Instruction/ maintenance manual of the product P206 Giant
Go to page of 11
Contents: Installation Instructions: page 2 Pump Specifications: pages 3 - 5 Exploded View: page 6 Parts List: page 7 Kits & Torque Specifications: page 7 Repair Instructions: pages 8 - 9 Trouble .
2 INST ALLA TION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
HORSEPOWER RA TINGS: The rating shown are the power requirements for the pump . Ga s engine power outputs must be approximately twice the pump power requirements shown above. W e recommend a 1.15 service factor be specified when selecting an electricmotor as the power source.
P2 06 HORSEPOWE R REQUIREMEN TS R PM G PM 1000 PSI 1500 PSI 2000 PS I 2500 P SI * 250 0. 11 0. 1 0.1 0. 2 0.2 500 0. 21 0. 1 0.2 0. 3 0.4 1 000 0.43 0. 3 0.4 0. 6 0.7 1 750 0.76 0. 5 0.8 1. 0 1.3 3 000 1.30 0. 9 1.3 1. 8 2.2 3 200 1.40 1. 0 1.4 1. 9 2.
P2 08 H O R SEPO WER REQUIREMENTS R PM GP M 1000 PSI 1500 PSI 2000 PSI 2500 PSI * 250 0. 14 0.1 0. 1 0.2 0.2 500 0. 29 0.2 0. 3 0.4 0.5 10 00 0.57 0.4 0. 6 0.8 1.0 17 50 1.00 0.7 1. 0 1.4 1.7 30 00 1.60 1.1 1. 7 2.2 2.8 32 00 1.80 1.2 1. 9 2.5 3.1 34 50 1.
6 Exploded V iew - P205/206/208.
Position Item# Description T orque Amount 32 07928 V alve Plug 33 or 59* (ft.-lbs.) 34 08316 Hex Head Cap Screw , V alve Casing 105 (in.-lbs.) 7 ITEM PART NO.
8 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly . This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
9 Reassembly sequence of the P205/206/208 PUMPS 1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. Contact Giant for assistance with the reassembly of the gear end. 2) Replace seal case (20) with o-rings (21) over plungers.
REMEDY Replace packing seals Replace spring Tighten or Replace belt Replace nozzle Clean valve assembly Clean strainer Repair/Replace hose Clean, Reset, and Replace worn parts Check suction lines on i.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
An important point after buying a device Giant P206 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Giant P206 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Giant P206 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Giant P206 you will learn all the available features of the product, as well as information on its operation. The information that you get Giant P206 will certainly help you make a decision on the purchase.
If you already are a holder of Giant P206, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Giant P206.
However, one of the most important roles played by the user manual is to help in solving problems with Giant P206. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Giant P206 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center