Instructions–Parts List 306706W ST A TIONAR Y AIRLESS P AINT SPRA YER 30:1 President R Hydra–Spray R Used for airless spray application of paints and other coatings from a 50–gallon drum. 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure 100 psi (0.
2 306706 T able of Contents W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Grounding 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 6 . . . . . . . . . .
306706 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment.
4 306706 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
306706 5 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 6.
6 306706 Installation NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.
306706 7 Installation The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 6.
8 306706 Operation/Maintenance Pressure Relief Procedure SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury .
306706 9 Operation/Maintenance 3. Push in on the air valve knob to lower the elevator , so the cover (A) rests on the top lip of the drum. The support clamp (K) recesses must be tight against the elevator riser tube. The pump intake valve feet (B) must contact and support the perfo- rated plate (9) as shown in Fig.
10 306706 Parts Drawing Model 231063, Series C, 30:1 President R Hydra-Spray R A A A 06218A 31 19 06218 1 2 3 4 5 6a 6b 6c 6d 6e 7 8 9 10 11 12 43, 44 15 46 20 45 21 23 24 25 26 28 29 30 48 31 32 34 3.
306706 1 1 Parts List Model 231063, Series C, 30:1 President R Hydra-Spray R Ref. No. Part No. Description Qty . 1 202295 V AL VE, push-pull See 306287 for parts. 1 2 203743 V AL VE, restrictor See 306287 for parts. 1 3 204385 ELEV A TOR See 306287 for parts.
12 306706 Notes.
306706 13 T echnical Data Ratio 30:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maximum fluid working pressure 3000 psi (21 MPa, 207 bar) . . . . . . . . . . . . . . . .
14 306706 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
An important point after buying a device Graco Inc. 306706W (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Inc. 306706W yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Inc. 306706W - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Inc. 306706W you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Inc. 306706W will certainly help you make a decision on the purchase.
If you already are a holder of Graco Inc. 306706W, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Inc. 306706W.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Inc. 306706W. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Inc. 306706W along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center