Instruction/ maintenance manual of the product P221 Giant
Go to page of 16
Seri e s P 200A Updated 6/00 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P223 Contents: Installation Instructions: page 2 Pump S.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 1725 1.7 1.2 1.8 2.4 3.0 3000 3.0 2.1 3.1 4.2 5.2 3200 3.2 2.2 3.3 4.4 5.5 3450 3.
4 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
5 Specifications Model P219A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
7 Specifications Model P221A V olume ................................................................................................... Up to 2.21 GPM Discharge Pressure ................................................................................
8 Specifications Model P223A V olume ................................................................................................... Up to 3.0 GPM Discharge Pressure ................................................................................ Up to 3000 PSI * Inlet Pressure .
9 ITE M PART NO. DESCRIPTION QTY. 16A 06562 Plunger Base (P223 Only) 3 16B 08455 Plunger Pipe (Excluding P223) 3 16B 07778 Plunger Pipe (P223 Only) 3 16C 08456 Tension Screw 3 16D 07676 Copper Gasket .
10 Exploded View - P200A Series.
11 P200A SERIES REPAIR KITS Plunger Packing Kit Part # 09164 (Excluding P223) Item # Qty. Part # Description 23 3 08477 V-Sleeve, weep 23A 3 08087 V-Sleeve, brown 24 3 07904 Pressure Ring Plunger Packing Kit Part #09525 (P223 Only) Item # Qty. Part # Description 23 6 06315 V -Sleeve 24 3 06920 Pressure Ring Oil Seal Kit Part # 09144 Item # Qty.
12 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
13 Reassembly sequence of the P200A series pump 1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. 2) Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly.
14 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/or the Delivery Drops Water in crankcase Noisy Operation Rough/Pulsating Operation with Pressure Drop Pressure Drop at Gun Excessive Leakage Hig.
15 NOTES P200A DIMENSIONS (inches).
GI ANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
An important point after buying a device Giant P221 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Giant P221 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Giant P221 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Giant P221 you will learn all the available features of the product, as well as information on its operation. The information that you get Giant P221 will certainly help you make a decision on the purchase.
If you already are a holder of Giant P221, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Giant P221.
However, one of the most important roles played by the user manual is to help in solving problems with Giant P221. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Giant P221 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center