Instructions Diesel Exhaust Fluid (DEF) System 3A1189G EN For pumping diesel exhaust fluid. Not approved for use in European explosive atmosp here locations. For professional use only. 50 psi (0.3 MPa, 3.4 bar) Maximum Fluid Working Pressu re 50 psi (0.
Warnings 2 3A1189G Warnings The following general warn ings are for the setup, use, ground ing, maintenance, and repair of this equipme nt. Addi- tional, more specific warnings may be found th ro ughout the body of this manual where applicable. Symbols appea r- ing in the body of the manual re fer to these general warnin gs.
Warnings 3A1189G 3 Pressure Relief Procedure Follow this Pressure Relief Procedure whenever you: • Are instructe d to relieve pressure. • Stop dispensin g. • Check, clean or service any system eq uipment. • Install or clean fluid nozzles. 1. Turn OFF air sup ply to pump ( F IG .
Installation 4 3A1189G Installation Typical Installations Model 24F531 - Wall Mounted, with Meter Model 24F878 - Wall Mounted, no Meter Key AP u m p B Bleed-type master air valve (required for pump) C.
Installation 3A1189G 5 Model 24F947 - Drum Mo unted without Meter Model 24M499 - Drum Mounted with Meter Key AP u m p B Bleed-type master air valve (required for pump) C Air supply li ne D Pump air regulator E Fluid supply hose F Suction kit G Fluid n ozzle J Nozzle tray and bath K Drum bracket L Safety valve - set to 50 psi (3.
Installation 6 3A1189G General Installation Information • The Typical Installation illustrations provided on pages 4 - 5 are only guide lines for installing system components. Contact your Graco distri butor for assistance in planning a system to suit your needs.
Installation 3A1189G 7 Pump For complete pump instruct ions refer to the pump instruction m anual includ ed with your system. • If necessary, change the orienta tion of the fluid inlet and outlet ports on th e pump. See pump instru ction manual for this proced ure.
Installation 8 3A1189G The suction line is designed to allow for full evacuation of the container so it will b end slightly when installed. 1. Connect suction tube (6c) to drum inser t (6b) to pump. 2. Insert suction lin e (6c) into drum. 3. Install drum coupler (6a) into drum insert (6b) 4.
Operation 3A1189G 9 Drum Mounting Bracket (2): Model 24F947 or 24M499 Drum moun ted DEF Sys tem Models 24 F947 or 2 4M499 include a M ounting Bracke t Kit containing the following parts - Scre ws (2a), Screws (2b), Washe rs (2d), Hex Nuts (2e), Mounting Pl ate (2f), Nozzle Bath Holde r (2g), Nozzle Holder Br acket (2h) an d screws (2j) .
Parts 10 3A1189G Parts Wall Mounted with Meter: Model 24F531 Wall Mounted without Meter: Model 24F878 Ref Part No. Description Qty 1 24G745 PUMP, diaphragm, 515, plastic, bsp 1 2 24F870 KIT, pump brac.
Parts 3A1189G 11 Drum Mounted withou t Meter: Model 24F947 Drum Mounted with Meter: Model 24M499 Ref Part No. Description Qty 1 24G745 PUMP, diaphrag m, 515,plastic, bsp 1 2 24F679 KIT, pump bracket, .
Technica l Data 12 3A1189G Bracket (2) Kits 2 - Bracket 24F870: Models 24F531 / 24F878 2 - Bracket 24F 679: Model 24F947 / 24M499 Technical Data 2a SCREW, cap, hex head (not shown) 4 2b SCREW, cap, he.
Technical Data 3A1189G 13 Meter US Metric Flow range 0.5 to 15 gpm 1.9 to 57 lpm Maximum working pressure 50 psi 0.3 MPa, 3.4 bar Minimum workin g pressure 5 psi 34 MPa, 0.3 bar Weight 1.8 lb 0.82 kg Unit of meas urement ( Display shows quantity in 0.
All written and visual data con tained in th is document reflects the latest product info rmation available at the time of publica tion. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English.
An important point after buying a device Graco 24F531 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 24F531 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 24F531 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 24F531 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 24F531 will certainly help you make a decision on the purchase.
If you already are a holder of Graco 24F531, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 24F531.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 24F531. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 24F531 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center