Instruction/ maintenance manual of the product System QT 120 Amcor
Go to page of 11
DEHUMIDIFIER QT 120 GB Instruction manual.
2 CONTE NTS Thank you 3 Safety Instructions 3 How it works 5 Placement 6 Operation 7 Emptying the water tank 8 Cleaning 9 Long term storage 9 T rouble shooting 10 T echnical data 10.
3 TH AN K Y OU SAFETY INSTRUCTIONS GB • Remove all packaging materials from the unit, keep it away from babies and small children to avoid the danger of suffocation. • Before inserting the plug make sure that the voltage is within the range indicated on the rating label on the unit.
4 GB Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the power cable wires are frayed or cut When small children may be left unattended If a.
5 GB HOW IT WORKS C ondenser (W armed coil) E vaporater (Cold refrigerated coil) C ompressor Fa n Motor Micro switch W ater tank Dry warmer air Moist air Y our Amcor dehumidifier draws air through two filters onto a refrigerated cold coil.
6 GB PLACEMENT Y our AMCOR dehumidifier will begin to protect your home from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture travels throughout your home, in the same way that cooking smells spread to every room in the house.
7 GB CONTROL PANEL AND OPERA TION 1 2 3 4 ON and humidity level control [2] T urn the humidity control knob to the OFF position before connecting to the mains. Set the humidity controller to the required humidity level or fully clockwise to the maximum position for continuous working.
8 When the water tank is full, the unit will switch off automatically and the indicator [4] will illuminate. At this time, please empty the water tank as follows: • Slowly slide out the tank squarely using the recess at the bottom of the water tank as shown.
9 Always unplug the unit from the mains before carrying out any maintenance or cleaning the unit. Cleaning the body Only use a soft cloth to wipe the unit clean. Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other harmful cleansing solutions.
10 GB TROUBLE SHOOTING TECHNICAL DA T A Model QT 120 Power supply 220 - 240 V / 50 Hz Power consumption (at 27 °C, 90% RH) W 195 Moisture removal (at 32 °C, 90% RH) L/24h 12 Refrigerant R-134A Refri.
QT 120 China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.
An important point after buying a device Amcor System QT 120 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Amcor System QT 120 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Amcor System QT 120 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Amcor System QT 120 you will learn all the available features of the product, as well as information on its operation. The information that you get Amcor System QT 120 will certainly help you make a decision on the purchase.
If you already are a holder of Amcor System QT 120, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Amcor System QT 120.
However, one of the most important roles played by the user manual is to help in solving problems with Amcor System QT 120. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Amcor System QT 120 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center