Instruction/ maintenance manual of the product 236-898 Graco Inc.
Go to page of 16
308–332 Rev . D Supersedes Rev . C and PCN D First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. ST AINLESS STEEL, 15:1 RA TIO Monark Sprayers 2700 psi (18.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . .
INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed into the eyes or onto the skin can also cause serious injury .
4 308-332 FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 308-332 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4.
6 308-332 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and the parts lists on pages 10–13.
7 308-332 Installation Fig. 3 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regulator G Gun Air Re.
Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
Fig. 4 W all Mount Pumps (Model 236–065) 16 21 34 6 10a 10b 29 Pail Mount Pumps (Model 236–069) 10a 29 10b 6 16 40 1 42 Operation Slowly open the pump air regulator (10b) until the pump starts. Run the pump slowly until fluid comes from the drain valve (6).
10 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 02802A 1 See Detail at left.
11 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
12 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 2 8 9 Apply thread sealant to male threads, except at swivel connections.
13 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
14 308-332 Notes.
15 308-332 T echnical Data Category Data Maximum working pressure 2700 psi (18.5 MPa, 185 bar) Maximum incoming air pressure 180 psi (1.25 MPa, 125 bar) Ratio 15”1 W etted parts: Pump See manual 308.
16 308-332 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
An important point after buying a device Graco Inc. 236-898 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco Inc. 236-898 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco Inc. 236-898 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco Inc. 236-898 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco Inc. 236-898 will certainly help you make a decision on the purchase.
If you already are a holder of Graco Inc. 236-898, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco Inc. 236-898.
However, one of the most important roles played by the user manual is to help in solving problems with Graco Inc. 236-898. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco Inc. 236-898 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center