Instruction/ maintenance manual of the product 215963 Graco
Go to page of 12
Instructions – Parts List Fast-Flo R Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure Model 215963, Series A 101.6 mm (4 in.) stroke NOTE: T o replace Air Motor 215963, order Motor Replacement Kit 223099. See manual 307977 for parts.
307456 2 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 5 . . . . . . . . . . . . . . . . . .
307456 3 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
307456 4 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed/dispensed.
307456 5 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
307456 6 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5. Relieve the Pressure before you check or service any system equipment. NOTE: Check all other possible problems and solu- tions before disassembling the pump.
307456 7 Service NOTE: Repair Kit 214584 is available. For best results, use all the new parts in the kit, even if the old parts look good. Parts included in the kit are marked with a dagger , for example (6†), in the text and illustrations.
307456 8 Service 03654 Piston Detail Use pliers (B) only when removing piston. Do not use when tightening piston to rod (23). 220168 Air V alve and Piston Assembly (1 1) Piston Rod and Base 1 2 Apply Sealant T orque to 1.3–1.6 N S m (10–14 in-lb) *16 *14 27 *13 28 15 *12 1 8 23a 23 20 †9 22 26 7 5 6† 8 B 16* 2 4 C 23 0.
307456 9 Parts 03655B *16 *14 27 *13 28 15 *12 7 5 †6 8 6† 4 20 23 9† 22 1 26 1 2 1 2 Apply Sealant T orque to 1.3–1.6 N S m (10–14 in-lb) 10† 2 3 Ref No.
307456 10 Dimensions Mounting Hole Layout 03652B 201 mm (7.9 in.) 1/4–18 npt(f) 59 mm (2.32 in.) diameter 32 mm (1.26 in.) 16 mm (0.63 in.) 27.71 mm (1.
307456 1 1 T echnical Data Maximum inbound air pressure 12.5 bar (1.25 MPa,180 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air inlet size 1/4 npt (f) . . . . . . . . . . . . . . . . . . . . . .
307456 12 The Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
An important point after buying a device Graco 215963 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco 215963 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco 215963 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco 215963 you will learn all the available features of the product, as well as information on its operation. The information that you get Graco 215963 will certainly help you make a decision on the purchase.
If you already are a holder of Graco 215963, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco 215963.
However, one of the most important roles played by the user manual is to help in solving problems with Graco 215963. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco 215963 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center