Series FR566G Deluxe Clinical Care R ec liner Series FR566DG Deluxe Clinical Care R ec liner with Drop Ar m Series FR566GH Deluxe Clinical Care R ec liner with Heat and Massage Series FR566DGH Deluxe .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 2 CONTENTS .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 3 INTR ODUCTION This manual contains assembly , operation, and maintenance instructions for Lumex Clinical Car e Recliners Series FR566G, FR566DG, FR566GH and FR566DGH.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 4 .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 5 ASSEMBL Y UNP ACKING 1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field authorized distributor .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 6 F eatures, FR566DG and FR566DGH upholstered back upholstered armrest upholstered seat upholstered legrest / .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 7 Upholstered Back Assembly , All Models bracket and link to be even threaded knob through lar ge hole in bayo.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 8 OPERA TION .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 9 side table (stored position) side table (engaged position) tabs engage into slots on side table mount bracke.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 10 SIDE P ANEL OPERA TION For easy cleaning and access to the side and underside of the r ecliner , Lumex Clinical Car e Recliners featur e easy-to-r emove side panels.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 11 RECLINER OPERA TION, ALL MODELS The Lumex Series FR566G / FR566DG / FR566GH / FR566DGH r ecliners featur e thr ee positions for patient comfort. The four th position is a T rendelenbur g (or Shock Position) that must be activated by a car egiver .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 12 T hird Position The thir d position is the Second Recline Position and is also known as the “Full Recline” position. This position is ideal for patient tr eatment, r est and r eading.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 13 DROP ARM FUNCTION, FR566DG AND FR566DGH ONL Y The Lumex Deluxe Clinical Car e Recliner with Dr op Arm (Series FR566DG and FR566DGH) featur es self-storing dr op arms that ar e simple for the car egiver to actuate.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 14 L UMEX CLINICAL CARE RECLINERS WITH HEA T AND MASSA GE FEA TURE INST ALLA TION AND OPERA TING GUIDE Series .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 15 selector switch Selector Switch (Mounted Under neath Right Ar mrest) Connection The Heat and Massage Unit comes pr e-installed in Lumex Clinical Car e Recliners with the Heat and Massage Option (FR566GH and FR566DGH).
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 16 Heat and Massage Unit Setup Instr uctions 1. Place the back cushion over the vertical bayonet lugs of the r ecliner mechanism. Secur e back on each side with the thr eaded scr ew knobs enclosed with the Recliner Operating Instructions, as shown at right.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 17 Heat and Massage Unit Operation Instr uctions 1. Plug the power supply cor d into any gr ounded outlet.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 18 Heat and Massage Unit T roubleshooting Guide The cables and connections need to be validated. This will r equir e the ser vices of a maintenance person and a clear working ar ea.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 19 CARE AND MAINTENANCE .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 20 The information published in this car e guide r efers to the performance of PERMABLOK3® pr oducts in specic tests conducted under laborator y conditions. Results may var y under actual conditions.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 21 • Deter gent and water are adequate for cleaning surfaces in nonpatient-car e areas (e.g., administrative ofces). Clean and disinfect high-touch surfaces on a more fr equent schedule than minimal-touch housekeeping surfaces.
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 22 TECHNICAL SPECIFICA TIONS .
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 23 LIMITED WARRANTY GF Health Pr oducts, Inc. ("Graham-Field") warrants the FR566G Deluxe Clinical C.
GF Health Pr oducts, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 USA T elephone: 770-368-4700 Fax: 770-368-2386 T echnical Suppor t: 770-447-1609 www .
An important point after buying a device Graham Field fr566g (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graham Field fr566g yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graham Field fr566g - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graham Field fr566g you will learn all the available features of the product, as well as information on its operation. The information that you get Graham Field fr566g will certainly help you make a decision on the purchase.
If you already are a holder of Graham Field fr566g, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graham Field fr566g.
However, one of the most important roles played by the user manual is to help in solving problems with Graham Field fr566g. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graham Field fr566g along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center