Operation HTX 2030 -For P ortable Airless an d Air-Assiste d Spraying of W ater -Based Ar chitectural Coatin gs with Base Coat Pump- -For Airless Spra ying Archit ectural Coatings and Paint s with T op Coat Pump- Model Number: 257369 Maxim um W orking Pressure: Base Coat Pump: 1000 psi (69 bar , 6.
Contents 2 313888B Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W arning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Produc t Overview . . . . . . . . . . . . . . . . . . . . . . . .
Warning 313888B 3 Wa r n i n g The f ollowing warnings are for t he setup, use, groundi ng, maintenance, and repair of this equipment. The exc lamation point symbol alerts you to a general warnin g and the hazard symbol ref ers to pr ocedure-spe- cific risk.
Warning 4 313888B PRESSURIZED ALUMINUM P ARTS HAZARD Do not use 1,1,1-trichloroethane, me thylene ch lor ide, other halogenated hydrocar bon solvents or fluids containing such solv ents in pressurized alum inum equipment.
Product Overview 313888B 5 Pr oduct Over vie w HTX 2030 with Base Coat Pump (257369) The HTX 2030 Spra yer comes equ ipped with a Base Coat Pump 24B321.
Product Overview 6 313888B T op Coat Pump (Kit 24B140) The pump on the HT X 2030 Spra yer ca n also be s witch ed out with a T op Coat Kit 24B140 (purc hased separately) .
Component Identification - Sprayer 313888B 7 Component Identification - Spra yer ti14415a 1 2 3 4 5 7 8 11 10 9 6 T op Coat Kit 8 12 1 ON/OFF Switch 2 Prime Switch (used with Base Coat Pump) 3 Pump Co.
Component Identification - Base Coat Applicator 8 313888B Component Identification - Base Coat Applicator ti14357a 1 2 3 4 5 6 9 10 7 8 11 1 Applicator 2 Air Hose Adapter and Air Adjustment V alve 3 A.
Pressure Relief Procedure 313888B 9 Pressure Relief Pr ocedure Applicator (Base Coat Pump) 1. T ur n engine OFF . 2. T ur n on/off switch OFF and tur n pre ssure control knob fully counterclockwise. 3. T ur n prime/drain v alve down to DRAIN position.
Start Engine 10 313888B Star t Engine 1. Mov e fuel v alv e to OPEN. 2. Move choke to CLOSED . 3. Set thrott le to F AST . 4. Set engine switch to ON. 5. Pull star ter rope. 6. After engine st ar ts , mov e choke to OPEN. 7. Set throttle to desired setting.
Setup 313888B 11 Setup 1. Fill mixing pail with pre-mi xed te xture material. Mix per material manuf acturer instructions. Add approxim ately 10% water to te xture mix or per materia l manufacturer instr uctions. Mix thoroug hly. 2. Connect material hose to pump outle t.
Setup 12 313888B 5. T ur n on/off switch OFF and tur n drain valve knob to SPRA Y . 6. T ur n on/off s witch ON, and run pump until a steady stream of ma ter ial flows from mate rial hose. T ur n on/off switch to OFF and tur n drain valv e kno b to DRAIN.
Setup 313888B 13 Air Assisted Spray (Base Coat Applicator) 1. Prepare material, page 11. Place material hose in supply pail. 2. T ur n on/off s witch OFF . 3. Remov e cap before installing air line. 4. T ur n air valv e OFF . Connec t applicator to mater ial hose and air hose .
Setup 14 313888B Spray Gun (Top Coat Pump) 1. Lock gun trig ger safety . Inse r t seat an d OneSeal ™ . Inser t SwitchTip. 2. Screw assembly onto gun. Hand tighten. 3. T rigger gun and spra y test patter n. Slowly adjust pressure to eliminate hea vy edges.
Cleanup 313888B 15 Cleanup 1. T ur n on/off s witch OFF . 2. P erform Pressure Reli ef proc edure, page 9. 3. Place pump in pa il of clean water . 4. Shut OFF air if spr aying with ai r . Remov e applicator from mate rial an d air hoses. 5. Base Coat Pump: Disconnect material hose from pump outlet .
Cleanup 16 313888B 9. Run pump un til cleaning ball exits material hose. Sav e cleaning ball (Base Coat On ly). 10. T ur n on/off s witch OFF and turn prime/drain v alve t o DRAIN. Clean outsid e of pump and suction tube with brush and water . 11. Connect applicat or to material hose.
Cleanup 313888B 17 19. Clean hardened material from applicat or nozzles with air nozzle cleaner . ti11810a ti11811a NO TICE Do not use air nozzle cleaner to clean applica tor check v alve or airless spra y tip nozzle. Damage will occur . Remove air chec k valve fr om applicator to c lean hard ened material from interior of applicator .
Digital Tracking System (DTS) 18 313888B Digital T rac king System (DTS) Main Menu Close cov er when spraying to protect disp la y . 1. P erform Star tup steps 1 - 2. • Open drain v alve • T ur n pump control counterclockwise to lo west set- ting • Set applicat or switch to OFF 2.
Digital Tracking System (DTS) 313888B 19 Secondary Menu - Stored Data Mode • Open drain v alve • T ur n pump control counterclockwise to lo west set- ting • Set applicat or switch to OFF 1. Star t Engine, pag e 10. Pressure displa y appears . 2.
Digital Display Messages 20 313888B Digital Displa y Messages * Error codes also appear on control board as a blinking red LED . LED is an alter nate to digital me ssages. 1 Remov e two screw s (71) and swing down co ver (130). 2 Star t engine . Blink count is the same as error code(E=0 X).
Maintenance 313888B 21 Maintenance DA I L Y • Check engine oil le vel and fill as necessar y • Chec k hose fo r wear and damage • Chec k that all hose fittings are secure • Chec k gun safet y for prope r operation • Check and fill the gas tank • Chec k lev el of TSL in displacement pump pac king nut.
Technica l Data 22 313888B T e chnical Data Dimensions Honda GX 200 Engine: ANSI P ower Rating @ 3600 r p m 6.5 Horsepower (4.8 kW) Maximum W orking Pressure: Base Coat Pump 1000 psi (69 bar , 6.9 MPa) T o p Coat Pump 3300 psi (228 bar , 22.8 MP a) Noise Level: Sound P ower 105 dBa per ISO 3744 Sound Pressure 96 dBa measured at 3.
Technical Data 313888B 23.
Graco Standard Warra nty 24 313888B Graco Standar d W arranty Graco warrants all equipment ref erence d in this document which is manufactured b y Graco and bearing its nam e to be free from de fe c t s i n material and workmanship on the date of sale to the origin al purch aser for use.
An important point after buying a device Graco Inc. 313888B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Inc. 313888B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Inc. 313888B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Inc. 313888B you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Inc. 313888B will certainly help you make a decision on the purchase.
If you already are a holder of Graco Inc. 313888B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Inc. 313888B.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Inc. 313888B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Inc. 313888B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center