Owner’s Manual Questions? Help is just a moment a wa y! Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT W eb: www .g enerac-por tables.com or www .briggsandstratton.com Model No . 1646-3 (5,550 W att A C Generator) Manual No. 193711GS Re vision 4 (11/29/2004) Safety Rules .
2 WheelHouse™ 5550 W att Generator EQUIPMENT DESCRIPTION Read this manual car efully and become familiar with your g enerator . Know its applications, its limitations and any hazar ds in volved. The generators are an engine–driv en, r evolving field, alternating curr ent (AC) generator .
WheelHouse™ 5550 W att Generator 3 • When using generator for backup pow er , notify utility company . Use appr oved transfer equipment to isolate generator from electric utility . • Use a ground cir cuit fault interrupter (GFCI) in any damp or highly conductiv e area, such as metal decking or steel work.
4 WheelHouse™ 5550 W att Generator • Use generator only for intended uses. • If you ha ve questions about intended use, ask dealer or call the Generac generator helpline at 1-800-270-1408. • Operate generator only on lev el surfaces. • DO NO T expose generator to excessiv e moisture, dust, dir t, or corr osive vapors.
WheelHouse™ 5550 W att Generator 5 KNO W Y OUR GENERA T OR Read this o wner’ s manual and safety rules before operating y our generator . Compare the illustrations with y our generator , to familiarize yourself with the locations of various contr ols and adjustments.
6 WheelHouse™ 5550 W att Generator ASSEMBL Y Y our generator requir es some assembly and is ready for use after it has been properl y ser viced with the recommended oil and fuel. If you ha v e any pr oblems with the assembly of y our generator , please call the generator helpline at 1-800-270-1408 .
WheelHouse™ 5550 W att Generator 7 is relie ved by turning the v ent knob fully counterclockwise or loosening and retightening the fuel ca p/gauge . When installing the tank on your generator , reliev e tank pressure befor e tightening the four large plastic wing nuts.
8 WheelHouse™ 5550 W att Generator USING THE GENERA T OR System Gr ound The generator has a system ground that connects the generator frame components to the ground terminals on the A C output receptacles. The system ground is connected to the A C neutral wire (see “Equipment Description”, earlier in this manual).
WheelHouse™ 5550 W att Generator 9 OPERA TING THE GENERA T OR Star ting the Engine Disconnect all electrical loads from the generator . Follow these start instruction steps in numerical order : 1.
10 WheelHouse™ 5550 W att Generator RECEPT A CLES 120 V olt A C , 20 Amp , Duplex Receptacle Each receptacle (Figur e 9) is protected against o verload by a push–to–reset cir cuit break er . Use each receptacle to operate 120 V olt A C , single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.
WheelHouse™ 5550 W att Generator 11 DON'T O VERLO AD GENERA T OR Capacity Y ou must mak e sure your generator can suppl y enough rated (running) and surge (starting) watts for the items you will pow er at the same time . Follow these simple steps: 1.
12 WheelHouse™ 5550 W att Generator SPECIFICA TIONS Maximum Surge W atts . . . . . . . . . . . . . . . . . .8,550 watts Continuous W attage Capacity . . . . . . . . . . . .5,550 watts P ower Factor . . . . . . . . . . . . . . . . . . . . . . . . . .
WheelHouse™ 5550 W att Generator 13 ST ORA GE The generator should be started at least once every seven da ys and allowed to run at least 30 min utes. If this cannot be done and you m ust store the unit for mor e than 30 da ys, use the follo wing guidelines to prepare it f or storage.
14 WheelHouse™ 5550 W att Generator TR OUBLESHOO TING Pr oblem Cause Solution Engine is running, but no A C output is a vailable. 1. Circuit br eak er is open. 2. P oor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator .
WheelHouse™ 5550 W att Generator 15 NO TES.
GENERA C POR T ABLE PRODUCTS O WNER EQUIPMENT W ARRANTY POLICY Effectiv e Nov ember 1, 2004 W ARRANTY PERIOD* * The warranty period begins on the date of pur chase by the first retail consumer or commer cial end user , and continues for the period of time stated in the table abov e .
An important point after buying a device Generac 1646-3 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Generac 1646-3 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Generac 1646-3 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Generac 1646-3 you will learn all the available features of the product, as well as information on its operation. The information that you get Generac 1646-3 will certainly help you make a decision on the purchase.
If you already are a holder of Generac 1646-3, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Generac 1646-3.
However, one of the most important roles played by the user manual is to help in solving problems with Generac 1646-3. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Generac 1646-3 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center