Instructions - - Parts List 308797R ALUMINUM Hu sky t 716 Air - - op erated Diaphr agm Pumps Used to evacuate and transfer fluids. 100 psi (0. 7 MPa, 7 bar ) Maxim um F luid Work ing Press ure 100 psi (0. 7 MPa, 7 bar ) Maxim um Air I nput Pr essure Par t No.
2 308797 T able of Contents W arnings 2 ...................................... Insta ll ati on 4 ..................................... Oper ation 10 .................................... Maint enance 1 1 .................................. T roubleshoot ing 12 .
3 308797 W ARNING TOXIC FLUID HAZ ARD Hazardous f luid or tox ic fum es can caus e serious injury or deat h if s plashed in t he eyes or on t he skin, inhaled, or swallowed. D Know the s pecif ic hazards of t he fluid you ar e using. D Do not lif t a pum p under press ure.
4 308797 Installation Gener al Infor ma tion D The Typical Ins tallat ions in Fig. 2 ar e only guides for s electing and inst alling syst em co mponents. Contact your G raco dist ributor f or assis tance in planning a system t o suit your needs. D Always use G enuine Gr aco Part s and Ac cess ories.
5 308797 Installation Air Line W ARNING A bleed-t ype mas ter air valv e (B) is r equired in your system t o relieve air tr apped bet ween this valve and the pum p.
6 308797 Installation Fluid Pressure Relief V alve CAUTION Some systems may require in stallat ion of a pressure relief valv e at t he pump outlet t o prevent overpr es- suriz ation and rupt ure of t he pump or hos e. See Fig. 1. Ther mal expansion of f luid in the out let line c an cause o verpressuri zation.
7 308797 Installation KEY AP u m p C Elec tric ally conduc tiv e air supply line D Air line quic k disc onnec t H Fluid drain v alve ( required) K Elec tric ally c onduc tive f luid supply hos e L Fluid suc tion line Y Gr ound wire (r equired; s ee page 8 for ins tallation ins truc tions ) 9074A Fig.
8 308797 Installation Gr ounding W ARNING FIRE AND EXPLOSI ON HAZARD This pump m ust be gr ounded. Bef ore operating t he pump, ground t he system as explained below . A lso read t he sec- tio n Fi re and Exp lo sio n Hazard on page 3. The m etal Husk y 716 pumps hav e a grounding st rip connect ing the v ee clamps (109) .
9 308797 Installation Changing the Or ientation of the Fl uid Inlet and Outlet P orts Fig. 4. Y ou can change t he orient ation of t he fluid inlet and outlet por ts by repos itioning t he manifolds . 1. Reli eve th e pressu re. See Pres- sure Rel ief Pro cedu re on page 10.
10 308797 Operation Pr essure Relief Pr ocedu re W ARNING PRESS URIZ ED EQ UIPM ENT HAZ ARD The equipm ent st ays pr essuriz ed until pr essure is manually r elieved.
11 308797 Main tenanc e Lubri cation The air valv e is lubricat ed at t he fac tory t o operat e without addit ional lubrication. I f you want to provide additional lubr ication, r emove t he hose fr om t he pump air inlet and add t wo drops of mac hine oil to t he air inlet every 500 hour s of operat ion or every mont h.
12 308797 T roubleshooting Read Pressu re Reli ef Pro cedu re on page 10, and rel ieve t he p ressure bef ore you c heck or s ervice the equipm ent. Check all pos sible problems and c auses bef ore disass embling the pum p. PROBLEM CAUSE SOLUTION Pump will not cycle, or cycles once and st ops.
13 308797 Service Air V alve NOT E: Air V alve Repair K it 241657 is av ailable. Par ts inc luded in the kit are mar ked with a dagger ( { ) in Fig. 5 and in the Par ts Drawings and List s. A t ube of gener al purpose greas e 1 1 1920 is supplied in t he kit.
14 308797 Service Ball Check V alves NOT E: Fl uid Sect ion Repair Kit D05977 is av ailable. See page 21 to or der t he correc t kit for your pump. Part s included in t he kit are m arked wit h a double dagger ( } ) in F ig. 6 and in t he Part s Drawings and Lists .
15 308797 Service Fig. 6 } 139 } 201 101 } 202 } 139 } 139 } 201 } 202 } 139 } 301 } 301 105 105 106 106 107 102 102 1 T o r q u et o8 0t o9 0i n - l b( 9t o1 0N S m).
16 308797 Service Dia phragm s NOT E: Fl uid Sect ion Repair Kit D05977 is av ailable. Par ts inc luded in the k it are m arked wit h a double dagger ( } ) in Fig. 7 and in t he Part s Drawings and List s. G eneral purpose gr ease 1 1 1920 and Adhesiv e 1 13500 are supplied in the kit .
17 308797 Service Dia phragm s Fig. 7 11 } Incl uded in Flui d Secti on Repair Kit D05977 1 2 T orque t o 35 to 45 in-lb (4.0 t o 5.1 N-m) . Apply greas e. The wor ds “A IR S IDE” on diaphragm and bac kup diaphr agm must fac e towar d diaphragm s haft (15).
11 4 13 10 } 16 } 139 } 201 134 4 15 } 1 109 101 102 102 } 202 } 139 } 301 108 11 2 11 2 } 401 } 402 103 11 7 105 105 106 106 107 6 133 } 11 5 Grounding D eta il 121 122 123 { 9 8 { 7 { 2 { { Incl ude.
19 308797 241407 and 241408 Part s List Fluid Section Par ts List Ref. No. Part No. Descri pti on Qty 101 185622 COV ER , fluid ; alu minu m 2 102 185624 MANIFOLD; al uminum; NPT 2 103 189220 LABEL, warni ng 1 105 1 12912 SCREW ; 3/8- - 16; 2.25 in. ( 57.
20 308797 T orque Sequence Always f ollow torque s equence when inst ruct ed to t orque f astener s. 1. Left /Right F luid Covers T orque bolts t o 80 - - 90 in- - lb (9 - - 10 N S m). FR ONT VIEW 1 2 2. Inlet Manif old T orque bolts t o 80 - - 90 in- - lb (9 - - 10 N S m).
21 308797 T echnical Data Maximu m f lui d working p ressure 100 p si (0.7 MPa, 7 bar) ........................................... Air pr essure oper ating range 30 to 100 ps i (0.2 t o 0.7 M Pa, 2. 1 to 7 bar ) .............................. Maxim um air consumpt ion 28 scfm ( 0.
22 308797 Husky 716 D imensions 1.38 in. (35.1 mm) FRON T VIEW SIDE VIEW 1/4 npt(f) Air Inlet 6.04 in. (153.4 mm) 7.37 in. (187.2 mm) PUMP MO UNTI NG HO LE P A T TE RN Four 0.28 in. (7.1 mm) Diameter S lots 4.44 in. (1 12.8 mm) 4.25 in. (108.0 mm) 10.
23 308797 Performance Charts 0 20 40 60 80 100 0246 8 1 0 1 2 1 4 1 6 (7.6) (15.2) (22. 7) (30.3) (37. 9) (45.4) (53. 0) (60.6) Fluid Outlet Pr essure T es t Conditions : Pump test ed in wat er wi th i nlet subm erged.
24 308797 Performance Charts 0 5 10 15 20 25 30 0246 8 1 0 1 2 1 4 1 6 (7.6) (15.2) ( 22.7) (30.3) (37.9) (45. 4) (53.0) (60. 6) Air C onsumpti on T es t Conditions : Pump test ed in wat er wi th i nlet subm erged.
25 308797 Notes.
26 308797 Graco Stan dard Hu sky Pump W arran ty Graco w arrant s all equi pment r efer enced in thi s document whi ch is manufact ured by Graco and beari ng its name to be free f rom defect s in mat eri al and workmanshi p on t he dat e of sale to the or igi nal purchaser for use.
An important point after buying a device Graco 308797R (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 308797R yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 308797R - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 308797R you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 308797R will certainly help you make a decision on the purchase.
If you already are a holder of Graco 308797R, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 308797R.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 308797R. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 308797R along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center