M31SL / M50SL / M75SL Installa tion/Oper a tor Manual W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
2 American Dryer Corp. 1 13431 - 10 “IMPORT ANT NO TE T O PUR CHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer .
1 13431 - 10 www .amdry .com 3 T able of Contents ________ List of Acronyms _____________________________ H V A C Heating, V entilating, and Air-Conditioning in wc Inches of Water Column L.C.D. Liquid Crystal Display L.E.D. Light Emitting Diode L .P .
4 American Dryer Corp. 1 13431 - 10 Safety Precautions ____________________ Warning For your safety , the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury , or loss of life.
1 13431 - 10 www .amdry .com 5 The “Cool Down” Cycle of tumble dryers should be used to reduce the temperature of the items. They should not be removed from the tumble dryer or piled or stacked while hot.
6 American Dryer Corp. 1 13431 - 10 M31SL Specifications _______________________________________________________________ M AXI M UM CAP ACI T Y ( DRY WEI G H T ) 3 0 l b 13.61 kg T U MBLER DI AM ET ER 3 0 ” 76. 20 cm T U MBLER DEPT H 2 7 ” 68. 58 cm T UM BLE R VOLU ME 11 .
1 13431 - 10 www .amdry .com 7 M31SL Specifications _______________________________________________________________.
8 American Dryer Corp. 1 13431 - 10 M50SL Specifications _______________________________________________________________ ! Shaded areas are stated in metric equivalents 4/30/07 Note The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
1 13431 - 10 www .amdry .com 9 M50SL Specifications _______________________________________________________________.
10 American Dryer Corp. 1 13431 - 10 M75SL Specifications _______________________________________________________________ M AXI M UM CAP ACI T Y ( DR Y WEI G H T ) 7 5 l b 34. 02 kg T U MB LER DI AMET ER 3 7 ” 93. 98 cm T U M B L E R D E P T H 35- 1/2 ” 90.
1 13431 - 10 www .amdry .com 1 1 M75SL Specifications _______________________________________________________________.
12 American Dryer Corp. 1 13431 - 10 Unpacking/Setting Up _________________ Remove protective shipping material (i.e., plastic wrap and optional shipping box) from the dryer . Impor tant Dryer must be transported and handled in an upright position at all times.
1 13431 - 10 www .amdry .com 1 3 Domestic Type I (M31SL, M50SL Only) ! ! ! ! A = 10-inches (25.4 cm) B = 11-inches (27.94 cm) EXAMPLE: For a bank of 4 M31SL dryers, 2 unrestricted openings measuring 10-inches by 1 1-inches (25.4 cm by 27.94 cm) are acceptable.
14 American Dryer Corp. 1 13431 - 10 ! NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction.
1 13431 - 10 www .amdry .com 1 5 Impor tant No more than 4 dryers should be connected to 1 main common duct. The illustration below shows the minimum cross-sectional area for multiple dryer round or square venting.
16 American Dryer Corp. 1 13431 - 10 Electric Models Only All electrically heated dryers must be connected to the electric service shown on the dryer’s data label.
1 13431 - 10 www .amdry .com 1 7 Grounding A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO.
18 American Dryer Corp. 1 13431 - 10 ! ! Gas Infor mation _______________________ It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination.
1 13431 - 10 www .amdry .com 1 9 Ga s S p e c ific a tio n s fo r C E Ap p r o v e d D ry e rs ** Model Gas Ty p e Nom in al Heati n g V alue Suppl y Pressure Gros s Heat I n put Fuel Consumpt ion O r.
20 American Dryer Corp. 1 13431 - 10 Piping/Connections CE and Australian dryer connections will be B.S.P .T ., all others will be N.P .T . There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing.
1 13431 - 10 www .amdry .com 2 1 Conv er ting fr om One F amil y of Gas to Another ______________________ Warning (CE Dr yers) This appliance must only be operated with the gas type indicated on the dryer’s data plate.
22 American Dryer Corp. 1 13431 - 10 ! ! ! R e gulated Gas V alve Refer to “Gas Pressure Adjustment” on this page to adjust the gas valve to the appropriate burner pressure listed on page 19. The supply pressure must also match what is listed on page 19 for the type of gas to be used.
1 13431 - 10 www .amdry .com 2 3 ! ! Gas Pressur e T esting _________________ For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown on page 19. Provisions are made at the gas valve for taking gas pressure readings.
24 American Dryer Corp. 1 13431 - 10 ! ! ! ! ! ! Steam Requirements – High Pressure Shaded areas are stated in metric equivalents * The minimum operating pressure for optimum results is 100 psig (689.
1 13431 - 10 www .amdry .com 2 5 ! ! ! Optional Manual Bypass Provisions are made in the dryer’s fire suppression system for the installation of an optional manual bypass. The connections for the manual bypass are made at the “tee” or “three way” fitting located in the outlet supply side of the water solenoid valve.
26 American Dryer Corp. 1 13431 - 10 ! NOTES ____________________________________ ___________________________________________ ___________________________________________ ______________________________.
1 13431 - 10 www .amdry .com 2 7 Ser vice/Par ts Infor ma tion ____________ Ser vice Service must be performed by a qualified trained technician. If service is required, contact the reseller from whom the equipment was purchased. If the reseller cannot be contacted or is unknown, contact the Service Department for a reseller in your area.
28 American Dryer Corp. 1 13431 - 10 Routine Maintenance _________________ Cleaning A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system.
1 13431 - 10 www .amdry .com 2 9 CE Label Data Label Infor mation _____________________________________________________________ Standard Label When contacting ADC, the information on the data label is required to ensure proper service/parts assistance.
ADC Part No. 1 13431 10 - 06/ 04/ 0 8 - 10.
An important point after buying a device American Dryer Corp. M31SL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Dryer Corp. M31SL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Dryer Corp. M31SL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Dryer Corp. M31SL you will learn all the available features of the product, as well as information on its operation. The information that you get American Dryer Corp. M31SL will certainly help you make a decision on the purchase.
If you already are a holder of American Dryer Corp. M31SL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Dryer Corp. M31SL.
However, one of the most important roles played by the user manual is to help in solving problems with American Dryer Corp. M31SL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Dryer Corp. M31SL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center