oller The PC board is installed on the back cover of wire controller .
23 CHECK AND TEST RUN Other instruction 1.Set of the air sending of the fan motor Before leaving factory , the rotation speed of fan motor has already been set at standard choice. When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at standard choice.
An important point after buying a device Haier AD142AMBIA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Haier AD142AMBIA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Haier AD142AMBIA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Haier AD142AMBIA you will learn all the available features of the product, as well as information on its operation. The information that you get Haier AD142AMBIA will certainly help you make a decision on the purchase.
If you already are a holder of Haier AD142AMBIA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Haier AD142AMBIA.
However, one of the most important roles played by the user manual is to help in solving problems with Haier AD142AMBIA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Haier AD142AMBIA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center