Instruction/ maintenance manual of the product 236721 Graco Inc.
Go to page of 16
308–367 Rev . B Supersedes Rev . A and PCN B First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 23:1 RA TIO Monark Sprayers 2760 psi (19.
308–367 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembling the Sprayer 4 . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . .
3 308–367 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . This equipment is for professional use only . Read all the instruction manuals, tags, and labels before operating the equipment.
4 308–367 Assembling the Sprayer Cart Mounted Pump Assemble the suction hose (6) to the elbow (5) at the pump intake. Screw the suction tube (7) onto the other end of the hose. See Fig. 1. Fig. 1 03356 7 6 5 W all Mount Pump 1. Screw the gauges (25) into the air regulators (F , G).
5 308–367 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and parts drawings.
6 308–367 Installation Fig. 4 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regu.
7 308–367 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
8 308–367 Operation Starting and Adjusting the Pump W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. See Fig. 5. Be sure the air regulators (F , G) and bleed- type master air valve (B) are closed.
9 308–367 Operation 03140 Fig. 5 W all Mount Pumps Cart Mounted Pumps Pail Mounted Pumps 40 46 03142 G F H B 18 J 1 26 G B H 7 F G F H 36 03145A.
10 308–367 Parts See Detail. NOTE: Apply thread sealant to all male threads, except at swivel connections. 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 15 (Ref) 16 17 18 19 19 23 24 25 26 28 29 30 31 32 37 47 A A 37 (Ref) 10 Part No.
11 308–367 Parts Part No. 236–721 Cart Mounted Pump Ref No. Part No. Description Qty . 1 100–016 LOCKW ASHER, spring; 1/4” 2 2 100–022 CAPSCREW , hex hd; 1/4–20 x 3/4” (19 mm) long 2 3 1.
12 308–367 Parts 28 23 52 18 24 29 22 51 20 15 16 17 19 18 17 (Ref) B B 31 32 31 10 9 26 39 43 40 41 42 44 45 46 35 36 29 18 13 7 6 25 5 (Ref) 12 34 33 31 32 31 29 50 49 3 4 5 49 7 6 25 49 14 NOTE: Apply thread sealant to all male threads, except at swivel connections.
13 308–367 Parts Part No. 236–722 Pail Mounted Pump Ref No. Part No. Description Qty . 3 171–987 TEE; 3/8 npt(f) x 1/4 npt(f) run; 3/8 npt(f) branch 1 4 156–823 UNION, swivel; 1/4 npt(m) x 1/4 npt(f) 1 5 202–812 HOSE, air; neoprene; 1/4” (6 mm) ID; cpld 1/4 npt(mbe); 1.
14 308–367 Parts Part No. 236–723 W all Mount Pump See Detail. Included with wall bracket (7). B A 5 22 23 (Ref) 7 23 13 3 1 4 9 18 26 11 10 12 3 (Ref) 16 28 15 32 17 17 14 25 7 (Ref) 29 31 32 19 30 34 36 20 21 24 NOTE: Apply thread sealant to all male threads, except at swivel connections.
15 308–367 Parts Part No. 236–723 W all Mounted Pump Ref No. Part No. Description Qty . 1 159–101 HOUSING, suction tube intake 1 3 214–961 HOSE, suction, fluid; nylon 3/4 npt(mbe); 3/4” (19 mm) ID; 6 ft (1.
16 308–367 The Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
An important point after buying a device Graco Inc. 236721 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Inc. 236721 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Inc. 236721 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Inc. 236721 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Inc. 236721 will certainly help you make a decision on the purchase.
If you already are a holder of Graco Inc. 236721, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Inc. 236721.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Inc. 236721. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Inc. 236721 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center