Instruction/ maintenance manual of the product GX2300CE Hafler
Go to page of 44
.
.
– 1 – T able of Contents DECLARA TION OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 2 – Declaration of Conformity Application of Council Directive: 73/23/EEC (low voltage directive) Application of Council Directive: 89/336/EEC (EMC Directive) Standard(s) to which Conformity is .
– 3 – NOTICE - IMPOR T ANT SAFETY INFORMA TION 1. READ INSTRUCTIONS All the safety and operating instructions of your Hafler equip- ment should be read before power is applied to the equipment. 2. RET AIN OWNER'S MANUAL These safety and operating instructions should be retained for future reference.
– 4 – ADVER TENCIA – INFORMACION DE SEGURIDAD IMPOR T ANTE El símbolo de flecha relámpago dentro de un triángulo equi- látero, es para alertar al usario de la presencia de “voltajes peli- .
– 5 – ACHTUNG – WICHTIGE SICHERHEITS – INFORMA TIONEN 1. INSTRUKTIONEN LESEN Alle Sicherheits- und Operationshinweise Ihres Hafler Equipments sollten vor der Inbetriebnahme gelesen werden. 2. BETRIEBSANLEITUNG AUFBEWAHREN Bewahren Sie die Bedienungsanleitung sorgf ä ltig auf, damit Sie in dieser auch in Zukunft nachschlagen k ö nnen.
– 6 – A TTENTION: INFORMA TIONS IMPORT ANTES DE S É CURIT É 1. LIRE LES INSTRUCTIONS Le mode d'emploi et les mesures de s é curit é de votre é quipement Hafler devraient ê tre consult é s avant sa mise en marche.
– 7 – NOT ARE – IMPORT ANTI INFORMAZIONI SULLA SICUREZZA 1. LEGGETE LE ISTRUZIONI T utte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all'apparato.
– 8 – All measurements taken at Normal Operating Conditions (i.e. 1/8th rated output power) unless noted otherwise. POWER RA TING: 8 Ω 20-20kHz @ 0.1% THD 300W x 2 CH 600W x 2 CH 4 Ω 20-20kHz @ 0.2% THD 300W x 2 CH 600W x 2 CH 2 Ω 20-20kHz @ 0.
The Hafler GX2300 and GX2600 amplifiers are two rack height, two channel, fan-cooled professional power amplifiers suitable for use in the most demanding sound reinforcement and commer cial sound installations.
– 10 – WHAT ELSE DISTINGUISHES THESE AMPLIFIERS? Constant power into varying impedance. It takes twice as much current to develop a given wattage into 2 Ω as it does into 8 Ω — but only half the voltage.
– 11 – 1. Recessed Front Panel - Prevents switches and controls from acci- dentally being adjusted or broken. 2. Power Switch - T urns the amplifier ON and OFF 3. Power LEDs - V erifies that the amplifier channel is ON 4. Status LEDs - Displays the status of the amplifier .
The GX2300/2600 is a standard 2U (2 rack height) 19" rack-mount unit, with both front and rear rack mounting ears. In portable systems, the amplifier must be supported at both the front and rear . COOLING The GX2300/2600 uses forced-air cooling (fan cooling) to remove the heat produced during normal operation.
– 13 – AUDIO GROUND CHASSIS/FLOAT SWITCH In general, the Audio Ground of each amplifier should be connected to AC mains earth ground A T ONE POINT ONL Y - either through the Chassis (by selecting .
– 14 – The amplifier will operate with either a balanced or unbalanced signal source. INPUT The input jacks used on the GX2300/2600 are dual function connectors which accept 1 / 4 " TRS (T ip Ring Sleeve) or male XLR plugs.
– 15 – FLOATED SOURCE EQUIPMENT Source units with a 2-pin mains power cord have no means to connect the audio output ground to earth ground, so usually the audio output ground is floated from earth ground. However , this does not insure that when installed in a system, the audio output ground will remain floated from earth ground.
– 16 – DELAY (One of these switches must be selected. If all the switches are OFF , there will be no output signal.) The delay feature provides five sections of 2nd-order all-pass delay filters of 450µsec +/-10µ sec each.
– 17 – LEVEL CONTROLS The gain for each channel can be controlled individually using the front panel level control. The controls have 32 detented positions that are calibrated in dB.
– 18 – LOAD SWITCH The Load Switch - located on the front panel - allows the amplifier power supply to be matched to the speaker load for more efficient, cooler running operation.This unique feature of the GX2300/2600 allows each channel to be configured for 2 Ω , 4 Ω , 8 Ω , or 70V , 100V mono operation.
– 19 – 1. Connect signal from source to both CH A and CH B inputs. 2. Move Stereo/Biamp switch to Stereo input mode. 3. Move Stereo/Mono switch to Stereo mode. 4. Select desired speaker load (8 Ω /4 Ω /2 Ω ) for each channel – CH A & CH B loads do not need to match.
– 20 – 1. Connect signal from source to CH B input. 2. Stereo/Biamp switch not active (Stereo/Mono switch overrides this switch when in mono/70V/100V mode).
– 21 – 1. Connect signal from source to CH B input. 2. Stereo/Biamp switch not active (Stereo/Mono switch overrides this switch when in mono/70V/100V mode).
– 22 – Hafler offers a limited warranty on Hafler products on the following terms: • Length of W arranty 5 years on GX2300 & GX2600 • What is Covered This warranty applies only to products sold to the original owner (non-transferable). This only applies to units sold in the Continental United States.
– 23 – PC BOARD LA YOUTS X70 X69 X68 X67 X65 X64 X63 X62 X61 X60 X53 X6 X2 X9 X51 X66 X50 X49 X36 X34 X23 X22 X57 X56 X55 X48 X47 X46 X45 X44 X52 X42 X41 X28 X26 X27 X30 X31 X29 X38 X39 X32 X33 X3.
– 24 – J9 J10 J16 J3 J5 J1 C5 C3 C2 R2 L2 L1 L3 C6 C1 C4 R3 C7 R1 J12 J11 R4 J8 J15 J13 J7 J6 J14 DANGER - HIGH VOLTAGE 230V 230V 120V 120V ORG ORG WHT WHT BLACK BLACK KS4R PC-2460-E HAFLER J4 J2 .
– 25 – PC BOARD LA YOUTS TIME DELAY/PHASE INVERTER.
– 26 – BRIDGE RECTIFIER Schematic Diagrams.
– 27 – PC-2460-e.sch-1 EMI FILTER.
– 28 – CROSSOVER CD EQ Schematic Diagrams.
– 29 – TIME DELAY/PHASE INVERTER.
– 30 – AMPLIFIER.
– 31 – C600_maualB.sch-1.
– 32 – PROTECTION.
C600_maualB.sch-2 – 33 –.
G – 34 – HIGH VOLTAGE CONTROL.
– 35 – GX 2300.
– 36 – HOUSEKEEPING CONTROL.
– 37 – C600_maualB.sch-6.
– 38 – INPUT.
– 39 – C600_maualB.sch-8.
– 40 – POWER.
– 41 – C600_maualB.sch-5.
A DIVISION OF ROCKFORD CORPORA TION 546 SOUTH ROCKFORD DRIVE TEMPE, ARIZONA 85281 U.S.A. IN U.S.A. (480) 967-3565 / IN CANADA, (604) 942-1001 IN EUROPE, F AX 8503-9340-14 / IN JAP AN, F AX (81) 559-79.
An important point after buying a device Hafler GX2300CE (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hafler GX2300CE yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hafler GX2300CE - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hafler GX2300CE you will learn all the available features of the product, as well as information on its operation. The information that you get Hafler GX2300CE will certainly help you make a decision on the purchase.
If you already are a holder of Hafler GX2300CE, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hafler GX2300CE.
However, one of the most important roles played by the user manual is to help in solving problems with Hafler GX2300CE. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hafler GX2300CE along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center