P R ODUCT S PECIFICA TIONS SS-CKF50 www .goodmanmfg.com 11/07 Supersedes 6/07 50 H Z , 2- TO 6-T ON [1 0.6 K W TO 2 0.5 K W] C OOLING -O NL Y C ONDENSING U NIT This 50-Hz split system air conditioner allows for ground-level or rooftop applica tions and has been tested for optimum perf ormance by an independent third party .
2 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS D IMENSIONS P ERFORMANCE R A TINGS Outdoor Unit Indoor Unit Cooling Capacity (BTU/h) dBs T otal Sensible EER¹ kWI² CKF24-2* A24-00-2RA 24,000 16,800 9.0 2.66 76 CA*F1824*6* 24,600 17,400 9.0 2.
SS-CKF50 www .goodmanmfg.com 3 P RODUCT S PECIFICA TIONS S PECIFICA TIONS CKF24-2* CKF36-2* CKF36-5* CKF48-5* CKF60-5* CKF70-5* Capacities Nominal Cooling (BTU/h) 24,600 34,000 34,000 44,000 55,000 64,000 EER¹ 9.0 9.0 9.0 9.0 9.0 9.0 Decibels 76 76 78 78 80 80 Compressor RLA 12.
4 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 5 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF24-2* / A2 4-00-2RA ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
6 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF3 6-2* / A3 6-00-2 Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 7 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF3 6-2* / A3 6-00-2 ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
8 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF3 6- 5* / AR3 6-00-2 Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 9 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF3 6- 5* / AR3 6-00-2 ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
10 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF48- 5* / A48-00-2 Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 11 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF48- 5* / A48-00-2 ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
12 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF60- 5* / A60-00-2 Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 13 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF60- 5* / A60-00-2 ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
14 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF7 0-5* / A60-00-2 Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 821 MBh 59.
SS-CKF50 www .goodmanmfg.com 15 P RODUCT S PECIFICA TIONS E XP ANDED C OOLING D ATA — CKF7 0-5* / A60-00-2 ( CONT .) Outdoor Ambient T emperature 65ºF 75ºF 85ºF 95ºF 105ºF 1 15ºF Entering Indoor Wet Bulb T emperature IDB Air fl ow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 821 MBh 61.
16 www .goodmanmfg.com SS-CKF50 P RODUCT S PECIFICA TIONS Q UALITY M AKES THE D IFFERENCE ! All of our systems are designed and manufactured with the same high-quality standar ds, reg ardless of size or ef fi cienc y .
An important point after buying a device Goodman SS-CKF50 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Goodman SS-CKF50 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Goodman SS-CKF50 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Goodman SS-CKF50 you will learn all the available features of the product, as well as information on its operation. The information that you get Goodman SS-CKF50 will certainly help you make a decision on the purchase.
If you already are a holder of Goodman SS-CKF50, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Goodman SS-CKF50.
However, one of the most important roles played by the user manual is to help in solving problems with Goodman SS-CKF50. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Goodman SS-CKF50 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center